Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

Mine equipment operation safety risk points and prevention and control

来源: | 作者:佚名 | 发布时间 :2023-11-28 | 458 次浏览: | 🔊 Click to read aloud ❚❚ | Share:

① Mine disk saw operation requirements risk points and prevention and control. Check the condition of the equipment before running the circular saw, find out the security risks of the equipment in time, and handle them in time to ensure the safety of the equipment before operating. Mine circular saw controls the depth of each cut to prevent the phenomenon of card sawing from causing safety accidents. The speed of the circular saw in mine should be controlled to prevent the phenomenon of stuck sawing due to the excessive speed of the circular saw. Some circular saws are operated by people standing on them, and card saws pose a serious threat to human life safety when they occur. Often check the firmness of the teeth of the disc saw, and the loose ones are firmly welded. Saw blade teeth damaged seriously, should be replaced in time. During the operation of the circular saw in the mine, it is strictly forbidden to stay in the working area for a long time to prevent the injury of the circular saw to the people around.

 

② Mine disk saw blade installation risk points and prevention and control. The installation of the mine disc saw should be carried out by professional maintenance personnel. When installing a circular saw, ensure that the nut is tight.

③ Risk points and prevention and control of raw material and plate loading and unloading. After the disc saw is finished cutting the waste material or the plate, the waste material and the plate should pay attention to safety during the unloading process. If the unloading method is improper or careless, it is easy to cause accidents and even lead to casualties.

④ Mine disk saw equipment failure treatment. Mine circular saw failure, should be by professional maintenance personnel to check the circular saw, deal with equipment failure, to ensure the safety of equipment.

⑤ Safety precautions when the mine disk saw is shifted. Mine circular saws need to move frequently as the mining height changes. The disk saw should be responsible for the shift, if necessary, the development of safety measures plan, strictly according to the safety measures plan for the shift work, to ensure the safety of equipment and personnel during the shift of the disk saw.

(4) Mine diamond beaded rope operation safety risk and prevention and control

Mine diamond beaded rope saw injury accidents have been heard of several, the most serious accident has occurred in Italy Carrara white mine. It is said that the broken diamond beaded rope saw drove the cracked stone to hit the staff at the working face, and the mine stopped production for a long time and suffered huge losses. Domestic mines have also occurred diamond bead rope broken throw injury accident. With the popularity of diamond beaded rope saw, stone production enterprises should pay attention to the control of safety risk points of diamond beaded rope saw operation and reduce mine production accidents.

Mine diamond beaded rope saw operation safety risk control should pay attention to the following aspects:

① Diamond beaded rope installation must be firm. Diamond beaded rope running process suddenly thrown out to produce a huge force, if hit people will be killed immediately. Therefore, the installation of diamond string must be firm.

② Diamond beaded rope to control the number of joints. After the diamond beaded rope is broken, it will be connected with special joints to continue to use, but with the increase of the number of joints, the safety risk of diamond beaded rope saw is also increasing, which also poses a great danger to the operator of diamond beaded rope saw. Therefore, the number of diamond beaded rope joints must be controlled in a range that can ensure the strength limit of diamond beaded rope, and the number of diamond beaded rope joints cannot be increased without restriction in order to save mining costs.

③ The diamond beaded rope joint should be firm. The diamond beaded rope joint must be firm to ensure that the diamond beaded rope will not detach from the joint during operation. Apply appropriate pressure to the joint when connecting the rope. The pressure is small, the connection of the joint is insufficient, and it is easy to get away from the joint; The pressure is large, the pressure will break the joint, the strength of the joint is greatly reduced, and the diamond beaded rope is easy to pull away from the joint.

④ Diamond beaded rope is forbidden to be installed in a distorted state, when the diamond beaded rope is in a distorted state in production, the diamond beaded rope should be restored to a straight state with the force in the opposite direction of the distorted state. If the diamond beaded rope is twisted for a long time, the diamond beaded rope is easy to break during operation.

③ Diamond beaded rope running speed control. The reasonable running speed of the diamond beaded rope can not only ensure the safety of the operation of the equipment, but also reduce the broken rope caused by the diamond beaded rope running too fast. Diamond beaded rope operators cannot increase the running speed of diamond beaded rope in order to desperately pursue high output.

  • ABB DSAI130DK01 3BSE020828R1 Analog Input Module
  • Parker 466966-0001-3820 Industrial Component Data
  • PARKER ZETA6104 Microstepping System
  • PARKER COMPAX 2500S/F3 Servo Drive Manual Details
  • PARKER CX-DH Indexer Drive Technical Specifications
  • PARKER 6K8 Motion Controller Features and Specifications
  • PARKER EVM32-BASE I/O Module Base Technical Specification
  • ABB Pb PN-112718 Digital Input Module
  • Pb PN-45734 PN-73899 Industrial Automation Module
  • Control Techniques Pb PN-40856 Industrial Control Module
  • Pb PN-104412 4002910956 Industrial Control Module
  • Siemens Pb PN-41513 Industrial Ethernet Module
  • Pelco PA30-0065-00-A1 PTZ Decoder Module
  • Pentek FILTER 3F11 800000919 Pleated Filter Cartridge
  • Pepperl+Fuchs RSD-TI-EX8 Temperature Input Module
  • PERITEK AC7-00712-1113 Industrial Interface Module
  • PFEIFFER EVR116 Vacuum Control Module
  • Pepperl+Fuchs RSD-CI-EX8 Hazardous Area Interface Module
  • PEPPERL+FUCHS 2108HAT Intrinsic Safety Barrier Module
  • Philips 958481320201 PROC+ Processing Unit
  • Philips 958481321300 PSB Power Supply Board
  • Philips 958481321220 PD208 Power Module
  • PHILIPS 958481321200 PD216 Control Module
  • PHILIPS 958481320201 PROC PLUS Control Module
  • Philips 958481320400 PIF Interface Module
  • Philips 958481320100 LCB Control Board
  • PHILIPS 958481223220 Industrial Control Module
  • PHILIPS 958481223223 Industrial Control Module
  • PHILIPS 958481321300 Industrial Control Module
  • PHILIPS SCM040 Digital Output Synchronization Module
  • PHILIPS DSI020 Data Storage Interface Module
  • PHILIPS OPM010 Optoelectronic Control Module
  • PHILIPS VBM010 Industrial Automation Module
  • PHILIPS VBM030 Turbine Supervisory Instrumentation
  • PHILIPS PR1613 Industrial Control Module
  • PHOENIX PATG1/23 1013847 Ground Terminal Block
  • Phoenix Contact IB ST 24 AI 4/SF Analog Input
  • Phoenix Contact OPC5315-004-AB Industrial PC
  • Phoenix Contact UMK-SE11.25-1 Side Element
  • PHOENIX 2961192 Relay Module
  • PHOENIX IB ST ZF 24 AI 4/SF Analog Input Module
  • Phoenix Contact PLC-BSC-24DC/21 Relay Base
  • Phoenix Contact UK6N Feed-Through Terminal Block
  • Phoenix Contact UK4-T Disconnect Terminal Block
  • Phoenix UK3N Screw Terminal Block
  • Phoenix QUINT-PS-100-240AC/10 Power Supply
  • Phoenix QUINT PS-100-240AC/24DC/10 Power Supply
  • Phoenix UT 6-HE SI Surge Protection Terminal Block
  • Phoenix UT 4-MTD Feed-through Terminal Block
  • Phoenix UT 4-HE SI Surge Protection Terminal Block
  • Phoenix IBS 24BK-I/O-T Bus Coupler
  • Phoenix Contact HDFK4 High-Current Terminal Block
  • PHOENIX ST-SI-UK4 Fuse Terminal Block
  • PHOENIX FLMC10BASE-T/FO G850 Fiber Media Converter
  • PHOENIX CONTACT QUINT-PS-100-240AC/24DC/40 Power Supply
  • PHOENIX CONTACT QUINT-DIODE/40 Redundancy Module
  • Phoenix Contact 2884208 Wireless I/O MUX
  • Photonetics 3646 HE 1540 Tunable Laser Source
  • PI C-663.12 Mercury Multi-Axis Step Motor Controller
  • PI C-663.10 Mercury Step Motor Controller
  • Pillar CB6687-2L Industrial Communication Board
  • Pilz DE-106712 A.F.051.5/01 Safety Module
  • Pilz 680003 Safety Relay Module Set
  • Pilz 301140 PNOZ X3 Safety Relay
  • Pilz P1U-1NB Safety Relay
  • Pioneer PM3398B-6-1-3-E Power Supply
  • Pioneer Magnetics PM3326B-6-1-2-E Power Supply
  • Pioneer Magnetics HYRSP-1500-56 Power Supply
  • Pioneer Magnetics PM3398B-6-1-3-E Power Supply
  • Pioneer Magnetics PM3328BP-6 Power Supply
  • Potter & Brumfield SDAS-01-7Y2S1024 Relay
  • Powec PMP10.48 SIC High-Efficiency Rectifier
  • Powerbox PU200-31C Industrial DC-DC Converter
  • PIONEER MAGNETICS PM3398BP-6-1-3-E Power Supply Module
  • PIONEER MAGNETICS PM1253AL-6-3-Z03 Power Supply Module
  • Powerex PD411811 Rectifier Diode Module
  • Power-One MAP55-1024 AC-DC Power Supply
  • ProSoft MVI56-MDA4 ControlLogix Multi-Protocol
  • POLYSPED PRD2-200 Industrial Drive Module
  • P-OPEN P-OPEN-P4-150 PAC-OP150 Operator Panel
  • ABB Processor 958481321210 350211080320 Rugged CPU
  • ABB Processor 958481320201 350211080460 Safety CPU
  • ABB Processor 958481321200 350211080320 CPU Module
  • ABB Processor 958481321220 350211080320 CPU Module
  • ABB Processor 958481320100 350211080090 CPU Module
  • Pro-Face PL5901-T42-24V HMI Touch Panel
  • PROFIBUS PB3-VME-1-E V1.2.2 Interface Card
  • PROMESS 850040060P Force Displacement Monitor
  • PROSOFT AN-X2-AB-DHRIO DH+ and Remote I/O Gateway
  • PROSOFT RLX2-IFH24E Industrial Wireless Radio Module
  • PROSOFT 5202-DFNT-MCM4 DF1 to EtherNet/IP Gateway
  • PROSOFT PLX35-NB2 EtherNet/IP to Modbus TCP Gateway
  • ProSoft 5201-MNET-MCM-WEB Modbus TCP/Serial Gateway
  • ProSoft 5304-MBP-PDPMV1 Modbus Plus to PROFIBUS DP Master
  • ProSoft 5302-MBP-MCM4 Modbus Plus to Modbus Master/Slave
  • ProSoft 5301-MBP-DH485 Modbus Plus to DH485 Gateway
  • ProSoft 6104-WA-PDPM Wireless PROFIBUS DP Master
  • ProSoft MVI56-LTQ ControlLogix Limitorque Master
  • Prosoft 5304-MBP-PDPM PROFIBUS Master Module
  • Prosoft 1452-25M Relay Output Module
  • Prosoft MVI56-MNETR Modbus TCP/IP Module
  • Prosoft MVI69L-MBS Modbus Serial Module
  • Prosoft PLX32-EIP-SIE Ethernet Gateway
  • Prosoft MVI56-PDPS PROFIBUS DP Slave Module
  • Prosoft PMF1327205 Gateway Module
  • Prosoft PMF1216D61 FOUNDATION Fieldbus Module
  • PROSOFT MVI56-GSC Generic Serial Communication Module
  • PROSOFT 5601-RIO-MCM Remote I/O Communication Module
  • PROSOFT 1454-9F Communication Interface Module
  • PROTECH SYSTEMS PBI-6SA Industrial Single Board Computer
  • PRSTECH DMP10.24-20 DIN-Rail Power Supply
  • PRT PSA300R-81 Industrial Power Supply Module
  • PULS SLA8.100 AS-Interface Power Supply
  • QSI QTERM-K65 Industrial Operator Interface
  • R-2528Z R-2528Z Industrial Specialized Component
  • Radisys SBC486DX66 Single Board Computer
  • Radisys EPC-5 with EXM-13 Embedded System
  • Radisys EPC-16 Embedded Computer
  • Ramix PMC676TX PMC Ethernet Adapter
  • Ramix PMC008A PMC-to-VME Adapter
  • Ramix PMC237C-008EMI PMC Carrier
  • Ramix PMC661J PMC Carrier Board
  • Renata CR2450N Lithium Battery
  • Renault Circuit CU-8593-IND.A Control Module
  • Reotron 567LH-DP24 Voltage Regulator
  • RIFA IC693PWR321U GE Fanuc Series 90-30 Power Supply
  • RKC REX-B871NN-CS1B Intelligent Controller
  • RKC B871-RCU Digital Temperature Control Unit