Product positioning: Tricon v9-v11 is a high tolerance error controller under Schneider Electric, designed specifically for safety critical applications. Its core advantage is fault tolerance, which can maintain error free control in the event of component hard or transient faults.
Core architecture: Triple Modular Redundancy (TMR) is adopted, with three independent channels executing control programs in parallel. Digital inputs and outputs are subject to majority voting through hardware/software mechanisms, while analog inputs are selected using median selection to ensure data integrity.
Key features: Supports online installation and maintenance, remote I/O expansion (up to 12 kilometers through SRXM module), enhanced diagnostic monitoring, and multi protocol communication interconnection.
International certification: Passed multiple certifications such as CSA in Canada, FM in the United States, T Ü V Rheinland in Germany, and the Nuclear Regulatory Commission (NRC) in the United States, and meets standards such as IEC 61508 (SIL 1-3) and ATEX Zone 2.
Hardware Components and Configuration
Component type, key models/parameters, core functions
The main chassis 8110 (supporting 6 sets of I/O modules) and 8120E (enhanced, supporting UCM modules) accommodate the main processor, power module, and provide I/O expansion bus
Expansion chassis 8111 (8 sets of I/O modules), 8121 (low density, supporting HART modules) to expand I/O capacity, with a distance of ≤ 30 meters from the main chassis
Remote chassis RXM 8112 supports remote I/O expansion, up to 12 kilometers away
Main processors (MP) 3006/3007 (v9.0-9.5), 3008 (v9.6-10. x), 3009 (v11. x) execute control programs, manage I/O and communication, TriBus speed up to 1000 Mbps
The power module 8310 (120 VAC/DC), 8311 (24 VDC), and 8312 (230 VAC) are designed with dual redundancy. A single module can support the entire chassis load and output 6.5 VDC
The I/O module supports analog input (3700A/3703E), digital output (3604E/3625), thermocouple input (3708E), and supports analog input (0-10 VDC/4-20 mA), digital input (24-115 VAC/DC), pulse signal acquisition and output
Communication modules TCM (supporting Ethernet/Modbus), UCM (compatible with Foxboro Evo), and HART modules (2770H/2870H) enable communication with DCS systems and external devices, and support OPC and GPS time synchronization

Working principle and fault-tolerant mechanism
Redundant workflow: Three main processor channels independently execute control programs, synchronize data through TriBus, perform "2/3 voting" on digital input and output, and take the median of analog input to ensure that faulty channel data does not affect the final result.
Fault tolerance: When a single channel hardware fails, the other two channels automatically take over the function, and the faulty module can be replaced online without interrupting the controlled process; The power module and communication link both support redundant configuration.
Data processing: The input module microprocessor filters signals and diagnoses faults, the output module verifies output status and diagnoses wiring issues, and the main processor achieves data synchronization and error correction through TriBus.
Core functions and technical specifications
Hardware scalability
Chassis extension: up to 15, main chassis+extension chassis+remote chassis combination
I/O Capacity: Analog input/output up to 1024/512 points, digital input/output up to 2048 points, pulse input up to 80 points
Remote Expansion: Supports remote I/O connections up to 12 kilometers through RXM/SRXM modules
Communication and Interconnection
Supported protocols: Modbus (RTU/ASCII), TSAA, HART, TCP/IP, SNTP, etc
Interconnected systems: Foxboro I/A Series/Evo, Honeywell TDC-3000/UCN and other DCS
Communication speed: TriBus (4-1000 Mbps), I/O bus (375 Kbps), Ethernet (10/100 Mbps)
Diagnosis and maintenance
Diagnostic tool: EnDM software integration, real-time monitoring of hardware status, communication links, and program operation
Status indication: Each module is equipped with PASS/AULT/CTIVE indicator lights, supporting fault location
Online maintenance: The module is hot swappable and can be replaced without interrupting the on-site I/O signal
environmental adaptability
Working temperature: 0-60 ℃, storage temperature: -40-75 ℃
Humidity: 5% -95% (without condensation)
Corrosion grade: Class G3 (compliant with ISA S71.04 standard)
Vibration shock: 1 G (8.4-150 Hz), 15 G (6-11 ms)
Applicable scenarios and authentication
Typical Applications
Safety Instrumented System (SIS): Emergency Shutdown Interlock for Chemical and Petroleum Refining
Nuclear power applications: 1E level nuclear safety related controls
Marine environment: Ship automation certified by BV classification society
Other: Fire gas detection, semiconductor manufacturing safety control
Key certification
Electrical safety: CSA C22.2 No. 61010-1, UL 61010-1
Functional safety: T Ü V Rheinland IEC 61508 (SIL 1-3)
Hazardous environment: ATEX Zone 2, Class I Division 2