Eaton K-Series Digitrip OPTIM Circuit Breakers: A Comprehensive Guide to Installation, Configuration, and Testing

Product Overview and Technical Specifications

1.1 Applicable models and rated values

The K series OPTIM circuit breakers include the following models:

KD/HKD/KDC: Standard and high breaking types, suitable for 600 Vac systems

CKD/CHKD: 100% rated continuous current type, suitable for high load continuous operation scenarios

Rated current range: 125A, 250A, 400A (adjusted through rated plug)

1.2 Compliance with standards

UL 489: Aged Case Circuit Breaker Standard

IEC 157-1: International Standard for Low Voltage Circuit Breakers

NEC Article 230-95: Requirements for Installation and Testing of Grounding Fault Protection System

1.3 100% rated application instructions

CKD and CHKD models can achieve 100% continuous rated operation under the following conditions:

Use insulated wires at 90 ° C

Cooperate with AL9CU terminal

Installed in a standard cabinet with a minimum size of 24 "high x 15" wide x 6 "deep (no ventilation required)


Preparation and safety warning before installation

⚠️  Important safety tips

Before installing or maintaining equipment, it is necessary to confirm that the equipment has been powered off and comply with local safety regulations. Eaton shall not be liable for any losses caused by misuse or incorrect installation.

2.1 Open box inspection

Check if the nameplate data matches the system requirements

Check for any physical damage during transportation

Confirm that the accessory package (terminals, rated plugs, installation screws, etc.) is complete


Mechanical installation steps

3.1 Disassembling the casing

Ensure that the circuit breaker is in the "trip" or "OFF" position

Remove the cover screws and take off the front cover

3.2 Installation of rated plugs and internal accessories

The rated plug must be matched with the trip unit (see Table 2-2)

It is recommended to install internal accessories such as auxiliary switches and alarm switches before installation

3.3 Installing Terminals

Select aluminum or copper terminals based on wire type (see Table 2-1)

Use a 7/32 inch socket wrench with a torque setting of 6-8 lb ft (8-11 N · m)

3.4 Installing the Circuit Breaker Body

Drill holes in the bottom plate according to the drilling diagram in Figure 2-2

Secure with M4 or M5 screws, with a torque not exceeding 28 lb in (3 N · m)

Definition of Electrical Wiring and Control Terminals

4.1 Main circuit wiring

The wiring between cables and load terminals must be carried out according to the terminal torque table

If aluminum wires are used, it is recommended to use specialized joint compounds to prevent overheating

4.2 Definition of Control Terminals (Figure 2-5)

The OPTIM trip unit supports multiple functional interfaces, and the terminal definitions are as follows (partially):

Terminal number, signal name, function description

1 GF Alarm Ground Fault Alarm

2 Zone OUT interlocking output

3 Zone IN interlocking input

Positive pole of 6+24 Vdc control power supply

7/8 NS/NS * neutral point sensor input

15-19 Bell/Aux alarm and auxiliary switch

⚠️  Attention: The polarity of the+24 Vdc power supply must not be reversed, otherwise it may damage the electronic protection function.


Release unit configuration and communication settings

5.1 Selection of rated plugs

The rated value of the trip unit can be achieved using the rated plug

125A 63A, 70A, 90A, 100A, 110A, 125A

250A 125A, 150A, 160A, 175A, 200A, 225A, 250A

400A 200A, 225A, 250A, 300A, 350A, 400A

5.2 Parameter Setting Method

Using the handheld programmer Digittrip OPTIMZER

Or remotely set up with IMPACC software through INCOM communication module


Manual operation and reset

6.1 Position indication of handle

Red: ON

White: TRIP

Green: OFF

6.2 Reset Operation

Push the handle to the "Reset" position (OFF limit) to reset it

The reset button is only used to clear the LED fault indication and does not affect the mechanical reset

6.3 PUSH-TO-TRIP Function

Press the test button on the trip unit with a small screwdriver to simulate a faulty trip

Suggest regular operations to verify the flexibility of the institution


On site inspection and maintenance

7.1 Regular inspection items

Clean surface dust (using a lint free cloth or vacuum cleaner)

Manually switch on and off several times, check if the mechanism is flexible

Check the terminals for signs of discoloration, melting, or corrosion

Check the shell for cracks or discoloration

7.2 Grounding Fault System Performance Test (NEC 230-95 (C) Requirement)

All grounding fault protection systems must undergo performance testing during their initial installation, and test records must be filled out (Figure 4-1).

Test 1: Single phase power on test (should trip)

Apply a current of 125% of the ground fault setting value in one phase

The circuit breaker should trip within 1 second and the alarm indicator should activate

Test 2: Neutral point return test for four wire system (should not trip)

Current passes through one phase and returns through the neutral point sensor

The circuit breaker should not trip, and the alarm should not activate

Test 3: Two way electrical test for three wire system (should not trip)

  • National Instruments cRIO-9112 Chassis
  • National Instruments PXIe-1078 Chassis
  • National Instruments PCIe-6536 DIO Board
  • National Instruments NI-9425 Input Module
  • National Instruments PCI-5122 Digitizer Card
  • National Instruments 779072-01 Relay Module
  • National Instruments 783703-01 DAQ Module
  • National Instruments PXI-6515 Digital Module
  • National Instruments 781099-01 DAQ Device
  • National Instruments PXI-8183 PXI Controller
  • National Instruments sbRIO-9626 Single-Board RIO Controller
  • National Instruments PXIe-1435 Camera Link Frame Grabber
  • National Instruments NI 9237 Strain Bridge Input Module
  • National Instruments PXIe-4353 Thermocouple Input Module
  • National Instruments PCIe-6320 X Series DAQ Card
  • National Instruments NI 1454 Compact Vision System
  • National Instruments PCIe-6321 X Series DAQ Card
  • National Instruments PXIe-5172 PXI Oscilloscope Module
  • National Instruments cDAQ-9134 CompactDAQ Controller
  • National Instruments cRIO-9063 CompactRIO Controller
  • National Instruments PXI-4070 DMM Card
  • National Instruments cFP-BP-4 Backplane
  • National Instruments 779521-01 Bridge Module
  • National Instruments cDAQ-9172 Chassis
  • National Instruments NI 9236 Strain Module
  • National Instruments PXI-1042Q Chassis
  • National Instruments SCXI-1102 Input Module
  • National Instruments 776990-01 Input Module
  • National Instruments PXI-1045 PXI Chassis
  • National Instruments PCIe-6251 DAQ Device
  • National Instruments NI 9219 Universal Analog Input Module
  • National Instruments NI 9215 BNC Analog Input Module
  • National Instruments PXIe-6570 Digital Pattern Instrument
  • National Instruments NI-9477 Digital Output Module
  • National Instruments NI 9145 EtherCAT Chassis
  • National Instruments PCI-6521 Industrial Digital I/O Card
  • National Instruments NI 9239 BNC Voltage Input Module
  • National Instruments NI 9265 Current Output Module
  • National Instruments NI 9212 Thermocouple Input Module
  • National Instruments PXI-6229 Multifunction DAQ Module
  • National Instruments NI-9146 Chassis
  • National Instruments PXIe-5622 Digitizer
  • National Instruments PXI-6704 Output Module
  • National Instruments 782362-01 Input Module
  • National Instruments 779068-01 Digital Module
  • National Instruments 781063-01 Output Module
  • National Instruments PCI-7356 Motion Controller
  • National Instruments 779787-01 Input Module
  • National Instruments PXIe-1071 System
  • National Instruments NI 9219 Input Module
  • National Instruments NI 9214 Thermocouple Input Module
  • National Instruments PXIe-1085 18-Slot Chassis
  • National Instruments PCIe-6320 Multifunction DAQ Card
  • National Instruments USB-6211 Multifunction I/O Device
  • National Instruments USB-6341 X Series DAQ Device
  • National Instruments NI 9205 Analog Input Module
  • National Instruments NI 9149 8-Slot Chassis
  • National Instruments PXIe-2569 Relay Module
  • National Instruments NI 9230 Sound and Vibration Module
  • National Instruments cRIO-9047 CompactRIO Controller
  • National Instruments PCI-6534 Digital IO Card
  • National Instruments PXI-5122 Digitizer Module
  • National Instruments cDAQ-9188XT Chassis
  • National Instruments cDAQ-9184 Ethernet Chassis
  • National Instruments USB-6225 OEM DAQ Device
  • National Instruments NI 9205 Input Module
  • National Instruments NI 9207 Input Module
  • National Instruments NI-9862 CAN Module
  • National Instruments 781156-01 CAN Module
  • National Instruments FP-AO-200 Output Module
  • National Instruments NI 9264 Output Module
  • National Instruments IC-3173 Controller
  • National Instruments NI 9234 Vibration Module
  • National Instruments SMB-2163 DIO Accessory
  • National Instruments PXIe-1062Q DSA System
  • National Instruments USB-6289 DAQ Device
  • National Instruments NI 9233 Vibration Module
  • National Instruments PXIe-5840 VST
  • National Instruments PXI-1033 and PXI-6132 System
  • National Instruments GPIB-USB-HS+ Controller
  • National Instruments NI 9231 Sound and Vibration Module
  • National Instruments cRIO-9074 CompactRIO Controller
  • National Instruments 782536-01 DAQ Module
  • National Instruments 779781-01 DAQ Module
  • National Instruments PXIe-8388 MXI Express Controller
  • National Instruments SCXI-1520 Strain Bridge Module
  • National Instruments PCIe-6320 Multifunction DAQ Card
  • National Instruments NI 9234 Sound and Vibration Module
  • National Instruments USB-4431 Sound and Vibration Device
  • National Instruments NI 9227 Current Input Module
  • National Instruments PXI-1033 PXI Chassis
  • National Instruments NI 9213 Thermocouple Module
  • National Instruments PXI-1042 PXI Chassis
  • National Instruments PXI-6229 DAQ Card
  • National Instruments cRIO-9075 Controller
  • National Instruments PCI-6033E DAQ Card
  • National Instruments PCIe-6363 DAQ Card
  • National Instruments cDAQ-9174 Chassis
  • National Instruments PXIe-8880 PXI Controller
  • National Instruments NI 9242 Analog Input Module
  • National Instruments USB-6221 BNC DAQ Device
  • National Instruments NI 9220 Analog Input Module
  • National Instruments cRIO-9068 CompactRIO Controller
  • National Instruments PXI-4130 Source Measure Unit
  • National Instruments USB-6251 Multifunction DAQ Device
  • National Instruments PXI-8106 Embedded Controller
  • National Instruments USB-6218 Multifunction DAQ Device
  • National Instruments PCIe-1473R Camera Link Frame Grabber
  • National Instruments PXIe-4341 DSA Module
  • National Instruments PXI-8102 Embedded Controller
  • National Instruments cDAQ-9178 Chassis
  • National Instruments USB-6210 DAQ Device
  • National Instruments USB-6212 DAQ Device
  • National Instruments NI 9485 Relay Output Module
  • National Instruments NI 9208 Current Input Module
  • National Instruments PXIe-4141 SMU
  • National Instruments PCI-6154 DAQ Card
  • National Instruments cRIO-9038 Controller
  • National Instruments PCI-6133 DAQ Card
  • National Instruments LabVIEW RIO Kit 501684G
  • National Instruments PXIe-6396 Embedded Controller
  • National Instruments USB-8502 CAN Interface Device
  • National Instruments NI 9264 Spring Terminal Output Module
  • National Instruments NI 9213 Thermocouple Input Module
  • National Instruments NI-9205 Analog Input Module
  • National Instruments NI 9264 Analog Output Module
  • National Instruments USB-6212 Multifunction I/O Module
  • National Instruments PXI-4071 FlexDMM Multimeter Module