WESTINGHOUSE Transformer Product Line

F: | Au:FAN | DA:2025-12-25 | 836 Br: | 🔊 点击朗读正文 ❚❚ | Share:

Voltage ratio: 110kV ± 2 × 2.5%, 121kV ± 2 × 2.5% (110kV level); 63kV, 66kV, 69kV ± 2 × 2.5% (66kV level), LV side 6.3kV, 10.5kV, 13.8kV, etc.

Loss indicators: no-load loss of 7.4kW-90kW, load loss of 35kW-457kW, no-load current of 0.20% -0.66%.

Short circuit impedance: 6.5% -19%, suitable for the operating characteristics of medium voltage power grids.

Application scenarios: Small and medium-sized power plants, 110/66kV substations, and self owned power stations of large industrial enterprises (such as heavy machinery factories and chemical industrial parks).


3. 35kV power transformer

Core types: Three phase dual winding non excited voltage regulating transformer, three-phase dual winding on load voltage regulating transformer, covering two types of applications: power transformers and distribution transformers.

Technical features: Adopting Westinghouse's exclusive calculation and verification process, the core components such as iron core, coil, body, and outlet oil tank are optimized in all dimensions, with advantages of low loss, low partial discharge, low noise, compact size, energy-saving and environmental protection, and low operation and maintenance costs.

Rated capacity: 630kVA-31500kVA, covering medium voltage distribution and industrial power supply needs.

Key parameters:

Voltage ratio: 35kV ± 2 × 2.5%, 35kV ± 3 × 2.5%, LV side 3.15kV, 6.3kV, 10.5kV, etc.

Loss indicators: no-load loss of 0.83kW-21.8kW, load loss of 7.86kW-116kW, no-load current of 0.25% -0.65%.

Short circuit impedance: 6.5% -10.0%, with Yd11 and YNd11 as the main connection groups.

Application scenarios: 35kV substations, industrial park distribution networks, and power supply hubs for large building clusters (such as new city development zones).

(2) Distribution Transformer Series (Low Voltage Distribution Terminal Equipment)

1. 20kV distribution transformer

Core type: Three phase dual winding non excited voltage regulating distribution transformer, oil immersed structure.

Technical features: No oil storage tank respirator design, avoiding contact between transformer oil and air, enhancing antioxidant capacity; The corrugated oil tank can expand and contract with changes in oil temperature, maintaining stable pressure inside the tank and enhancing reliability and corrosion resistance; The sealing element is made of high-quality acrylic rubber, which effectively resists light aging and thermal aging.

Rated capacity: 30kVA-1600kVA, suitable for urban distribution networks and low-voltage power supply in industrial parks.

Key parameters:

Voltage ratio: 20kV ± 2 × 2.5%, 0.4kV on the LV side.

Loss indicators: no-load loss of 100W-1660W, load loss of 690W-15950W, no-load current of 0.6% -2.1%.

Short circuit impedance: 5.0% -6.0%, connection group Dyn11.

Application scenarios: urban road lighting, residential communities, and power distribution systems for small and medium-sized industrial enterprises.

2. 10kV distribution transformer

Core type: Three phase dual winding non excited voltage regulating distribution transformer, oil immersed structure.

Technical features: Independently designed by integrating advanced domestic and foreign technologies, using advanced iron core laminated inclined worktable and non pre laminated iron yoke process to ensure sufficient grain orientation of cold-rolled silicon steel sheets and significantly reduce no-load losses; It has the advantages of low loss, low noise, and no need for iron core cleaning, with outstanding safety, reliability, and economy.

Rated capacity: 30kVA-2000kVA, it is the most widely used model for civil and industrial low-voltage distribution.

Key parameters:

Voltage ratio: 6.3kV, 10kV, 11kV ± 2 × 2.5%, LV side 0.4kV.

Loss indicators: no-load loss of 100W-1960W, load loss of 600W-18000W, no-load current of 0.5% -2.1%.

Short circuit impedance: 4.0% -4.5%, connection group Dyn11.

Application scenarios: Terminal power distribution scenarios such as residential communities, commercial centers, schools, hospitals, and small and medium-sized factories.

3. Amorphous alloy core distribution transformer (energy-saving special series)

Core type: 10kV three-phase double winding non excited voltage regulating distribution transformer, amorphous alloy iron core structure.

Technical features: The core adopts amorphous alloy soft magnetic material, which reduces no-load loss by more than 50% compared to traditional silicon steel sheet transformers, and has significant energy-saving effects; Adopting single-phase or three-phase five column box type iron core and foil wound low-voltage winding, it has the advantages of low loss and strong short-circuit withstand capacity, and its overall performance reaches the international advanced level.

Rated capacity: 30kVA-2000kVA, suitable for distribution scenarios with high energy-saving requirements.

Key parameters:

Voltage ratio: 6.3kV, 10kV, 11kV ± 2 × 2.5%, LV side 0.4kV.

Loss index: no-load loss 33W-750W (much lower than traditional models), load loss 600W-17400W, no-load current 0.4% -1.5%.

Short circuit impedance: 4.0% -5.0%, connection group Dyn11.

Application scenarios: green buildings, energy-saving parks, new energy supporting distribution, commercial and industrial projects sensitive to energy consumption indicators.

  • Basler D90 96801 100 PCB Card
  • Basler XR2002F Voltage Regulator (110 VAC, 48-480 Hz)
  • Basler SR8A-2B14B3A Regulator
  • Basler 9561500100 Module
  • Basler DECS-400 BE1-11 System
  • Basler DECS-100-B15 Excitation Control
  • Basler SCP 210 Frequency Controller
  • Basler SR4A-2B15B3A Static Voltage Regulator
  • Basler BE1-32R Power Relay
  • Basler PIA2400-17GM Power Interface Adapter
  • Basler MVC 232 Manual Voltage Control Module
  • Basler SSR 32-12 Static Voltage Regulator
  • Basler 5MW AVR Generator Voltage Regulator
  • Basler VR63-4B Voltage Regulator
  • Basler DECS-100-A05 AVR for Engine Generator
  • Basler DECS-100-B15 Automatic Voltage Regulator
  • Basler BE1-32R Directional Power Relay
  • Basler BE1-87B Differential Relay
  • Basler UFOV 260A Protective Module
  • Basler 9-2614-02-100 PCB Rev M
  • Basler DECS-100-B15 Digital AVR
  • Basler 9284900103 PS DECS-400N
  • Basler D4N3H1U Intertie Protection
  • Basler DECS-100-B15 A15 AVR
  • Basler KR4F Voltage Regulator
  • Basler BE26434 T14 Transformer
  • Basler SR8A-2B15B3A Regulator
  • Westinghouse 774B472A12 AR Relay
  • Basler DECS-100-B15 AVR
  • Basler XR2002F Regulator 110V
  • Basler SR125-E Static Regulator
  • Basler SSR 125-12 Regulator
  • Basler MOC2599 Motor Pot
  • Basler BE1-DFPR Feeder Relay
  • Basler CBS 305 Current Boost
  • Basler BE1-25 AutoSync
  • Basler MVC 300 Voltage Control
  • Basler BE3-25A AutoSync
  • Basler KR7FF Static Regulator
  • Basler 90-49000-100 Regulator
  • Basler 880 kVA Dry Type Transformer Specs
  • Basler Electric BE1-25 Sync-Check Relay Specs
  • Basler SSR 125-12 Voltage Regulator Specs
  • Basler Electric BE1-851 Overcurrent Relay Review
  • Basler Electric 149D930G02 Control Sub-Assembly
  • Basler Electric BE1-81O/UT Frequency Relay Specs
  • Basler Electric BE1-51/27C Overcurrent Relay
  • Basler Electric 149D956G02 Industrial Component
  • Basler Electric BE1-51A Overcurrent Relay Specs
  • Basler Electric BE1-40Q Loss of Excitation Relay
  • Basler DECS-200 Excitation Control System
  • Basler DECS-200 Voltage Regulator 56-277V AC / 125V DC
  • Basler BE1-87T Transformer Differential Relay
  • Basler RDP-110-S1 Protection Relay
  • Basler BE1-700V Digital Protective Relay
  • Basler BE1-951 Overcurrent Protection System
  • Basler DECS-300 Digital Excitation Control
  • Basler DECS-200 Digital Excitation Control
  • Basler DECS-200-1C Excitation Control System
  • Basler DECS-200-1L Digital Excitation Control
  • Basler Electric BE1-GPS Generator Protection System
  • Basler Electric DECS-200-1C Digital Excitation Controller
  • Basler Electric DECS125-15 Excitation Control with Power Module
  • Basler Electric BE1-87G Differential Relay
  • Basler Electric BE1-11 Protection System I5A3M2P2N0EA00
  • Basler Electric DECS-200-1C Excitation Control System
  • Basler Electric BE1-11g Generator Protection Relay
  • Basler Electric DECS 125-15-B2C1 V2.0.9 Excitation Control
  • Basler Electric BE1-81O/UT3ED1JA7N2F Frequency Relay
  • Basler Electric BE1-81O/UT3EE1YB7N1F Frequency Relay
  • Basler Electric DECS-200-1L Digital Excitation Control System
  • Basler DECS125-15-B2C1 Excitation Control
  • Basler 9507900205 SSR Retrofit Voltage Regulator
  • Basler BE2000E Digital Voltage Regulator
  • Basler BE1-GPS Generator Protection System
  • Basler DECS-250-CN1CN1N Digital Excitation Control
  • Basler DGC-2020 Genset Controller
  • Basler BE1-81O UT3ED1LA7N0F Frequency Relay (Variant)
  • Basler BE1-81O UT3EE1YA9S0F Frequency Relay (Variant)
  • Basler BE1-81O Over/Under Frequency Relay
  • Basler DECS125-15 Digital Excitation Control
  • Basler Electric BE1-951 Overcurrent Protection System
  • Basler Electric BE1-700V Digital Protective Relay
  • Basler Electric APR63-5 Automatic Voltage Regulator
  • Basler Electric BE1-851 Overcurrent Protection System
  • Basler Electric DECS-250-LN1SN1N Excitation Control
  • Basler Electric BE1-87T Transformer Differential Relay
  • Basler Electric DECS-200-1L Excitation Control System
  • Basler Electric 9310300100 DECS-300 Excitation Control
  • Basler Electric SSE-N 125-4.5KW Shunt Exciter Regulator
  • Basler Electric DGC-2020HD-5NS1DNSBA Genset Controller
  • Basler Electric BE1-81-O/UT3EE1JB7N1F Frequency Relay
  • Basler Electric BE1-81T1EE1WA0N1F Frequency Relay
  • Basler Electric BE1-25M1EA6PN5R1F Sync-Check Relay
  • Basler Electric BE1-GPS Generator Protection System
  • Basler Electric DECS-250-LN1SN1N Excitation Control Rev V
  • Basler Electric DECS-250-CN2CN1N Excitation Control
  • Basler Electric BE1-50/51B-207 Overcurrent Relay
  • Basler Electric DECS-300-C0N0 Excitation Control System
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric DECS-250-LN1CN1N Excitation Unit
  • Basler Electric DECS-250 LN2SA1D Excitation Unit Specs
  • Basler Electric BE1-87T Transformer Relay Review
  • Basler Electric BE1-11 Protection System
  • Basler Electric BE1-GPS100-E4N1H1N Protection System
  • Allen-Bradley 442G-MABH-R Safety Module
  • Beckhoff CX1030-0111 PLC Assembly Profile
  • FANUC IC693CPU364 PLC Module
  • Orange Denmark Type 200816 220 PLC Specs
  • OMRON C200H-SNT31 Sysmac PLC Module
  • Allen Bradley 20AB022A3AYNANC0 PowerFlex 70
  • OMRON C200HW-PCU01 Position Control Unit
  • ABB AO845A-eA Analog Output Module
  • OMRON CJ1M-CPU22 CPU Unit
  • Allen Bradley 100-E265ED11 Contactor
  • Honeywell 51304511-100 Interface Module
  • SOLEXY BXF3S0101N0018 Gateway Module
  • OMRON CJ2H-CPU65 CPU Unit
  • Automation Direct GS2-45P0 AC Drive
  • M68-2000 2-Axis Motion CNC Controller
  • OMRON CJ1M-CPU11 V3.0 PLC CPU Unit
  • OMRON CJ1W-NC413 4-Axis Positioning Controller
  • OMRON 3G2A3-PRO16 Programming Console HMI
  • Siemens 3VT8440-2AA04-2GA2 Molded Case Circuit Breaker
  • Siemens 3RT5045 Contactor Series
  • OMRON C200HS-CPU01-E SYSMAC PLC Controller
  • OMRON C500-NC103-E Positioning Control Unit
  • OMRON CJ1W-TC001 Temperature Control Unit