Bosch Rexroth D8_5 EDD-XZ Directional Valve Selection and Configuration Guide

F: | Au:FANS | DA:2026-11-26 | 11 Br: | 🔊 点击朗读正文 ❚❚ ▶ | Share:

Bosch Rexroth D8_5 (EDD-XZ) 4/3 and 4/2 on-off directional valve component selection, configuration, installation and maintenance guide

Product Overview: Stacked valve type wet needle electromagnetic directional valve component

The D8_5... (EDD-XZ) series launched by Bosch Rexroth Oil Control is a 4/3 and 4/2 on-off directional valve component with specifications 8 (Size 8) and series 00, which can be equipped with or without a secondary relief valve and LS (load sensitive) channel. It is a slide valve directional valve directly driven by an electromagnet, designed with removable coils; In the power-off state, the control valve core is held in the central position by the reset spring.

Core specification highlights:

Working pressure: The maximum pressure on the pump side P port is 310 bar (4500 psi), the maximum pressure on the actuator side A/B ports is 380 bar (5500 psi), and the maximum pressure on the T port is 250 bar (3625 psi) - A/B port pressure is higher than P port, which is a typical requirement for load holding applications. When selecting, it is necessary to check the pressure on each of the three ports separately;

Maximum flow rate of 80 l/min (21.1 gpm);

Oil port connection: three types: G 1/2 (DIN 3852), SAE 10 (7/8-14 UNF), and flange connection (A-B-T);

The valve core position sensor is optional (see RE 18300-30).

The wet pin tubular structure is used for DC coils, with a mechanical push rod for manual emergency response; Galvanized surface. The coil can rotate 180 ° around the needle tube for installation and wiring, and can be powered by AC electricity through a special connection with a rectifier (RAC). Manual emergency (button type/screw type) is optional; Multiple plug-in connectors are available (see order details).


Model code and configuration matrix

The 11 digit model code covers five configuration dimensions:

Field 05 Valve core variant (core selection item):

The median functional variants include B201/E201/K201/E2R1 (O-type with P, A, B connected to T, etc.), B301/E301/K301/X301/Y301 (A-side spring+median), B401/E401/K401/X401/Y401 (B-side) - covering more than ten median functions such as O-type, H-type, Y-type, K-type, etc;

3_ (4/2 only driven on side A): single electromagnet with two position four-way connection;

4_ (4/2 only for B-side drive): Mirror configuration.

The configuration of the electromagnet determines the default oil circuit of the valve when it is in neutral power-off position - this is the first decision point in safety circuit design.

Field 06 Voltage power supply (8 types): Wireless coil 00; 12V DC(OB)、13V DC(AD)、24V DC(OC)、27V DC(AC)、48V DC(OD); And 24V AC (21.5 DC, OV), 110V AC (98 DC, OW), 230V AC (207 DC, OZ) rectified by RAC. Voltage compatibility is subdivided according to coil configuration - for example, 12V DC is only available for some configurations, and the selection must check the "●/-" availability matrix.

Field 07 Electrical Connections (5 types): Wireless Circle 00; Equipped with coils but without DIN EN 175301-803 mating connector 01; Equipped with coil and bidirectional diode, without vertical Amp Junior pairing connector 03; Equipped with coil and bidirectional diode, without DEUTSCH DT04-2P mating connector 07; Lead wire with coil and bipolar sheath, 350 mm long, 31. The ordering code for connectors can be found in RE 18325-90.

Field 08 oil port: G 1/2 (code 2), SAE 10 (code D), flange connection A-B-T (code M).

Field 09/10 Secondary Valve (Port A/B): No Secondary Valve 0; Anti cavitation function valve VUM (code 1, characteristic curve see RE 18329-51); Direct acting relief valve VMA with anti cavitation function (see pressure gauge for setting code and RE 18329-11 for characteristic curve). Key rule: Using a secondary valve for one oil port means that both oil ports must use a secondary valve - single-sided configuration is not allowed. The maximum flow rate of VMA direct acting relief valve is 30 l/min (7.93 gpm), and circuits exceeding this flow rate cannot use VMA for full flow relief. Set the pressure from 20 bar (A gear, 290 psi) to 250 bar (X gear, 3626 psi) in 24 steps, increasing step by step according to the code letters A-X.

Field 11 option: Button type manual emergency 0P (M93300043, press fit on coil locking ring nut); Screw type manual emergency 0F (R933007215, screw in the needle tube with a torque of 6-7 Nm instead of the coil ring nut).

Configuration 03: Standard 0; Load sensitive channel 4- LS type (=4 symbol) adds LS port outside of P/T, and the flange connection size is different (the flange specifications of the LS channel flange and ED intermediate component are different from the standard type).


Functional principle: Eight element decomposition and emergency operation

The valve component consists of nine key parts (functional diagram number): stackable shell (1)+control valve core (2)+valve core thrust washer (3)+reset spring (4)+electromagnet (5)+coil locking ring nut (6)+emergency sales (7)+secondary plug-in valve (8).

Working principle: The spring chamber is connected to the fuel tank port. When powered on, the electromagnetic force pushes the control valve core from the center position to the desired position, achieving the flow of P → A (B → T) or P → B (A → T); After power failure, the reset spring presses the thrust washer (3) back into the housing, and the valve core returns to the center position. Each coil is locked to an electromagnetic iron pipe (Ø 19 mm) with a ring nut (6). Promotion (7) is used for manually pushing the valve core in emergency situations where the electromagnet cannot be powered on (such as voltage shortage) - this is a key design for power outage rescue.

Secondary plug-in valve (8): designed for fast response and stable pressure control, with built-in reverse flow check valve to prevent cavitation - preventing A/B ports from vacuuming in load driven actuators (such as negative load lowering conditions). The adjustment point of the secondary overflow valve is a hexagonal 6mm screw with a torque of 25-30 Nm.

Technical data and oil requirements

Project values

Double solenoid valve weight 3.00 kg (6.61 lbs)

The weight of a single solenoid valve is 2.35 kg (5.18 lbs)

Environmental temperature (NBR seal) -20...+50 ℃ (-4...+122 ℉)

Oil temperature (NBR seal) -20...+80 ℃ (-4...+176 ℉)

Viscosity range 5... 420 mm ²/s

Voltage tolerance nominal voltage -10%...+10%

Continuous work schedule (when the ambient temperature is ≤ 50 ℃)

The upper limit of coil wire temperature is 150 ℃ (302 ℉)

Insulation level H

Low Voltage Directive Compliance LVD 73/23/EC (2006/95/EC), 2004/108/EC

Coil weight (EN 175301-803 connection) 0.5 kg

Oil and cleanliness: Suitable for mineral oil-based HL (DIN 51524 Part 1) and HLP (Part 2) hydraulic oils; Environmentally friendly oils (plant-based or polyethylene glycol based) should be consulted. Triple Red Line of Pollution Level: ISO 4572 β ₓ ≥ 75 X=12... 15, ISO 4406 class 20/18/15, NAS 1638 class 9- Consistent with the 20/18/15 target of Rexroth Industrial Hydraulic Systems. Special specification applications require consultation with the manufacturer.


Quick check of coil electrical parameters (basis for selecting power supply and fuse)

Code Voltage Voltage Type Power Consumption W 100% Current A 20 ℃ Coil Resistance Ω

OB 12 DC DC 36 3.00 3.97

AD 13 DC DC 36 2.77 4.68

OC 24 DC DC 36 1.53 15.67

AC 27 DC DC 36 1.32 20.42

OD 48 DC DC 36 0.75 63.6

OV 24+RAC(21.5 DC) AC 36 1.70 12.61

OW 110+RAC(98 DC) AC 36 0.37 261

OZ 230+RAC(207 DC) AC 36 0.17 1163

All coils have a unified power consumption of 36 W; AC power supply is only available through RAC rectification connection (the valve is essentially a DC coil). Coil material number matrix (16 items): OB01(R933000063)、OB03(R933000065)、OB07(R933000068)、OB31(R933000064)、AD01(R933000069)、AD07(R933000073)、OC01(R933000076)、OC03(R933000071)、OC07(R933000075)、OC31(R933000070)、AC01(R933000077)、AC07(R933000074)、OD01(R933000078)、OV01(R933000079)、OW01(R933000080)、OZ01(R933000081)—— The replacement of spare parts should correspond accurately to the code and connector type. The 12V and 13V coils with similar appearance are not interchangeable (resistance 3.97 Ω vs 4.68 Ω, incorrect installation will cause current overload).


Characteristic curve and performance limit (graded by valve core variant)

Pressure drop characteristics (measured at ISO-VG32 oil 45 °± 5 ℃, ambient 20 ℃): P>A, P>B, A>T, B>T correspond to curves 1-6 for each of the four pathways, mapped according to valve core variants - B201/B301/B401 full pathway curve 4; E201/E301/E401 are P>A/P>B curve 3, A>T/B>T curve 5; K201/K301/K401 is 3/3/5/2; E2R1 is 3/6/5/−; X301/X401 is 2/2/5/5; Y301/Y401 is 2/2/1/1 (the lowest pressure drop group in the entire pathway). Δ p from 3 bar (50 psi) to 18 bar (261 psi) corresponds to a flow rate of 0-80 l/min.

Performance limits (P>A and B>T symmetrical flow area bidirectional measurement): B201 series has curve 1 (highest load), X301/X401 curve 2, K201 series has E2R1 curve 3, E201 series curve 4, Y301/Y401 curve 5 (lowest load). Key Warning: Performance limits may change under special circuit connections - Asymmetric area applications (such as differential cylinder circuits) must recalculate the limit curve based on the actual path.


Dimensions and installation specifications

The total length of the dual solenoid valve is 253.6 mm (9.98 in), and the single-sided solenoid section is 78.7 mm (3.1 in); Valve body width 96.1 mm (3.78 in); Needle segment Ø 19 mm, length 26.5 mm; flange width 78.5 mm (3.09 in) x height 43.5 mm.

Key tightening torque:

Coil locking ring nut (Ø 26.5 mm): 5 Nm ± 10% - damaged needle tube due to over tightening, coil rotation displacement due to over loosening;

Secondary overflow valve adjustment screw (hexagonal 6mm): 25-30 Nm;

Flange connection M6 bolts (4 pieces, equipped with secondary flange components): minimum strength grade DIN8.8, torque 9-10 Nm;

Screw type manual emergency 0F: 6-7 Nm screw into the needle tube.

Refer to RE 18301-90 for information on pull rods and fastening torque; The flange specifications for coupling with ED intermediate components are shown in Note 3/Note 11 (standard type and LS channel type flanges are different). The P/T O-ring (Note 5) is responsible for sealing during stacked installation, and scratches on the installation surface are the main cause of leakage. Note 9: The required clearance of 12.5 mm for disassembling connectors must be reserved during layout. The A/B ports (Note 7) and identification labels (Note 8) are located on the front of the valve body.


Electrical connection protection level (IP level is the core of on-site reliability)

The protective capabilities of the four connection methods differ significantly:

00 Wireless Circle:——

01 (EN 175301-803, formerly DIN 43650): When the connector with seal is correctly unscrewed, IP 65- note that "correct tightening" is a prerequisite for the IP rating to be established;

03 (Amp Junior vertical connector): IP 65 when the female connector is correctly installed;

07 (DEUTSCH DT04-2P): IP 69 K - the only choice for high-pressure and high-temperature flushing environments (food, outdoor construction machinery) when the female connector is correctly installed;

31 (350 mm bipolar sheath lead): The maximum lead size is 350 mm, and the protection level is determined by the user end connector.

Selection logic: 01/03 in the control cabinet is sufficient; Outdoor or flushing conditions must be 07 (DT04-2P, IP69K); The lead plate 31 is suitable for situations where users need to customize heavy-duty connectors.


Typical application troubleshooting

Troubleshooting direction

Check the resistance of the coil when the valve core does not move/moves slowly (nominal value table at 20 ℃); Voltage tolerance -10%/+10%; RAC rectifier fault (AC power supply type)

Fatigue or fracture of the reset spring (4) that does not return to the neutral position after power failure; Thrust washer (3) stuck

A/B port load holding failure secondary valve (8) setting drift -25-30 Nm adjustment screw reset or change VMA higher gear code

The anti cavitation one-way valve fails due to suction noise during actuator action; VUM secondary valve configuration verification

Emergency power outage requires manual operation to promote (7) mechanical top rod; Or choose the 0P/0F manual emergency option

Coil burnout voltage mismatch (12/13V mixed), continuous operation exceeding the upper limit of 50 ℃ environment, wire temperature exceeding 150 ℃

Leakage of P/T port O-ring damage; Flatness of overlay surface; Tighten the ring nut with 5 Nm

  • Rexroth VCP25.1BVN-003PB-NN-PW Operator Panel
  • Rexroth RKL4305/002.5 Power Cable L=250cm
  • Rexroth MSM031C-0300-NN-M5-MH1 R911344216 Servomotor
  • Rexroth CSH01.1C-SE-EN2 R911335435 Control Unit
  • Rexroth FEM-E-S 25x10RX3-4 R151224013 Ball Screw
  • Rexroth FCS01.1E-W0005-A-04-NNBV Frequency Drive
  • Rexroth 0510-425-009 Hydraulic Gear Pump
  • Bosch Rexroth IndraControl XM42 Controller R911396964
  • Rexroth VT5035-17 R900579497 Valve Amplifier
  • Rexroth FCS01-1EW0015-A-04 R91131106 Frequency Drive
  • Rexroth MSK050B-0600-NN-M1-UG1-NNN Motor
  • Bosch Indramat TBM1.2-40-W1-115 Bleeder
  • Rexroth HCS01.1E-W0028 Compact Converter
  • Rexroth Indramat MAC071B-0-PS-2-C/095-A-0 Motor
  • Rexroth HCS02.1E-W0012-A-03-NNNN Drive Set
  • Rexroth R-IL S3 BK DI8 DO4-PAC Coupler
  • Rexroth HCS01.1E-W0028-A-03-E-S3-EC-NNN Drive
  • Rexroth MSK061C-0600-NN-S1-UG0-NNNN Motor
  • Bosch Rexroth MSM041B-0300-NN-M0-CH0 Motor
  • Rexroth IKG0071-05.0m Servo Motor Cable
  • Rexroth R-IL S3 BK DI8 DO4-PAC Bus Coupler
  • Bosch Rexroth SB301 Tightening Unit 0608701017
  • Rexroth E-003-S-S Tool Cable 0608740220
  • Rexroth MSM020B-0300-NN-M0-CG0 Servo Motor
  • Rexroth IndraControl VEP30.3 Panel PC
  • Rexroth DBETE-62/315G24K31A1V Valve R901029969
  • Rexroth CSH01.3C-ET-ENS-NNN Control Section
  • Rexroth VT3013-37 Amplifier Control Card
  • Rexroth 1-2 TH6 L 162-10/N 05 Joystick
  • Rexroth ESV025 Handheld Nutrunner 0608841037
  • Rexroth RK2 S30 Amplifier Card VT 4224 U 261
  • Rexroth CDB01.1C-SE-ENS R911308279 Control Unit
  • Rexroth VFC3610-0K40-3P4-MNA-7P Inverter 0.4kW
  • Bosch Indramat HCS02.1E-W0028-A-03-NNNN Servo Module
  • Rexroth DKC01.3-040-7-FW EcoDrive R911279426
  • Rexroth HMV02.1R-W0015-A-07-NNN Utility Unit 15kW
  • Rexroth 0 608 830 193 ZSE220 Communication Module
  • Rexroth VT5003 S41 R5 Proportional Amplifier Card
  • Rexroth KSM02.1B-041c-42N-M1-HP0-ET-L3-D7-NN-FW Motor Drive
  • Mannesmann Rexroth VT5005 S16 R1 Valve Amplifier Card
  • Rexroth CFL01.1-R3 Sercos III Interface Module
  • Rexroth CKK-110-NN-1 Linear Axis with MSK040C
  • Bosch Rexroth 047018-104401 Controller Card
  • Rexroth MDSD1K-2X/4 Solenoid Driver Module
  • Rexroth DKC02.3-012-3-MGP-01VRS Servo Drive
  • Rexroth HCS01.1E-W0006 Compact Servo Drive
  • Rexroth NAM1.2-08 Line Former R911246505
  • Rexroth VPB40 Industrial PC Control Cabinet
  • Rexroth FWA-ECODR3-SGP-03-MS Firmware Module
  • Rexroth HEDE10-31 Pressure Switch R901425475
  • Rexroth HM 17-11/315-C/V0/0 Pressure Sensor
  • Rexroth VFC 3610-2K20-3P4-MNA-7P Inverter 2.2kW
  • Rexroth MSK040C-0600-NN-M1-UG1-NNNN Right Angle Geared Motor
  • Rexroth DKC02.3-012-3-MGP-01VRS EcoDrive Cs
  • Bosch Rexroth MSM031C-0300-NN-M0-CH0 Servo Motor
  • Rexroth HCS02.1E-W0012-A-03-NNNN Power Section
  • Rexroth DBDS 20 P18/400V Pressure Relief Valve
  • Rexroth 3460565500 Pneumatic EP Converter Regulator
  • Rexroth VT-SWA-1-12/DFEE Angle Sensor R900913641
  • Rexroth 0-608-830-250 Interface Module SM24V
  • Rexroth MHD071B-035-NP0-UN8 Servo Motor 12Nm 1000rpm
  • Rexroth MKD025B-144-KG0-KN R911263737 Servo Motor
  • Rexroth KCU02.2N-ET-ET*-025-NN-N-NN-NW Control Unit
  • Rexroth MV-VPB40*3-RB001VPB R911337529 Valve Terminal
  • Bosch Rexroth AS 2/R-2200 Drive Module 3842998041
  • Rexroth HMS01.1N-W0036 Power Section
  • Rexroth CKK-145-NN1 Compact Linear Module
  • Rexroth MS2N04-C0BTN-BSDK0-NNNNN-NN Geared Servo Motor
  • Rexroth HCS02.1E-W0028-A-03-NNNN Power Section
  • Rexroth MS2N04-D0BQN-CMSG0-NNNNN-NN Servo Motor
  • Rexroth MSM031C-0300-NN-M0-CH0 Servo Motor
  • Rexroth MKD041B-144-KP1-KN Servo Motor R911262307
  • Rexroth ESA075G Handheld Nutrunner 0608841033
  • Rexroth MSK070D-0450-NN-M1-UP1-NSNN Motor
  • Rexroth CKK-145-NNG1 Linear Kit with HCS02 Drive
  • Rexroth MSK060C-0300-NN-M1-UG0-NNNN Servo Motor
  • Rexroth MKD090B-047-KP1-KS Servo Motor
  • Rexroth MLS140S-3A-0450-NNN Linear Motor
  • Rexroth VPB40.3 Industrial PC R911338689 CB1
  • Rexroth HCS02.1E-W0012 Servo Drive R911313871
  • Rexroth R151349014 R151145672 Ball Screw Assembly
  • Bosch Rexroth CKK-110-NN-1 Compact Module
  • Rexroth MSK060B-0300-NN-M1-UG1-NNNN Servo Motor
  • Rexroth Indramat TBM 1.2-40-W1-024 Servo Bleeder
  • Rexroth MSK040B-0600-NN-M1-UG1-NNNN Servo Motor
  • Rexroth MLS200S-3A-0450-NNN R911299213 Linear Motor
  • Rexroth SB356 Tool Tightening Controller Rack
  • Rexroth MSK050C-0300-NN-M1-UG0-NNNN Servo Motor
  • Rexroth Indramat DKC11.3-040-7-FW Eco Drive
  • Rexroth VT2000 Proportional Amplifier
  • Rexroth VT1118-10 Analog Module
  • Rexroth MSK060C-0600-NN-M1-UP1-NSNN Motor
  • Rexroth MSK060C-0300-NN-S1-UG0-NNNN Motor
  • Rexroth R911173937 IndraControl XM AI1
  • Rexroth R412018225 AES-D-BC-ECAT Module
  • Rexroth CDB02.1B R911338542 Controller Card
  • Rexroth VT-HNC100-2-30/P-I-00/000 Module
  • Bosch Rexroth CSB02.1B R911372549 Control
  • Bosch Rexroth R185321310 Runner Block
  • Rexroth VPB40.3 Industrial PC R911338689
  • Rexroth HNK01.1A-A075-E0106-A-500 Drive Controller
  • Rexroth CSH02.1B-CC-EC-ET-S4-NN-NN-FW Controller
  • Rexroth CSB01.1C-PB-ENS-NNN Control Unit
  • Rexroth MKD041B-144-KP0-KN Permanent Magnet Motor
  • Rexroth SE-B2.020.030-14.000 Servo Motor
  • Rexroth MSK060C-0600-NN-M1-UG0-NNNN Servo Motor
  • Rexroth HCS01.1E-W0018-A-03-B Drive Controller
  • Rexroth 3 842 547 996 IE3 Geared Motor
  • Rexroth CSH01.1C-NN-ENS R911309709 Control Section
  • Rexroth R151349013 Ball Screw Nut
  • Mannesmann Rexroth VT3006-36 Analog Amplifier Card
  • Bosch Rexroth R900086160 PGF1 Gear Pump
  • Bosch Rexroth R911173263 VDP15.3 Touch Display
  • Bosch Rexroth PPC-R22.1 RJ522 Industrial Controller
  • Bosch Rexroth MSK060C-0300-NN-S1-UG0-NNNN Servo Motor
  • Bosch Rexroth R911325068 NYS04.1 Controller
  • Bosch Rexroth R911335439 CSH01.1C Control Unit
  • Bosch Rexroth R917010287 BODAS RC10 Controller
  • Bosch Rexroth R911329791 CSH01.1C Drive Controller
  • Bosch Rexroth R182432310 Runner Block Guide
  • Bosch Rexroth VT-VSPA2-1-11 Amplifier Card R900021909
  • Bosch Rexroth MKD090B-047-KG1-KN Servo Motor
  • Bosch Rexroth LTU350 Servo Amplifier 0608750108
  • Bosch Rexroth 5610102050 Pneumatic Vacuum Regulator
  • Bosch Rexroth VT5041-23/3-OV PLC Control Board
  • Bosch Rexroth VT3015 S10/E Servo Amplifier Board
  • Bosch Rexroth MSK070D-0300-NN-M2-UG1 Servo Motor
  • Bosch Rexroth 3DREP6C-21 Valve R900955887