Bosch Rexroth VDP 16.3/40.3/60.3 Operating Terminal Installation and Troubleshooting Guide

F: | Au:FANS | DA:2026-11-26 | 11 Br: | 🔊 点击朗读正文 ❚❚ ▶ | Share:

Bosch Rexroth IndraControl VDP 16.3/40.3/60.3 Operation Display Terminal Installation Wiring and Fault Handling Depth Guide

Product positioning and scope of application

Rexroth IndraControl VDP 16.3, VDP 40.3, and VDP 60.3 are passive operation and visualization terminals launched by Bosch Rexroth. They do not have computing capabilities and must be used in conjunction with Bosch Rexroth control cabinet PCs (such as VSB 40.3, VSP xx.3, VBP 40.3, VPP xx.3 series) to form a complete PC based operation terminal solution. Typical application areas include handling and assembly systems, packaging and food processing machinery, printing and paper processing machinery, machine tools, and wood processing machinery.

This manual applies to all variants with model codes starting with "VDPxx. 3..." and excluding "... CG..." - models with CG codes are versions built into the system chassis and require separate reference to the corresponding documentation. The supporting documents include VAP 01 power unit (R911339613), VAU 01.1 UPS uninterruptible power supply (R911336867), VAC 01 Y distributor (R911336973), and V series equipment project planning manual (R911343901).


Comparison of Technical Data for Three Major Models

Project VDP 16.3 VDP 40.3 VDP 60.3

Display screen 305 mm TFT (12 "), 800 × 600 pixels, 16.7 million colors 381 mm TFT (15"), 1024 × 768 pixels, 16.7 million colors 483 mm TFT (19 "), 1280 × 1024 pixels, 16.7 million colors

Operation mode: Touch screen (DB)/button (BK) Touch screen (DE), button (BI), dual operation (DF), touch+switch element (DI) Touch screen

Current consumption 0.85 A 1.05 A 1.7 A

Power consumption 20 W 25 W 40 W

Weight 4.0 kg 5.8 kg 7.3 kg

Panel width x height 350 x 290 mm (AK customized version 360 x 300 mm) 407 x 370 mm (AL customized version 417 x 380 mm) 483 x 400 mm

Unified specifications for all models: front panel IP65 (DIN EN 60529), NEMA Type 1 (front), back panel IP20; Power supply DC 24V, requires the use of a 24V power supply unit that complies with DIN EN 60742 (classification VDE 0551), recommended VAP01.1H-W23-024-010-NN (part number R911171065); The maximum current for a single USB port is 500 mA, and the total current for all USB ports is 1 A. The front panel USB ports (if any) come with an IP65 protective cover. Customized version (VDP 16.3AK designed for Bosch in the food industry) VDP 40.3AL、 The FE/FI design of 60.3 has slight differences in appearance and interface configuration, such as the AK and AL versions having no USB connection.

Electrical installation dimensions: VDP 16.3 opening 318 × 275 mm, installation depth 41 mm; VDP 40.3 opening 375 × 338 mm; VDP 60.3 opening 453 × 370 mm. All models require 8 mounting bolt holes with a diameter of 5 mm.


Certification and Environmental Conditions

The equipment complies with the EU EMC Directive 2004/108/EC and adopts DIN EN 61000-6-4 (Industrial Environment Emission, September 2007 edition) and DIN EN 61000-6-2 (Industrial Environment Immunity, March 2006 edition) harmonic standards; Certified by UL508 (Industrial Control Equipment) and CSA C22.2 No. 142-M1987, UL file number E210730- however, certification is only valid for delivery in its original condition, and any modifications must be revalidated for CE and UL/CSA compliance.

Environmental conditions: Operating temperature+5 to+45 ℃, with a maximum temperature change rate of 3 K/minute; Transportation: -20 to+60 ℃ (climate level 2K2), storage: 1K2; relative humidity: 5-85% (operation), absolute humidity: 1-29 g/m ³, condensation is prohibited; Operate at an altitude of 3000 meters (EN 61131-2). Mechanical strength: Operating vibration of 10-150 Hz, acceleration of 1 g at 57-150 Hz (EN 60068-2-6); Transportation/storage impact of 15 g, 11 ms (EN 60068-2-27); Pollution level 2, overvoltage category 2.


Key points for selecting accessories and cables

Y distributor VAC 01 (VAC01.1S-YD1-NNN, part number R911171187): Used to connect two operation display terminals with the same resolution and version to the same control cabinet PC. It can cascade up to four devices - when expanding the display, the resolution of the two devices must be consistent.

CDI connection cable (RKB0008 series, part number R911171484 onwards): available in twelve lengths ranging from 0.5m to 50m. Key constraint: Two cables (data line XSER+image line XVID) are always required between VxB and VDP. The cables listed must be used, as non specified CDI cables may cause malfunctions.

USB connection cable (RKB0019 series): 0.5/1/3/5 m. When using UPS in strong noise environments, a high anti-interference USB cable (RKB0050 series, part number R911172944/45) must be used between the control cabinet PC and the VAU 01.1 U with communication interface to avoid potential malfunctions.

UPS uninterruptible power supply (VAU01.1U-024-024-240-NN, part number R911171024, DC 24 V/240 W with USB interface). Please refer to the VAP 01 manual for the selection of power supply units. The touch screen belongs to the category of vulnerable parts and can only be operated with fingers or a dedicated stylus (part number 1070923266). Improper use of objects can damage the touch screen or front panel.


Detailed explanation of interfaces and DIP switches

List of connection panel interfaces: X1S1 (3-pin MC1.5/3-G-3 STHT socket, DC 24V power supply, equipped with FK-MCP 1.5/3-ST-3.5 docking terminals), XUSB1/2 and XUSB3/4 (USB-A female socket × 4), XSER (RJ45 female socket, CDI data interface, purple identification), XVID (RJ45 female socket, CDI image interface, black identification), XUSBIN (USB-B female socket, USB2.0 connected to control cabinet PC, maximum wire length of 5 m, requiring high-speed USB2.0 cable in Chapter 5), functional grounding FE (M5 thread, circular wire nose). Insufficient shielding can lead to malfunctions - only shielded cables and metal/conductive connector shields with large-area shielding support can be used.

X1S1 pin definition: 1 pin+24 V, 2 pins 0 V (GND), 3 pins N.C. Only copper wires can be used for wiring terminals.

S1 DIP switch is only valid for S1/2 (S1/1 has no function): OFF=control cabinet PC cable length ≤ 30 m; ON=cable length>30 m.

The linkage relationship between USB speed and XSER cable length (core configuration logic):

XSER cable length S1/2 status USB speed note

≤ 5 m OFF 12 Mb/s or 480 Mb/s (USB 2.0) 480 Mb/s requires an additional USB cable between the control cabinet PC and XUSBIN

5-30 m OFF 12 Mb/s Ensure that the connected device does not include a USB hub

>30 m ON 12 Mb/s does not support USB hub

The interference free USB 2.0 connection is only feasible for wires with a length of less than 5 meters. Warning: When the total current of all USB connectors exceeds 1 A, the VDP power supply will automatically shut off. A single port of 500 mA and a total of 1 A are the hard upper limits. Only devices that comply with USB specifications can be connected.

Installation and disassembly process

Installation prerequisite: Leave 50mm of space around the equipment to ensure heat dissipation and wiring; LED display cannot be covered; All cables are looped and secured with stress relief components; Try to stay as far away from noise sources as possible; Can only be installed vertically, with a maximum deviation of ± 45 ° from the vertical position; CDI cables must not be laid parallel to motor cables or other noise sources, otherwise the CDI connection may be disturbed.

IP65 protection retention conditions: The chassis for installing the monitor must be free of burrs, have sufficient mechanical strength and flatness - these conditions directly affect the actual protection level, and if necessary, measures such as reinforcing the installation frame must be taken.

Four step installation: ① Make 8 openings with a diameter of 5mm according to the installation size diagram; ② Remove the paper lining from the sealing strip on the back of the front panel; ③ Insert the monitor from the front to the back through the opening, and insert the M4 mounting bolt into the drilled hole; ④ Tighten the nut on the back to secure it.

Tightening torque (excessive torque is strictly prohibited from damaging the mechanism): M2.5=0.4 Nm, M3=0.7 Nm, M4=1.4 Nm, M5=2.8 Nm. After maintenance and disassembly, tighten according to this table.

Dismantling: Disconnect the display terminal → Remove all connected cables → Remove all installation nuts → Carefully push the monitor out of the installation hole from the back to the front.


Key rules for electrical wiring and functional grounding

230 V/400 V wiring level (overvoltage category I/II/III zones): The main line entering the control cabinet (16 mm ² green and yellow line connected to the cabinet body, 14 mm ² connected to the equipment, 6 mm ² connected to the functional ground of all casing components) passes through a fuse (recommended motor protection switch) → Transformer according to EN 60742 → Overvoltage category II zone 230 V power supply service terminal → VAP01 power supply unit outputs DC 24 V to X1S1, with a maximum length of 24 V output line of 4 m. Danger warning: Power supply units designed for overvoltage category III can be connected to category II or III power grids; But power units designed as Class II can only connect to Class II power grids - misconnecting a protective extra low voltage (+24 V) power source to a mismatched grid can endanger life due to electric shock.

The lack of functional grounding (FE) leads to damage to electronic components - this is the most critical rule in the wiring of this device: if the functional grounding between VDP and control cabinet PC is not connected, once the voltage supply is interrupted and only one device is powered on again, the potential difference between VDP and PC will burn out the electronic components. The best solution is to directly connect the VDP and the control cabinet PC to the functional ground; If the functional ground is connected to the neutral point, the control cabinet PC must also be connected to that neutral point.

CDI connection three-step: ① Grounding the connection function; ② Display purple XSER → XSER of control cabinet PC; ③ Monitor black XVID → Control cabinet PC XVID.

CDI cable bending radius (diameter 7.4 mm): one-time installation bending 4 x wire diameter; Frequently move the minimum wire diameter of 8 times; Regularly move the optimal 12.5 x wire diameter. Avoid applying tensile, compressive, torsional, and lateral mechanical stress to the RJ45 female connector - mechanical stress can cause operational interruption; Cables should be clearly marked with wire markers or clamps to prevent accidental replacement and potential malfunctions.

CDI maximum line length is distinguished by resolution: 1280 × 1024 pixels (VDP 60.3 only) up to 60 m; 1024 × 768 pixels (VDP 40.3 and 60.3) up to 70 m; 800 × 600 pixels (all VDP xx. 3) up to 80 m. Longer line lengths can be achieved through Y allocator.

Resolution and hot swappable constraints: The display resolution can only be detected after the control cabinet PC restarts - when inserting or unplugging VDP during VDP operation or connecting VDP during PC startup, only VDP with the same resolution as the current PC can be reconnected to ensure that the screen output of connected and disconnected devices can automatically switch without keyboard operation.


UPS power supply scheme and overall connection

The core value of the UPS solution is that if the display terminal is directly connected to a 24V power supply without going through UPS, the display will immediately turn black when the power is cut off, and users will not be able to perform any operations during the shutdown process of the control cabinet PC; When the monitor and control cabinet PC are connected to the external UPS's "24 V Out", users can still operate the display terminal during the power-off process.

Recommended wiring scheme (VAU 01.1, X1S1 in/X1S2 out): 24V power supply unit → UPS 24V IN → UPS 24V OUT → Phoenix UK6-FSI/6 automatic fuse connection terminals (control cabinet PC branch TCP 10A, display terminal branch TCP 4A) → to control cabinet PC X10 and display terminal X1S1 respectively; The 16A incoming line, 6mm ² (blue) 0V line, and PE row 10/6/6/10mm ² green and yellow lines are respectively connected to the display terminal FE, control cabinet PC FE, UPS FE, and power supply unit. The downgrade plan of only connecting the PC to UPS and not connecting the monitor to UPS is also supported. The USB cable is connected from the UPS to the control cabinet PC for communication, and the control cabinet PC is connected to the display via USB (XUSBIN, maximum 5m).

The debugging process is extremely simple: the product can be used directly without any configuration.


Button system and LED diagnosis

The membrane keyboard is designed to be language independent and comes pre installed with English keyboard drivers for use in other language user interfaces. The factory delivery settings cannot be changed; When connecting an external USB keyboard (such as VAK), the corresponding keyboard driver needs to be selected.

Key partition: The left L1-L8 and right R1-R8 are eight machine function keys (M-keys); The allocation of F2-F9 function keys and OP2-OP9 operation keys is determined by the application software. The OP key transmits combination key codes to the operating system (OP2-OP9=<CTRL>+<SHIFT>+<ALT>+<F2... F9>, Prog=<Ctrl+Q>, INFO=<Ctrl+I>). M-keys have three reading paths: ① as a USB keyboard signal transmitted to the PC (when UpperClassFilter is activated, L1-L8 maps<Ctrl>+<Alt>+<LShift>+<1... 8>, R1-R8 maps<Ctrl>+<Alt>+<RShift>+<1... 8>); Map F13-F20 and F21-F24 with four OEM special characters when not activated - if using a USB dedicated keyboard, insert the corresponding Ctrl combination code into the data stream upon detecting the M-key code); ② The CDI interface serial connection bit encoding is transmitted to the control cabinet PC, which can be output from the station card (including GSD files) via Profibus DP, and a wiring terminal block is provided to transfer to the expansion card; The transmission protocol is guaranteed by hardware, and when the connection is disrupted or interrupted, the M-key bit that arrives is disabled after 10 ms; ③ Output by byte via Profibus DP (Byte 0=Bit7-0 corresponds to R8 – R1, Byte 1=Bit7-0 corresponds to L8 – L1), key=1, not pressed=0.

Four LED status diagnosis (top of panel):

Disposal of LED status meaning

Power green is always on and running normally (this VDP is the active end under the Y distributor) -

Green flashing and no serial connection to the control cabinet PC → Check the cable; Inactive VDP under Y allocator → No action required

Turn off the DC 24V power supply and check the power supply voltage

HDD Yellow Always Bright Hard Disk Access -

Yellow flashing SMART analysis found error in replacing hard drive

Temp red flashing control cabinet PC fan does not rotate or the speed is too low. Check the control cabinet PC fan

Red constant brightness temperature>50 ℃ reduces the surrounding air temperature!

UPS red constant light control cabinet PC is running in UPS mode, power supply is unavailable, restore power supply, execute controlled restart of control cabinet PC

Note: Not all LEDs are activated with the connected control cabinet PC, so not all warnings and information will be displayed - supplementary information must be consulted in the corresponding documentation of the control cabinet PC.


Troubleshooting and Maintenance

Typical fault handling table:

Troubleshooting measures

No image display connection power supply voltage and check X1S1; Correctly connect the CDI cable and check XVID and XSER; Set the screen output to "VDP" in the graphics card driver; Power on VDP before or simultaneously with the control cabinet PC

Display resolution error: Set the correct resolution in the graphics card driver; Restart the control cabinet PC

The USB flash drive is not working (other USB devices are functioning properly). Set the DIP switch on the VDP to the<30 m level

All USB devices and touch screens are not working. Set DIP switches correctly according to cable length

Touch screen function unavailable, recalibrate touch screen

Maintenance points: During maintenance, it is necessary to ensure that the IP protection level is not lost. Backlight is a vulnerable component: it has a service life of about 50000 hours at an ambient temperature of 25 ℃. After exceeding the service life, the brightness will only be reduced to 50% of the original value - the backlight gradually darkens, causing the readability of the display to gradually deteriorate. If you need to replace the display screen, please contact Bosch Rexroth service. To extend the lifespan of LCD backlight, the device has a built-in backlight off function: the panel PC will "dim" after a period of inactivity, and the time interval is set in the "Power Options" of the Windows control panel (Never/1 minute to 5 hours optional).

Cleaning taboos: The surface of the film and the sealing strip of the display screen will be dissolved by solvents - do not use any solvents (such as diluents), and do not use high-pressure cleaning equipment.

Annual routine maintenance: At least once a year, check the fastening condition and possible damage of all component plugs and terminal connections; Confirm that the cable is not broken or crushed; Replace damaged parts immediately.


Model code and ordering, disposal

The model code consists of nine digits and two optional digits: VDP+wire number (16/40/60)+design generation (3)+front panel and display (16.3: BK=12 inches with 16 MTX machine keys, DB=12 inch touch screen, AK=Bosch design for the food industry; 40.3: BI=15 inch MTX key, DE=15 inch touch, DF=touch+MTX key, DG=17 inch touch, DI=touch+switch element, AL=15 inch Bosch touch; 60.3: FE=19 inch touch strip with front USB, FI=19 inch MTX key)+additional options (N none)+control panel interface (D1=CDI)+interface (NN none)+other designs (MX=MTX design, CG=built-in in system chassis, NN none).

Disposal and Recycling: Products can be shipped back to Bosch Rexroth for free disposal (freight collect), provided that there are no impurities such as oil stains, foreign objects, or foreign components; Packaging materials (cardboard, plastic, wood, EPS) can be easily recycled. For ecological reasons, do not return empty packaging.

Service Support: Lohr Capability Center Service Hotline+49 9352 40 5060 (Fax 40 4941), Germany, service.svc@boschrexroth.de Global network 24/7 response; Please contact the local service office outside of Germany. Preparation before seeking help: detailed description of the fault and its cause, product nameplate name (especially model code and serial number), contact information (phone, fax, email).

  • Rexroth VCP25.1BVN-003PB-NN-PW Operator Panel
  • Rexroth RKL4305/002.5 Power Cable L=250cm
  • Rexroth MSM031C-0300-NN-M5-MH1 R911344216 Servomotor
  • Rexroth CSH01.1C-SE-EN2 R911335435 Control Unit
  • Rexroth FEM-E-S 25x10RX3-4 R151224013 Ball Screw
  • Rexroth FCS01.1E-W0005-A-04-NNBV Frequency Drive
  • Rexroth 0510-425-009 Hydraulic Gear Pump
  • Bosch Rexroth IndraControl XM42 Controller R911396964
  • Rexroth VT5035-17 R900579497 Valve Amplifier
  • Rexroth FCS01-1EW0015-A-04 R91131106 Frequency Drive
  • Rexroth MSK050B-0600-NN-M1-UG1-NNN Motor
  • Bosch Indramat TBM1.2-40-W1-115 Bleeder
  • Rexroth HCS01.1E-W0028 Compact Converter
  • Rexroth Indramat MAC071B-0-PS-2-C/095-A-0 Motor
  • Rexroth HCS02.1E-W0012-A-03-NNNN Drive Set
  • Rexroth R-IL S3 BK DI8 DO4-PAC Coupler
  • Rexroth HCS01.1E-W0028-A-03-E-S3-EC-NNN Drive
  • Rexroth MSK061C-0600-NN-S1-UG0-NNNN Motor
  • Bosch Rexroth MSM041B-0300-NN-M0-CH0 Motor
  • Rexroth IKG0071-05.0m Servo Motor Cable
  • Rexroth R-IL S3 BK DI8 DO4-PAC Bus Coupler
  • Bosch Rexroth SB301 Tightening Unit 0608701017
  • Rexroth E-003-S-S Tool Cable 0608740220
  • Rexroth MSM020B-0300-NN-M0-CG0 Servo Motor
  • Rexroth IndraControl VEP30.3 Panel PC
  • Rexroth DBETE-62/315G24K31A1V Valve R901029969
  • Rexroth CSH01.3C-ET-ENS-NNN Control Section
  • Rexroth VT3013-37 Amplifier Control Card
  • Rexroth 1-2 TH6 L 162-10/N 05 Joystick
  • Rexroth ESV025 Handheld Nutrunner 0608841037
  • Rexroth RK2 S30 Amplifier Card VT 4224 U 261
  • Rexroth CDB01.1C-SE-ENS R911308279 Control Unit
  • Rexroth VFC3610-0K40-3P4-MNA-7P Inverter 0.4kW
  • Bosch Indramat HCS02.1E-W0028-A-03-NNNN Servo Module
  • Rexroth DKC01.3-040-7-FW EcoDrive R911279426
  • Rexroth HMV02.1R-W0015-A-07-NNN Utility Unit 15kW
  • Rexroth 0 608 830 193 ZSE220 Communication Module
  • Rexroth VT5003 S41 R5 Proportional Amplifier Card
  • Rexroth KSM02.1B-041c-42N-M1-HP0-ET-L3-D7-NN-FW Motor Drive
  • Mannesmann Rexroth VT5005 S16 R1 Valve Amplifier Card
  • Rexroth CFL01.1-R3 Sercos III Interface Module
  • Rexroth CKK-110-NN-1 Linear Axis with MSK040C
  • Bosch Rexroth 047018-104401 Controller Card
  • Rexroth MDSD1K-2X/4 Solenoid Driver Module
  • Rexroth DKC02.3-012-3-MGP-01VRS Servo Drive
  • Rexroth HCS01.1E-W0006 Compact Servo Drive
  • Rexroth NAM1.2-08 Line Former R911246505
  • Rexroth VPB40 Industrial PC Control Cabinet
  • Rexroth FWA-ECODR3-SGP-03-MS Firmware Module
  • Rexroth HEDE10-31 Pressure Switch R901425475
  • Rexroth HM 17-11/315-C/V0/0 Pressure Sensor
  • Rexroth VFC 3610-2K20-3P4-MNA-7P Inverter 2.2kW
  • Rexroth MSK040C-0600-NN-M1-UG1-NNNN Right Angle Geared Motor
  • Rexroth DKC02.3-012-3-MGP-01VRS EcoDrive Cs
  • Bosch Rexroth MSM031C-0300-NN-M0-CH0 Servo Motor
  • Rexroth HCS02.1E-W0012-A-03-NNNN Power Section
  • Rexroth DBDS 20 P18/400V Pressure Relief Valve
  • Rexroth 3460565500 Pneumatic EP Converter Regulator
  • Rexroth VT-SWA-1-12/DFEE Angle Sensor R900913641
  • Rexroth 0-608-830-250 Interface Module SM24V
  • Rexroth MHD071B-035-NP0-UN8 Servo Motor 12Nm 1000rpm
  • Rexroth MKD025B-144-KG0-KN R911263737 Servo Motor
  • Rexroth KCU02.2N-ET-ET*-025-NN-N-NN-NW Control Unit
  • Rexroth MV-VPB40*3-RB001VPB R911337529 Valve Terminal
  • Bosch Rexroth AS 2/R-2200 Drive Module 3842998041
  • Rexroth HMS01.1N-W0036 Power Section
  • Rexroth CKK-145-NN1 Compact Linear Module
  • Rexroth MS2N04-C0BTN-BSDK0-NNNNN-NN Geared Servo Motor
  • Rexroth HCS02.1E-W0028-A-03-NNNN Power Section
  • Rexroth MS2N04-D0BQN-CMSG0-NNNNN-NN Servo Motor
  • Rexroth MSM031C-0300-NN-M0-CH0 Servo Motor
  • Rexroth MKD041B-144-KP1-KN Servo Motor R911262307
  • Rexroth ESA075G Handheld Nutrunner 0608841033
  • Rexroth MSK070D-0450-NN-M1-UP1-NSNN Motor
  • Rexroth CKK-145-NNG1 Linear Kit with HCS02 Drive
  • Rexroth MSK060C-0300-NN-M1-UG0-NNNN Servo Motor
  • Rexroth MKD090B-047-KP1-KS Servo Motor
  • Rexroth MLS140S-3A-0450-NNN Linear Motor
  • Rexroth VPB40.3 Industrial PC R911338689 CB1
  • Rexroth HCS02.1E-W0012 Servo Drive R911313871
  • Rexroth R151349014 R151145672 Ball Screw Assembly
  • Bosch Rexroth CKK-110-NN-1 Compact Module
  • Rexroth MSK060B-0300-NN-M1-UG1-NNNN Servo Motor
  • Rexroth Indramat TBM 1.2-40-W1-024 Servo Bleeder
  • Rexroth MSK040B-0600-NN-M1-UG1-NNNN Servo Motor
  • Rexroth MLS200S-3A-0450-NNN R911299213 Linear Motor
  • Rexroth SB356 Tool Tightening Controller Rack
  • Rexroth MSK050C-0300-NN-M1-UG0-NNNN Servo Motor
  • Rexroth Indramat DKC11.3-040-7-FW Eco Drive
  • Rexroth VT2000 Proportional Amplifier
  • Rexroth VT1118-10 Analog Module
  • Rexroth MSK060C-0600-NN-M1-UP1-NSNN Motor
  • Rexroth MSK060C-0300-NN-S1-UG0-NNNN Motor
  • Rexroth R911173937 IndraControl XM AI1
  • Rexroth R412018225 AES-D-BC-ECAT Module
  • Rexroth CDB02.1B R911338542 Controller Card
  • Rexroth VT-HNC100-2-30/P-I-00/000 Module
  • Bosch Rexroth CSB02.1B R911372549 Control
  • Bosch Rexroth R185321310 Runner Block
  • Rexroth VPB40.3 Industrial PC R911338689
  • Rexroth HNK01.1A-A075-E0106-A-500 Drive Controller
  • Rexroth CSH02.1B-CC-EC-ET-S4-NN-NN-FW Controller
  • Rexroth CSB01.1C-PB-ENS-NNN Control Unit
  • Rexroth MKD041B-144-KP0-KN Permanent Magnet Motor
  • Rexroth SE-B2.020.030-14.000 Servo Motor
  • Rexroth MSK060C-0600-NN-M1-UG0-NNNN Servo Motor
  • Rexroth HCS01.1E-W0018-A-03-B Drive Controller
  • Rexroth 3 842 547 996 IE3 Geared Motor
  • Rexroth CSH01.1C-NN-ENS R911309709 Control Section
  • Rexroth R151349013 Ball Screw Nut
  • Mannesmann Rexroth VT3006-36 Analog Amplifier Card
  • Bosch Rexroth R900086160 PGF1 Gear Pump
  • Bosch Rexroth R911173263 VDP15.3 Touch Display
  • Bosch Rexroth PPC-R22.1 RJ522 Industrial Controller
  • Bosch Rexroth MSK060C-0300-NN-S1-UG0-NNNN Servo Motor
  • Bosch Rexroth R911325068 NYS04.1 Controller
  • Bosch Rexroth R911335439 CSH01.1C Control Unit
  • Bosch Rexroth R917010287 BODAS RC10 Controller
  • Bosch Rexroth R911329791 CSH01.1C Drive Controller
  • Bosch Rexroth R182432310 Runner Block Guide
  • Bosch Rexroth VT-VSPA2-1-11 Amplifier Card R900021909
  • Bosch Rexroth MKD090B-047-KG1-KN Servo Motor
  • Bosch Rexroth LTU350 Servo Amplifier 0608750108
  • Bosch Rexroth 5610102050 Pneumatic Vacuum Regulator
  • Bosch Rexroth VT5041-23/3-OV PLC Control Board
  • Bosch Rexroth VT3015 S10/E Servo Amplifier Board
  • Bosch Rexroth MSK070D-0300-NN-M2-UG1 Servo Motor
  • Bosch Rexroth 3DREP6C-21 Valve R900955887