Product positioning: Scalable platform for centralized and distributed control
In the field of motion control and machine automation, the choice of controller hardware platform directly determines the scalability and lifecycle cost of the project. The IndraControl L25 launched by Bosch Rexroth is a compact Motion Logic Controller belonging to the IndraControl L series. Its core design concept can be summarized into six advantages:
Scalable hardware platform;
Standardized communication interface;
Implement optional extensions through functional and technical modules;
Ideal adaptation to centralized and distributed control topologies;
Can be independently extended and combined with high-quality visualization components;
Modular I/O unit.
L25 runs two system layers simultaneously: IndraMotion MLC (controller based motion logic system) and IndraLogic XLC (PLC system), which means that one L25 can simultaneously handle motion sequence logic and conventional PLC logic processing tasks without the need for a separate hardware architecture of motion controller and PLC.
Detailed explanation of core technical specifications
2.1 Processor and Memory
Project L25 Specification
CPU Renesas SH 7785 (dual core architecture)
Real time clock integration
Application Memory 128 MB
Retained memory 256 kB
Flash capacity 1 MB/total 1 GB
The Renesas SH 7785 dual core processor is the computing foundation of L25: one core is dedicated to real-time motion tasks, while the other core handles PLC logic and communication, ensuring the determinacy of motion cycles. 256 kB of persistent memory is used to hold key variables and recipe data after power failure, while 1 GB of Flash provides ample storage space for applications and firmware.
2.2 Display and Operation
The front of the device is equipped with an LCD single line display screen and 4 operation keys, which can display the running status (such as "5 RUN"), error codes, and diagnostic information in real time - this "locally minimized human-machine interface" design allows maintenance personnel to quickly determine the health status of the controller without connecting to a programming PC.
2.3 Communication and Diagnosis
Standard interface: 1 x Ethernet TCP/IP; 1 x Ready contact (output device ready status to the outside world);
Diagnostic mechanism: Powerfail (power failure record), Watchdog (watchdog monitoring), Temperature monitoring - Triple diagnosis covers the most common sources of power supply, software, and heat.
2.4 I/O and Fieldbus
I/O capability: up to 256 usage channels; I/O expansion can accommodate up to 63 Inline modules and up to 64 bytes. L25 extends I/O through the Rexroth Inline system, which shares the same ecology as Phoenix Contact Inline I/O and can reuse a complete set of modules such as digital/analog/temperature/safety.
Fieldbus options (both master/dual role capabilities):
Bus configuration
Sercos III 1 × (option)
PROFINET 1 × PROFINET IO Controller/- Device (option)
EtherNet/IP 1 x scanner/adapter (option)
PROFIBUS 1 x PROFIBUS DP Master/Slave (option)
The dual roles of PROFINET IO Controller/Device and PROFIBUS DP Master/Slave are the key differentiating capabilities of L25: the controller can manage its own I/O ring as the master station, or be attached to the upper PLC/CNC as a slave station - very suitable for "transition upgrade" scenarios (the upper system remains unchanged, and the lower layer gradually modernizes).
Electrical specifications and power supply system
The power supply design of L25 reflects the segmented power supply concept of the Inline system:
Power input U: 24 V DC, range 19-30 V DC, residual ripple ± 5%;
Logic power supply UL: 7.5 V (converted from external 24 V DC), maximum 2 A;
Logic segment power supply ULS: 24 V DC, tolerance -25%...+30%, maximum 2A;
Analog power supply UANA: 24 V DC, maximum 0.5 A;
Segment voltage US/main power supply UM: 24 V DC, tolerance -15%...+20%, maximum 8 A (Um+Us total);
Power consumption of the whole machine: 8.7 W.
Understanding this power supply hierarchy is crucial: the total of 8 A between UM (main power supply) and US (segment voltage) determines the load budget for subsequent Inline segments - when planning the number of expansion modules, the sum of power consumption of each module must be calculated to avoid overload.

Mechanical and environmental conditions
Project specifications
Dimensions (H × B × T) 120 × 175.4 × 84.7 mm
Weight 0.64 kg
Protection level IP20
Vibration tolerance 1 g
Impact resistance 15 g
Certification CE/UL/CSA
Operating temperature+5 ° C to+55 ° C
Operating humidity ranges from 5% to 95%, EN 61131-2
The 0.64 kg lightweight body and 175 mm width make the L25 suitable for compact control cabinet installation; +The operating limit of 55 ° C covers the majority of industrial cabinet environments, but for outdoor or high-temperature situations, the heat load inside the cabinet still needs to be calculated.
Function extension: CFL functional module system
The IndraControl L platform achieves on-demand expansion through CFL function modules. The currently available function modules include:
Functional module capability
Fast I/O Fast I/O Processing
Real time Ethernet and PROFIBUS Real time Ethernet and PROFIBUS Communication Expansion
Programmable limit switch
Cross communication across controllers
Sercos III SERCOS III Fiber Real time Bus
This modular expansion strategy enables L25 to be smoothly upgraded from a simple centralized controller to the hub of a complex motion system - for example, to achieve collaboration between multiple L25's through the Cross communication module, or to support cam positioning requirements in high-speed printing and packaging machinery through the Programmable limit switch.
Order information and model decoding
6.1 Controller body
Type code description order number
CML25.1-PN-400-NN-NNC1-NW IndraControl L25,RT Ethernet + PROFIBUS, Configurable fieldbus interface R911172155
CML25.1-3N-400-NN-NNC1-NW IndraControl L25,Sercos III R911171363
Interpretation of Model Field: CML25.1 refers to the product line and version; PN=Real time Ethernet+PROFIBUS combination, 3N=Sercos III; 400 is the performance level; NNC1/NW is the firmware and delivery status suffix. When selecting, it is necessary to decide based on the fieldbus ecosystem: PN type is selected for existing PROFIBUS/PROFINET networks, and 3N type is selected for SERCOS fiber optic drive ecosystems.
6.2 Accessories
Type code description order number
R-IB IL SCN-PWR IN-PWR power connector R911171765
R-IB IL Field 2 Identification Field (Narrow) R911289341
R-IB IL Field 8 Identification Field (Width) R911289342
System selection suggestions and application scenarios
Typical scenarios suitable for L25 include:
Single machine motion control: equipped with IndraDrive drive (Sercos III 3N type) to build a compact multi axis machine;
Centralized control cabinet solution: Covering all I/O requirements of medium-sized equipment with an expansion limit of 63 Inline modules;
Distributed topology: Utilizing the dual role capabilities of PROFINET/EtherNet/IP, L25 is integrated as a slave into the higher-level factory network;
Machine upgrade and renovation: Replace the old PLC+motion control dual hardware solution, integrate logic with an L25+IndraLogic XLC/IndraMotion MLC software stack, and reduce spare parts and training costs;
Visual extension: Combined with IndraControl VCP series operation terminals or standard visualization components, achieve a complete machine HMI solution.
Selection checklist: ① Fieldbus type and role (master/slave); ② Is the number of I/O points within the budget of 256 channels/64 bytes; ③ Is the total power consumption of each Inline segment less than 8 A? ④ Is CFL function module (such as fast I/O or programmable limit) required; ⑤ Whether the temperature inside the cabinet meets+5...+55 ° C.
Maintenance and shutdown precautions
Based on the diagnostic design in the specification table, daily maintenance should focus on:
Temperature monitoring alarm: Clean the heat dissipation surface in a timely manner, verify the ambient temperature and convection inside the cabinet;
Powerfail record: Check the power supply quality (ripple within ± 5%, voltage 19-30 V DC);
Watchdog trigger: mostly due to program dead loop or firmware exception, requiring a read back of diagnostic logs;
Retention data: The recipe/counter data stored in the 256 kB Remanent area should be fully migrated when replacing the controller;
Aging management: According to the manufacturer's instructions, the product undergoes natural wear and aging processes - the document clearly states that the data is only a product description and does not exempt the user from the obligation of self judgment and verification.