Rexroth IndraDyn H Spindle Motor Planning Guide

F: | Au:FANS | DA:2026-11-23 | 120 Br: | 🔊 点击朗读正文 ❚❚ ▶ | Share:

Rexroth IndraDyn H frameless synchronous spindle motor: full process guide for project planning, installation, and commissioning

Product positioning and technical background

In the field of modern high-speed machining, machine tools have increasingly stringent requirements for the acceleration, speed, and accuracy of motors. The IndraDyn H series high-speed synchronous frameless motors launched by Bosch Rexroth are a new generation of kit motors designed to meet the core requirement of "outputting high torque at high speeds".

This series of motors consists of a stator with three-phase windings and a rotor with built-in permanent magnets, possessing the following key technical features:

Wide constant power range: from 10.1 kW for the 102 specification to 97.9 kW for the 312 specification, covering the rated torque range of 12 Nm to 2750 Nm;

Short start-up time and low rotor temperature: very suitable for motor spindle applications;

The built-in self circulating cooling system in the motor reduces the additional costs for machine tool manufacturers while improving cooling efficiency and capacity.

Typical applications are concentrated in the direct drive electric spindle of the machine tool industry - the motor is placed between the main bearings, giving the electric spindle extremely high stiffness, allowing only one driver to simultaneously drive the spindle and C-axis in equipment such as grinders. Electric spindles are widely used in turning, milling, and grinding processes, involving fields such as machine tools, transmission lines, machining centers, and specialized equipment.

Product specification system and selection key points

IndraDyn H offers nine machine base specifications ranging from 102 to 382, each with multiple machine base lengths (A, B, D, F, J, H) and winding codes. The rotor and stator are independent kits with separate model codes (rotor MRS, stator MSS), and the "2" in the sixth digit code is used to distinguish IndraDyn H from the early MBS series.

When selecting, it is important to pay attention to the following parameters:

Rated torque and rated speed: For example, the rated torque of Size 162 is 50-120 Nm, and the rated speed is 2000-4000 rpm; Size 102 can reach up to 30000 rpm;

Maximum torque and maximum current: The maximum torque depends on the driving controller used; If the controller cannot optimize the input control angle, the reluctance torque cannot be utilized, and the rated torque will be reduced by 10-15%;

Thermal time constant Tth: Under liquid cooling conditions, it is usually 5-10 minutes (depending on specifications), which affects the design of overload curves;

Liquid cooling parameters: The inlet temperature of the coolant must be maintained at+10...+40 ° C, the design value of the coolant temperature rise Δ T is 10 K, and the maximum inlet pressure is 5 bar.

It is worth noting that the reference voltage is 540 VDC; If the actual bus voltage is different (such as 750 VDC), the characteristic curve can be linearly extrapolated and converted: the torque remains unchanged, and the speed is scaled proportionally according to the voltage (nmax, 750V=750/540 × nmax).


Application boundary and environmental conditions

According to the manual requirements, the motor calibration performance is based on the following conditions:

The ambient temperature ranges from 0 ° C to+40 ° C;

Install at an altitude of 0-1000 meters.

When exceeding the range, the motor data needs to be downgraded according to the temperature utilization coefficient fT and altitude utilization coefficient fH; When both exceed the limit, it is necessary to multiply fT by fH and then multiply by the selection data.

It is recommended to design according to the 3K4 level of DIN EN 60721-3-3 for humidity conditions (high relative humidity of 95%, maximum absolute humidity of 29 g/m ³, temperature change rate of 0.5 ° C/min).

The taboo usage scenarios that must be emphasized include underwater operation, extreme temperature fluctuations or ultra-high temperature environments, and any use without explicit permission from Bosch Rexroth. The protection level of the electric spindle is IP00 (IEC 60529), so the casing manufacturer must take their own responsibility for moisture-proof, anti-corrosion, and cutting fluid intrusion protection measures - in high humidity environments, high-pressure cleaning, or environments containing cooling lubricants, winding insulation damage may result in irreparable scrapping of the motor.


Principle of hot sleeve assembly between rotor and spindle

The IndraDyn H rotor is connected to the main shaft through a shrink fit, and there are two designs:

1N design (smooth inner hole): Multiple mating surfaces with slight diameter gradients are arranged in sequence on the spindle, and are aligned through friction. The advantage is that the structure is more compact and can accommodate a larger rotor inner diameter in the same space; The disadvantage is that once the hot sleeve is completed, the rotor cannot be disassembled without damage.

2N design (stepped interference fit): The spindle has two stepped mating surfaces (Ø D1>Ø D2), and the rotor is equipped with O-ring seals and pressure oil interfaces. Inject high-pressure oil into the mating surface during disassembly to form an oil film ("floating" effect), allowing the rotor to slide out axially - this is a key capability in maintenance situations.

Hot sleeve assembly process (compatible with 1N and 2N)

Heating rotor: Heat the rotor in the heating cabinet to at least+135 ° C, and strictly prohibit exceeding+145 ° C - exceeding this temperature will damage the permanent magnets inside the rotor, and the temperature must be monitored throughout the process;

Cooling spindle: cool to -20 ° C, while paying attention to wearing protective gloves for ultra-low temperature components;

Quick assembly: Quickly slide the spindle into the rotor placed in the non-magnetic fixture. Under normal circumstances, the spindle slides into the endpoint by its own weight; If it is not in place, an external force not exceeding 500 N (approximately equal to the weight of the assembly worker) can be applied;

After cooling to room temperature, check: visually confirm that the spindle is in its final position; Check whether the coaxiality of the spindle has deteriorated - the stress during the cooling process may cause slight deformation of the spindle;

Rotor balance: Adjust the balance by using threaded pins on the balance ring to achieve the target vibration level (EN 60034-14:2004). The threaded pins must be fixed with LOCTITE 620 and material removal from the balance ring is strictly prohibited.

Special treatment of 2N rotor

Before assembly, lubricate the O-ring and place it in the rotor groove (do not twist); After assembly, seal the pressure oil interface with threaded pins and LOCTITE 620 to ensure complete sealing of the oil pressure. In terms of fault handling: If the main shaft gets stuck during the hot fitting process, the rotor can be pushed out with high-pressure oil (300 mm ²/s viscosity) after cooling, and the interference tolerance can be checked and deburred before re heating; If the main shaft is warped after hot fitting, the "floating" process can also be used to release the fitting stress. Attention: Within 24 hours after heating, do not allow the ladder to withstand full load.

Stator installation and electrical connection

Stator installation specifications

Install the stator axially into the spindle housing and lift it with a lifting device (parallel chain or rope). It is absolutely forbidden to pull or push the cable bundle as an installation aid;

When tightening, it is only allowed to fix on one side of A or B - at least 1 mm gap must be reserved on the other side for longitudinal expansion during operation and heating;

Tightening torque for each specification: MSS162/182/202 is M6 × 12 (6-10 pieces, 14-16 Nm), MSS242-382 is M8 series bolt (12-18 pieces, 34-38 Nm);

The edge of the cable through-hole on the spindle housing must be chamfered or deburred, and the bending radius of the cable must not be less than the minimum bending radius.

Grounding and power connection

The grounding requirements are very strict: when the leakage current during normal operation exceeds 3.5 mA, a copper conductor with a total cross-sectional area of not less than 10 mm ² must be used for permanent grounding. The ring terminal must be fixed to the stator end face with M6 or M8 brass screws, and the contact surface must be cleaned to a shiny metal and coated with Vaseline for corrosion protection.

There are two ways to connect the power supply:

Terminal box method: connected through three pole or six pole terminal blocks, must meet standards such as DIN 46 294/DIN VDE 0110/DIN 46 237, with a protection level of at least IP54 (IP65 is recommended for the terminal box body), and pay attention to component selection under high bus voltage of 750 VDC;

Coupling (flange socket) method: INS0382/LXX or INS0482/LXX bayonet connector, insert according to the code alignment, manually tighten until you hear a locking "click" sound, align the flange seat with the red mark on the plug, and it is locked in place.

Recommend using Rexroth prefabricated cables - pre wired without treatment, resistant to mineral oil/grease/bio oil, silicon free and halogen-free, UL/CSA certified, combustion characteristics meet VDE 0472-804, comply with EMC guidelines, and have a protection level of up to IP67. Self assembling cables or third-party cable systems may not meet the above standards, and manufacturers are not responsible for any resulting malfunctions.

Temperature sensor dual system

The stator is equipped with two types of sensors:

PTC SNM.150.DK (motor protection sensor): rated operating temperature of 150 ° C, connected to the drive control device for overheat protection. It must be connected, otherwise the motor will not be protected from heat; And PTC sensors are not safety devices and cannot be used in safety systems for personnel or machine protection;

KTY84-130 (temperature monitoring sensor): Approximately 577 Ω at 25 ° C, 1000 Ω at 100 ° C, continuous current of 2 mA, for outdoor monitoring of winding temperature by the user. When connecting, attention should be paid to polarity, and the relationship between temperature and resistance can be converted through a fourth degree polynomial.


Key points of liquid cooling system design

IndraDyn H motors must operate with guaranteed coolant supply - no liquid cooling operation is prohibited.

Coolant requirements

All technical data is cooled by water, and data must be recalculated when using other media;

Prohibit the use of hard tap water (which is prone to scaling and damaging the motor and cooling system);

Anti corrosion additives that are compatible with the mixed installation of copper (cooling pipelines) and brass (joints) must be added;

Recommend using a closed-loop circuit and configuring a 100 μ m fine filter;

Prohibit the use of cutting lubricants generated during machining as cooling media;

Avoid contamination of the cooling medium and drift of chemical composition and pH value.

The setting of the coolant inlet temperature should be combined with the ambient temperature to prevent condensation: the minimum temperature that can be set should not be lower than 5 ° C below the ambient temperature. For example, when the ambient temperature is 20 ° C, the inlet temperature should be set at+15...+40 ° C.

Cooling circuit calculation

Flow rate: Q=Pco × 60000/(c ·ρ·Δ T), determined based on power loss corresponding to rated torque and 10 K temperature rise;

Pressure drop: Δ p=p1 − p2, which increases nonlinearly with the increase of flow rate. The total pressure drop of the system is composed of the pressure drops of various components such as motors, pipelines, and joints, which must be taken into account when selecting pumps;

Non aqueous medium torque reduction: kcred=√ (cx ·ρ x/(cw ·ρ w)) × 100%. If using heat transfer oil (c=1000 J/kg · K, ρ=887 kg/m ³), the torque availability relative to water will significantly decrease.

Series parallel connection of cooling system

Parallel connection: Each component can be cooled according to its own required flow rate, with consistent inlet temperature and pressure difference, and high thermal operation reliability - preferred for multi-component systems;

Series connection: When the same flow passes through all components, the accumulated pressure drop leads to an increase in system pressure, and the inlet temperature of downstream components gradually rises, resulting in uneven heating of the machine; Only applicable when the flow demand is similar, the pressure drop is small, or far away from the cold source;

The combination of serial and parallel can take into account the advantages of both methods.

Thermal removal equipment is divided into three categories: gas-liquid cooling units (temperature control accuracy ± 5K, suitable for independent machine tools without upstream cooling circuits), liquid-liquid cooling units (± 5K, suitable for systems with existing central feedback coolers), and refrigeration cooling units (± 1K, suitable for high-precision machining and other situations that require high thermal stability). Flow, pressure, and temperature monitoring systems should be installed in the cooling circuit.


Debugging process and key parameters

Due to the lack of parameter memory for frameless motors, all motor parameters must be manually entered or loaded during debugging (DriveTop debugging software can provide all Bosch Rexroth motor parameters). The core Sercos parameters include: pole number (P-0-0018), torque constant (P-0-0051), d/q-axis inductance (P-0-4016/4017), stator resistance (P-0-4048), encoder resolution (S-0-0116), etc. After inputting the motor parameters, it is not possible to immediately power on - the encoder parameter input, encoder polarity check, and commutation adjustment need to be completed first.

Encoder polarity

The effective direction of motor torque must be consistent with the counting direction of the encoder, otherwise uncontrolled motion will occur when powered on. Select polarity through S-0-0277 (position encoder type 1, Bit 3), and set all zeros for S-0-0085 (torque polarity), S-0-0043 (speed polarity), and S-0-0055 (position polarity). After setting, it must be verified that the encoder outputs a positive signal when the motor rotates clockwise.

Reversing adjustment

Reversing adjustment is the process of establishing a reference for the relative position of the rotor to the stator, ensuring that the stator current vector and rotor magnetic flux vector always maintain a 90 ° angle, thereby outputting the maximum constant torque. The following situations must be executed: debugging startup, change of mechanical connection method of encoder, replacement of encoder, change of mechanical connection of stator or rotor. Absolute encoders (such as Rexroth DSF/HSF) only need to perform one commutation adjustment during initial debugging; The incremental encoder needs to be executed every time it is powered on.

Control loop tuning

Debugging is carried out in the cascade order of "current loop (with motor parameters) → speed loop optimization → position loop optimization → acceleration feedforward". If there is mechanical resonance ("double mass oscillation" often occurs between 400-800 Hz), it can be selectively suppressed through a rejection filter: the attenuation is deepest at the notch frequency, and the bandwidth determines the attenuation range - the larger the bandwidth, the shallower the attenuation at the notch frequency. After suppressing mechanical resonance, the dynamic performance of the velocity and position loops can be further improved, resulting in higher contour accuracy and shorter positioning cycles.


Operation, maintenance, and troubleshooting

Maintenance Strategy

The IndraDyn H motor body is maintenance free, but preventive inspections should be performed within the overall maintenance cycle:

Measure interval

Check the cooling system function according to the overall plan, at least every 1000 operating hours

Check mechanical and electrical connections at least every 1000 operating hours

Check for smooth operation, vibration, and bearing noise at least every 1000 operating hours

Clean the motor casing, heat dissipation surface, and joint dust according to the degree of pollution, at the latest once a year

Typical faults and their handling

Excessive casing temperature: Possible reasons may include cooling system failure, changes in machining cycles, modified motor parameters, or bearing wear. Disposal includes checking/flushing the cooling circuit, reviewing the layout of the drive load, and restoring the original parameters. Special attention: After the cooling system of the liquid cooled motor fails, do not immediately restart or use low-temperature coolant - thermal shock can cause damage, wait for the motor temperature to drop to about 40 ° C before restarting.

The winding temperature reading is abnormally high but the casing temperature is normal: it is mostly due to sensor wiring errors/disconnections, diagnostic system failures, or PTC failures. The resistance of the sensor can be checked by comparing the characteristic curve with the resistance range of a multimeter (KTY84-130 should be 1000 Ω at 100 ° C).

Motor or machine tool vibration: investigate factors such as poor coupling/damage, expired bearing life, loose installation, unstable control system, etc; Damaged components must not be used again.

Position instruction not received: Common reasons include encoder cable wiring errors or misplaced pins, insufficient shielding, encoder parameter errors, loose mechanical connections, or encoder itself faults. Suggest restoring the original parameter values according to the debugging report.

Electrical testing

Electrical faults can be determined through measurement: the resistance and electrical induction between phases 1-2, 2-3, and 1-3 are consistent with each other (with an error within a specific tolerance); The insulation resistance to ground should not be less than 1 M Ω. If the difference is significant, there may be phase to phase short circuits, turn to turn faults, or ground short circuits. Bosch Rexroth customer service should be contacted.


Summary of Safety Notice Points

The safety requirements that run through the entire lifecycle include:

Risk of strong magnetic field: The rotor permanent magnet generates a strong magnetic field, and wearers of pacemakers, metal implants, and hearing aids are not allowed to enter the relevant areas; Watches, credit cards, and magnetic stripe media must be kept away from magnetic components; The ferromagnetic fixture and worktable will adsorb the rotor, and non-magnetic materials must be used;

Electrical safety: When operating live parts above 50 V, power must be disconnected; The waiting time for capacitor discharge is at least 30 minutes; Electric drives must not use residual current protection devices (RCD) and must use overcurrent protection devices to prevent indirect contact;

Dangerous motion protection: Parameter input errors, wiring errors, software failures, etc. can all lead to accidental movements; The vertical axis must be equipped with mechanical locking, external braking/holding brakes, or balancing measures - standard motor holding brakes or driver direct control holding brakes are not sufficient to ensure personal safety;

Hot set operation: Both 135-145 ° C hot rotor and -20 ° C cold spindle require heat-resistant/antifreeze protective equipment;

Hydraulic operation: Only manual oil pump is allowed for dismantling the 2N rotor (ensuring that the pressure immediately returns to zero in case of leakage), and a safety valve is installed to prevent the oil pressure from exceeding 1500 bar.

  • Rexroth VCP25.1BVN-003PB-NN-PW Operator Panel
  • Rexroth RKL4305/002.5 Power Cable L=250cm
  • Rexroth MSM031C-0300-NN-M5-MH1 R911344216 Servomotor
  • Rexroth CSH01.1C-SE-EN2 R911335435 Control Unit
  • Rexroth FEM-E-S 25x10RX3-4 R151224013 Ball Screw
  • Rexroth FCS01.1E-W0005-A-04-NNBV Frequency Drive
  • Rexroth 0510-425-009 Hydraulic Gear Pump
  • Bosch Rexroth IndraControl XM42 Controller R911396964
  • Rexroth VT5035-17 R900579497 Valve Amplifier
  • Rexroth FCS01-1EW0015-A-04 R91131106 Frequency Drive
  • Rexroth MSK050B-0600-NN-M1-UG1-NNN Motor
  • Bosch Indramat TBM1.2-40-W1-115 Bleeder
  • Rexroth HCS01.1E-W0028 Compact Converter
  • Rexroth Indramat MAC071B-0-PS-2-C/095-A-0 Motor
  • Rexroth HCS02.1E-W0012-A-03-NNNN Drive Set
  • Rexroth R-IL S3 BK DI8 DO4-PAC Coupler
  • Rexroth HCS01.1E-W0028-A-03-E-S3-EC-NNN Drive
  • Rexroth MSK061C-0600-NN-S1-UG0-NNNN Motor
  • Bosch Rexroth MSM041B-0300-NN-M0-CH0 Motor
  • Rexroth IKG0071-05.0m Servo Motor Cable
  • Rexroth R-IL S3 BK DI8 DO4-PAC Bus Coupler
  • Bosch Rexroth SB301 Tightening Unit 0608701017
  • Rexroth E-003-S-S Tool Cable 0608740220
  • Rexroth MSM020B-0300-NN-M0-CG0 Servo Motor
  • Rexroth IndraControl VEP30.3 Panel PC
  • Rexroth DBETE-62/315G24K31A1V Valve R901029969
  • Rexroth CSH01.3C-ET-ENS-NNN Control Section
  • Rexroth VT3013-37 Amplifier Control Card
  • Rexroth 1-2 TH6 L 162-10/N 05 Joystick
  • Rexroth ESV025 Handheld Nutrunner 0608841037
  • Rexroth RK2 S30 Amplifier Card VT 4224 U 261
  • Rexroth CDB01.1C-SE-ENS R911308279 Control Unit
  • Rexroth VFC3610-0K40-3P4-MNA-7P Inverter 0.4kW
  • Bosch Indramat HCS02.1E-W0028-A-03-NNNN Servo Module
  • Rexroth DKC01.3-040-7-FW EcoDrive R911279426
  • Rexroth HMV02.1R-W0015-A-07-NNN Utility Unit 15kW
  • Rexroth 0 608 830 193 ZSE220 Communication Module
  • Rexroth VT5003 S41 R5 Proportional Amplifier Card
  • Rexroth KSM02.1B-041c-42N-M1-HP0-ET-L3-D7-NN-FW Motor Drive
  • Mannesmann Rexroth VT5005 S16 R1 Valve Amplifier Card
  • Rexroth CFL01.1-R3 Sercos III Interface Module
  • Rexroth CKK-110-NN-1 Linear Axis with MSK040C
  • Bosch Rexroth 047018-104401 Controller Card
  • Rexroth MDSD1K-2X/4 Solenoid Driver Module
  • Rexroth DKC02.3-012-3-MGP-01VRS Servo Drive
  • Rexroth HCS01.1E-W0006 Compact Servo Drive
  • Rexroth NAM1.2-08 Line Former R911246505
  • Rexroth VPB40 Industrial PC Control Cabinet
  • Rexroth FWA-ECODR3-SGP-03-MS Firmware Module
  • Rexroth HEDE10-31 Pressure Switch R901425475
  • Rexroth HM 17-11/315-C/V0/0 Pressure Sensor
  • Rexroth VFC 3610-2K20-3P4-MNA-7P Inverter 2.2kW
  • Rexroth MSK040C-0600-NN-M1-UG1-NNNN Right Angle Geared Motor
  • Rexroth DKC02.3-012-3-MGP-01VRS EcoDrive Cs
  • Bosch Rexroth MSM031C-0300-NN-M0-CH0 Servo Motor
  • Rexroth HCS02.1E-W0012-A-03-NNNN Power Section
  • Rexroth DBDS 20 P18/400V Pressure Relief Valve
  • Rexroth 3460565500 Pneumatic EP Converter Regulator
  • Rexroth VT-SWA-1-12/DFEE Angle Sensor R900913641
  • Rexroth 0-608-830-250 Interface Module SM24V
  • Rexroth MHD071B-035-NP0-UN8 Servo Motor 12Nm 1000rpm
  • Rexroth MKD025B-144-KG0-KN R911263737 Servo Motor
  • Rexroth KCU02.2N-ET-ET*-025-NN-N-NN-NW Control Unit
  • Rexroth MV-VPB40*3-RB001VPB R911337529 Valve Terminal
  • Bosch Rexroth AS 2/R-2200 Drive Module 3842998041
  • Rexroth HMS01.1N-W0036 Power Section
  • Rexroth CKK-145-NN1 Compact Linear Module
  • Rexroth MS2N04-C0BTN-BSDK0-NNNNN-NN Geared Servo Motor
  • Rexroth HCS02.1E-W0028-A-03-NNNN Power Section
  • Rexroth MS2N04-D0BQN-CMSG0-NNNNN-NN Servo Motor
  • Rexroth MSM031C-0300-NN-M0-CH0 Servo Motor
  • Rexroth MKD041B-144-KP1-KN Servo Motor R911262307
  • Rexroth ESA075G Handheld Nutrunner 0608841033
  • Rexroth MSK070D-0450-NN-M1-UP1-NSNN Motor
  • Rexroth CKK-145-NNG1 Linear Kit with HCS02 Drive
  • Rexroth MSK060C-0300-NN-M1-UG0-NNNN Servo Motor
  • Rexroth MKD090B-047-KP1-KS Servo Motor
  • Rexroth MLS140S-3A-0450-NNN Linear Motor
  • Rexroth VPB40.3 Industrial PC R911338689 CB1
  • Rexroth HCS02.1E-W0012 Servo Drive R911313871
  • Rexroth R151349014 R151145672 Ball Screw Assembly
  • Bosch Rexroth CKK-110-NN-1 Compact Module
  • Rexroth MSK060B-0300-NN-M1-UG1-NNNN Servo Motor
  • Rexroth Indramat TBM 1.2-40-W1-024 Servo Bleeder
  • Rexroth MSK040B-0600-NN-M1-UG1-NNNN Servo Motor
  • Rexroth MLS200S-3A-0450-NNN R911299213 Linear Motor
  • Rexroth SB356 Tool Tightening Controller Rack
  • Rexroth MSK050C-0300-NN-M1-UG0-NNNN Servo Motor
  • Rexroth Indramat DKC11.3-040-7-FW Eco Drive
  • Rexroth VT2000 Proportional Amplifier
  • Rexroth VT1118-10 Analog Module
  • Rexroth MSK060C-0600-NN-M1-UP1-NSNN Motor
  • Rexroth MSK060C-0300-NN-S1-UG0-NNNN Motor
  • Rexroth R911173937 IndraControl XM AI1
  • Rexroth R412018225 AES-D-BC-ECAT Module
  • Rexroth CDB02.1B R911338542 Controller Card
  • Rexroth VT-HNC100-2-30/P-I-00/000 Module
  • Bosch Rexroth CSB02.1B R911372549 Control
  • Bosch Rexroth R185321310 Runner Block
  • Rexroth VPB40.3 Industrial PC R911338689
  • Rexroth HNK01.1A-A075-E0106-A-500 Drive Controller
  • Rexroth CSH02.1B-CC-EC-ET-S4-NN-NN-FW Controller
  • Rexroth CSB01.1C-PB-ENS-NNN Control Unit
  • Rexroth MKD041B-144-KP0-KN Permanent Magnet Motor
  • Rexroth SE-B2.020.030-14.000 Servo Motor
  • Rexroth MSK060C-0600-NN-M1-UG0-NNNN Servo Motor
  • Rexroth HCS01.1E-W0018-A-03-B Drive Controller
  • Rexroth 3 842 547 996 IE3 Geared Motor
  • Rexroth CSH01.1C-NN-ENS R911309709 Control Section
  • Rexroth R151349013 Ball Screw Nut
  • Mannesmann Rexroth VT3006-36 Analog Amplifier Card
  • Bosch Rexroth R900086160 PGF1 Gear Pump
  • Bosch Rexroth R911173263 VDP15.3 Touch Display
  • Bosch Rexroth PPC-R22.1 RJ522 Industrial Controller
  • Bosch Rexroth MSK060C-0300-NN-S1-UG0-NNNN Servo Motor
  • Bosch Rexroth R911325068 NYS04.1 Controller
  • Bosch Rexroth R911335439 CSH01.1C Control Unit
  • Bosch Rexroth R917010287 BODAS RC10 Controller
  • Bosch Rexroth R911329791 CSH01.1C Drive Controller
  • Bosch Rexroth R182432310 Runner Block Guide
  • Bosch Rexroth VT-VSPA2-1-11 Amplifier Card R900021909
  • Bosch Rexroth MKD090B-047-KG1-KN Servo Motor
  • Bosch Rexroth LTU350 Servo Amplifier 0608750108
  • Bosch Rexroth 5610102050 Pneumatic Vacuum Regulator
  • Bosch Rexroth VT5041-23/3-OV PLC Control Board
  • Bosch Rexroth VT3015 S10/E Servo Amplifier Board
  • Bosch Rexroth MSK070D-0300-NN-M2-UG1 Servo Motor
  • Bosch Rexroth 3DREP6C-21 Valve R900955887