Product positioning and technical characteristics
The MSK series synchronous servo motor is a permanent magnet excitation three-phase synchronous motor launched by Bosch Rexroth for the field of machine tools and automation, designed specifically for operation with Rexroth frequency converters or inverters. This series covers fifteen machine base specifications including MSK030, -040, -043, -050, -060, -061, -070, -071, -075, -076, -100, -101, -103, -131, and -133. It has been certified by UL 1004 Fifth Edition and Canadian C22.2 No. 100-04 standard (UL file number E 335445), and meets the requirements of the EU Low Voltage Directive 2014/35/EU and EN 60034-1/-5, with CE and cURus marks; Only products with SI identification on the motor nameplate can be used for functional safety systems that integrate safety technology.
Core parameters: Operating environment temperature from 0 to 40 ℃, machine base form B5/B35 (IM B5/V1/V3/B3 installation type), protection level IP65 (EN 60034-5), vibration severity level A, flange according to DIN 42948, cylindrical shaft end (DIN 748 Part 3, optional keyway, with DIN 332 Part 2 center hole), installation altitude from 0 to 1000 meters, sound pressure level<75 dB (A), insulation level 155 (TCL 155/F), full key balance, power supply and encoder use two electrical connection methods: flange socket or junction box. Optional electric release holding brake (24V DC ± 10%).
The encoder system is divided into two lines: S1 (optical single loop Hiperface, 128 signal cycles), S2 (optical single loop EnDat 2.12048 signal cycles), S3 (capacitive single loop Hiperface, 16 signal cycles), M1 (optical multi loop Hiperface), M2 (optical multi loop EnDat 2.1), M3 (capacitive multi loop Hiperface, 16 signal cycles). The bearing adopts a permanently lubricated deep groove ball bearing, with the fixed bearing located on the B side. According to the project planning specifications, the shaft and bearing loads are calculated, and the nominal bearing life L10h is 30000 hours.
Cooling scheme and installation spacing requirements
MSK provides three cooling paths, which must be clearly distinguished when designing and selecting:
Natural convection (NN): The nominal data is achieved at ambient temperatures up to 40 ℃, and the installation location must ensure sufficient thermal radiation. The side surface must maintain a minimum distance of 100 mm from adjacent components to ensure unobstructed vertical convection. Dust accumulation on the surface of the motor can reduce its heat dissipation capacity and cause thermal overload.
Surface ventilation: achieved by external radial (LEM-RB) or axial (LEM-AB) fan units. Fan pollution can reduce air volume and cause motor thermal overload. Only clean ambient air must be used, and heated air must not be sucked back. The following working conditions explicitly prohibit the use of fans: conveying air containing abrasive particles, air containing highly corrosive media (such as salt spray), high dust air (such as sawdust extraction), conveying combustible gases/particles, and using fans as safety related components or performing safety related functions. The installation of the fan must reserve a minimum distance of 80 mm from the intake area outside the fan during the design phase.
Liquid cooling (FN): It is only allowed to operate in a closed cooling circuit with a heat exchanger, and the flow direction of the coolant can be freely selected. Preservatives need to be added to the cooling circuit. Cooling connection thread specifications and torque: MSK071/075 is ISO 228 G1/8 (screw in depth 8 mm, torque 14-15 Nm), MSK101 is G1/8 (9 mm, 14-15 Nm), MSK133 is G1/4 (14 mm, 18-20 Nm). **Warning: Exceeding the allowable torque or screwing in depth will irreversibly damage the motor cooling port threads. **Recommend using joints with O-ring axial seals; Sealing with hemp thread, raw material tape, or tapered thread is not recognized as it may apply excessive stress to the motor threads. The maximum inlet pressure is 6 bar (3 bar for FD 10W01 motor before January 1, 2010). The sealing of the cooling connection is the responsibility of the machine manufacturer, and it must be checked and confirmed after installation and included in the maintenance plan for regular verification.
In terms of protection level: the motor housing, output shaft, and correctly connected connectors are IP65 standard version; Cooperate with sealed air accessories to achieve IP67 rating; The fan motor and docking connector are IP65, and the fan grille is IP24. The sealed air solution requires a compressed air interface provided on the system side, with a working pressure of 0.1 ± 0.05 bar, relative humidity of 20-30%, dust-free and oil-free, and equipped with SUP-M01-MSK (RGS1000 encoder connection) or SUP-M02-MSK (RLS160 power connection) accessory kits. The end cap screw torque RGS1000 is 1.3 Nm, RLS1600 is 3.1 Nm, and LOCTITE 243 thread locking adhesive is used.
Interpretation of Model Code and Nameplate
The MSK model code consists of the machine base size, machine base length, and winding (xxx0 standard; Xxx2 includes weak magnetic operation parameters, such as 0302), cooling mode (NN natural convection, optional fan for specifications 060 and above; FN liquid cooling), encoder (Mx/Sx+optical x1/x2 or capacitor x3), electrical connection (U rotatable 240 ° connector L/A/B/E/F)、 Shaft (G axis with shaft seal, P keyway shaft with shaft seal, K cone shaft with shaft seal), holding brake (0 without, 1/2/3 with) and shell design (NNNN standard); XSxx is designed for Ex explosion-proof according to EN 60079; Nxxxx/Rxxx corresponds to DIN 42955-N/R tolerances; Xx01 short axis; Xx02 JIS taper shaft; Xx35 B35 installation; XxAx enhances vibration resistance; XxBx fixed bearing A side; XxPx sealed air connection; XxVx reinforced bearings; XxxK 17 pole encoder connection) is composed of equal bit segments.
The nameplate records 26 items of information, including model number, serial number, production date, revision status, CE/UL compliance, weight, torque constant (20 ℃), voltage constant, maximum speed, static current and static torque (surface or liquid cooled), 60K static continuous current/torque, braking data, and protection level - both service repair and spare parts queries rely on the model code and serial number on the nameplate.
Transportation, storage, and disposal before commissioning
Transportation must maintain the original packaging and meet the 2K2, 2B1, 2C2, 2S2, 2M1 grades of DIN EN 60721-3-2: temperature -20 to+80 ℃, maximum relative humidity of 75% (at+30 ℃), and no salt spray. **Before transporting liquid cooled motors, the coolant must be drained to prevent freezing damage. **Only lifting devices that match the weight of the motor (slings or eyebolts, confirmed to be tightened before use) can be used for lifting. It is strictly prohibited to lift the shaft end or fan cover, and it is strictly prohibited to stand under the lifting load. Safety shoes and other protective equipment must be worn during transportation. The installed components (KTY84, encoder) contain electrostatic sensitive devices and must comply with ESD protection measures. Remove the transportation locking components and store them properly before operation.
Storage level 1K2, 1B1, 1C1, 1S1, 1M2: Temperature -20 to+60 ℃, relative humidity 5-95%, absolute humidity 1-29 g/m ³, no condensation, no freezing, no salt spray, only stored in rainproof and dry rooms. Pre operation disposal checklist corresponding to storage time:
Any duration: visual inspection of all components for no damage; Re run in to maintain the brake surface;
Over 12 months: Check that the electrical contacts are not corroded; Run at 800-1000 rpm for 1 hour without load to break in the bearing; Measure insulation resistance (dry the winding when below 1 k Ω/rated voltage volts);
Over 60 months: Replace bearings and encoders.
Cables and connectors: Conduct visual inspection at any time; Check for contact corrosion after more than 12 months; After more than 60 months of inspection, if any abnormalities such as indentation, twisting, discoloration, etc. are found on the cable sheath, it is prohibited to use it.

Mechanical installation specifications
Flange installation: When the motor housing output shaft seal ring comes into contact with liquid for a long time, it may seep into the motor and cause damage - it is necessary to ensure that there is no liquid present at the output shaft, and it is forbidden to install non sealed open gearboxes. When connecting directly, the support surface must be flat and oriented accurately to avoid crushing the motor side positioning flange and damaging the equipment side mating surface. All installation holes should be used. Tightening torque (friction coefficient μ K=0.12): M4 × 20 (3 Nm) for a hole diameter of 4.5 mm, M6 × 20 (10.1 Nm) for a hole diameter of 6.6 mm, M8 × 20 (24.6 Nm, with washer) for a hole diameter of 9 mm, M10 × 30 (48 Nm) for a hole diameter of 11 mm, M12 × 40 (84 Nm) for a hole diameter of 14 mm, M16 × 35 (206 Nm) for a hole diameter of 18 mm, with washer specifications DIN EN ISO 28738.
Foot installation: The installation holes and gaps shall be executed according to the general tolerance of DIN ISO 2768-1 (m level). The motor axis must be aligned with the connecting shaft axis before tightening (MSK133 recommends M10 screws, 48 Nm, 28738 washers). The essential difference between foot installation and flange installation is that radial force is only allowed to act in the direction perpendicular to the installation surface (± 15 °), and force transmission in other directions is prohibited; The force transmitted from the gear shaft to the motor foot is not allowed to exist - the force acting through the gear shaft must be borne by the gear, otherwise it will cause short-term damage to the motor. If necessary, flange installation should be used instead.
Assembly and disassembly of transmission components: Belt pulleys, couplings, etc. can only be assembled and disassembled with appropriate tools (heated if necessary) to prevent unacceptable belt tension. The allowable radial and axial forces are subject to the project planning manual; The balance state of the transmission components must meet the requirements of motor full key balance. It is strictly prohibited to strike the shaft end or exceed the allowable axial/radial force of the motor - use the central hole to install the transmission parts, and protect the shaft end with a gasket during disassembly.
Electrical Connection Specification
Safety prerequisite: Electrical work can only be carried out by certified electricians and VDE electrical tools must be used. The first five steps of the homework process are: isolation (including auxiliary circuits) → anti reclosing → confirmation of no voltage → grounding and short circuiting → shielding of adjacent live parts. After completion, the process is lifted in reverse order. Permanent magnet motors will generate a voltage of>60 V at the motor terminals when the rotor rotates - all operations can only be carried out when the motor is stationary, and it is strictly prohibited to plug or unplug connectors with power on.
Connector scheme (RLS 110/1200/1300 power supply, RGS 1000/1010 encoder): prioritize the use of Rexroth finished cables; Connect the wires according to the circuit diagram in the project planning manual; The vibration O-ring is not visible after the screw connector is fully tightened; The connection should only be made in a power-off, dry, and clean state; Prevent the connector from being subjected to external forces. When adjusting the orientation of the rotatable connector, the maximum torque for RGS1000/RGS10/RLS1 100 is 12 Nm, and for RLS1 200 it is 18 Nm. The orientation adjustment should not exceed 10 times.
Junction box scheme (RZK3100/RKL1200/RKL1300): torque of 4 screws on the cover plate is 5.9-7.1 Nm; maximum power wiring is 16 mm ² (U/V/W M6 terminal 2.5 Nm, PE M8 terminal 3.8 Nm, temperature/brake spring terminal 0.2-2.5 mm ²); Adaptation board screw 9 Nm ± 10%; Apply Loctite 243 to the cover plate screws and tighten them with 6.5 Nm ± 10%. Before installing the cover, check the condition of the adhesive sealing strip. Double cable wiring is used in situations where a single cable has limited bending radius or cross-section. F1 fuses are selected based on the current carrying capacity of the cable cross-section and installed as close as possible to the controller output. The shielding layer of the motor power cable must be extensively connected to the control cabinet on the motor side of the fuse. Unused cable entrances must be sealed to ensure dust and water resistance.
Fan wiring: Connect single-phase plug RLS0780 (115/230 V) to three-phase RLS0782 (400 V) according to the nameplate voltage; The "T" type fan has built-in thermal protection and does not require an external motor protection circuit, while the "N" type requires external configuration.
Operation monitoring and typical fault troubleshooting
The prerequisites for operation include: completing the disposal according to the storage time (running in bearings, heavy grinding and holding brakes, etc.), correctly connecting all connectors to prevent loosening, applying a holding brake voltage of 24 V ± 10% and functioning properly, ensuring that all components of the motor and drive chain are intact, and preventing key components from being ejected. The brake check and voltage adjustment should be implemented item by item.
Continuous inspection items during operation: abnormal noise, increased vibration, cleanliness of motors and fans, sealing of cooling connections, controller monitoring and diagnostic/error messages. Once deviating from the normal operating state, the machine should be stopped immediately for troubleshooting.
Typical Fault Comparison Table:
Possible causes and measures for troubleshooting
Motor not running, controller enable signal missing/controller malfunction/power supply missing/holding brake not released activation enable signal; Check according to the controller documentation; Check the control voltage; Check the activation of the holding brake
Poor balance of vibration coupling or accessories/insufficient alignment of shaft end accessories (coupling, gearbox)/loose installation screws for rebalancing; Re centering; Lock the threaded connection according to specifications
Running noise, foreign objects inside the motor/damaged bearings, shutdown → return to the factory for repair
Motor temperature is too high/temperature monitoring activation exceeds rated data operation/heat dissipation is obstructed, load reduction is carried out and selection is checked; Clean the motor; Fan cleaning and fence inspection function; Liquid cooling inspection cooling circuit
Temperature display error or failure. The temperature sensor is not connected or the sensor is damaged and connected to the sensor; Shutdown and return to the factory or connect backup sensors
Maintenance, replacement, and disassembly
Cleaning and maintenance: Excessive dirt, chips, and dust can affect the function of the motor, and in extreme cases, the motor may be scrapped - the cooling fins should be cleaned at least once a year to ensure sufficient heat dissipation area. Damaged connecting cables must be replaced immediately and the equipment must be stopped. Temporary repair of connecting wires is strictly prohibited; Regularly inspect for defects in the drag chain and ensure the integrity and fastening of the protective conductor connections.
Wear life of vulnerable parts: The life of seals and bearings varies with operating mode, speed, vibration impact, and frequent commutation. Suggest replacing bearings after 30000 operating hours (the short-term replacement interval may be earlier depending on the results of the operation inspection); It is recommended to conduct regular visual inspections on the shaft seal ring, and replace it if necessary after 5000 hours of operation. The above repair suggestions should be handled by Bosch Rexroth service.
The seven step process for motor replacement: ① If necessary, record the previous absolute value; ② Turn on the main switch; ③ Ensure that the main switch cannot be closed again; ④ Disconnect the plug connection (seal the power plug side with a protective cap when expected to come into contact with coolant/lubricant or contamination, with contamination level according to EN 50178:2); ⑤ Replace the motor (it must be replaced with a motor of the same model, which is the only way to ensure that all parameters do not need to be modified and that the "integrated safety technology" function does not require repeated acceptance); ⑥ Re establish the plug-in connection; ⑦ Re establish the dimensional benchmark. Warning: When using a motor encoder as the servo axis for an indirect position measurement system, the size reference will be lost after replacing the motor, and the reference point with the machine coordinate system must be re established.
When disassembling transmission components, it is forbidden to strike the shaft end. Use a pulling tool with a gasket to protect the shaft end, and if necessary, heat the output component. The motor that is ready for storage must be disassembled and reinstalled with the protective cap (connector, shaft, liquid cooled inlet) that was delivered. The liquid cooled motor should be completely emptied of the cooling pipeline (such as compressed air blowing) to prevent freezing damage during storage below 0 ℃.
Key points of environmental protection disposal
The motor is mainly composed of steel, aluminum, copper, brass, permanent magnets (rare earth metals) and electronic components, and can be returned to Bosch Rexroth for free disposal (must be free of oil stains and foreign objects, freight collect). Dealing with major hazards: Before disassembly, permanent magnets must undergo heat treatment to demagnetize, and the transportation of magnetic rotors is prohibited - permanent magnets pose a health hazard to pacemaker/implant wearers, pose a risk of strong attraction and finger injury, and may damage magnetic sensitive items such as watches and bank cards. Plastic parts labeled with flame retardants according to EN ISO 1043 must be separately recycled; Batteries are returned to the recycling systems of various countries in accordance with the EU Directive 2006/66/EC.