DBG60B operation panel: displays speed, current, status information, parameters, and variable values. Its' user menu 'function allows customization of commonly used parameter lists.
Parameter management:
The equipment has a huge parameter system (P000-P96_), covering all aspects such as set values, slopes, control parameters, motor parameters, monitoring, terminal allocation, communication, etc. DBG60B supports parameter copying function, which can quickly copy the complete parameter set of one device to another device, greatly improving batch debugging efficiency.
Fault diagnosis and handling:
Fault Memory (P080): Stores detailed snapshots of the last 5 faults, including their current status, current, temperature, etc., for easy traceability and analysis.
Fault response classification: divided into "immediate shutdown", "quick stop", and "emergency stop", corresponding to different braking strategies.
Fault reset method: can be powered off and restarted, manually reset through specified binary input signal, or set to automatic reset in software (use with caution).
Detailed fault table: The manual provides fault descriptions, possible causes, and troubleshooting measures from code 00 to 99, which is an authoritative basis for troubleshooting (such as overcurrent, overvoltage, encoder faults, motor overheating, communication timeout, etc.).
The application of memory cards:
The pluggable memory card stores all device parameters and software. When replacing the device, simply insert the original card into the new device (ensuring that the power part and expansion card configuration are the same), and it can quickly resume operation, greatly reducing maintenance time.
Chapter 6: Technical Data and System Integration Options
Overview of Core Technical Parameters:
Environmental temperature: usually 0-50 ° C (100% load), and it needs to be downgraded as the temperature increases.
Protection level: specifications 0-3 are IP20, specifications 4-6 are IP00 (can be increased by adding a cover).
Certification: Possessing international certifications such as CE (Low Voltage Directive&EMC Directive), UL/cUL, C-Tick, etc.
Input/output characteristics: wide voltage input range, adjustable PWM frequency (4/8/12/16 kHz), supporting a wide speed range of -6000~+6000 rpm.
Detailed explanation of key options:
DEH11B/DER11B Encoder Card: Supports HIPERFACE ®、 Multiple encoders such as sine/cosine, TTL, etc. provide+12V power supply, with a maximum cable length of 100m. It can also be used as an incremental encoder for analog output or for master-slave synchronous connection.
DIO11B I/O expansion card: Provides additional analog inputs (AI2), analog outputs (AO1/AO2), binary inputs (DI10-DI17), and outputs (DO10-DO17) to expand control capabilities.
DFC11B CAN bus interface card: provides a second CAN (SBus2) interface with electrical isolation, supporting SEW MOVILINK ® And CANopen protocol.
Braking resistor (BW.../BW... - T): Multiple power and resistance options are available, depending on the specifications of the frequency converter and the braking energy calculation. The - T model has a built-in temperature switch.