Storage requirements and long-term idle handling
(1) Storage Classification and Operating Standards
Storage duration operation requirements core purpose
No special treatment is required for less than one month. Tighten the fuel tank cap, turn off the battery switch, and store in a dry and ventilated place to avoid fuel evaporation and battery depletion
Add fresh gasoline and fuel stabilizer every 2-6 months, empty the carburetor float chamber, wipe the equipment surface, and cover it with a breathable dust cover to prevent fuel deterioration and carburetor blockage
Drain the fuel tank and carburetor float chamber for at least 6 months, inject 1 teaspoon of engine oil into the cylinder, pull the pull rope to the piston compression stroke, and disconnect the battery connector to avoid fuel deposition and internal corrosion
(2) Detailed steps for long-term storage
After the equipment is shut down and cooled down for 30 minutes, open the fuel tank cap, remove the fuel filter, and use a manual fuel pump to empty the remaining fuel in the tank (electric fuel pumps are prohibited).
Remove the engine service cover, locate the carburetor float chamber drain hose, connect the hose end to the container, loosen the drain screw, drain the fuel, and tighten the screw.
Remove the spark plug, inject 1 teaspoon of 10W-30 engine oil into the cylinder, slowly pull the rope several times to evenly cover the cylinder wall with engine oil, and then install the spark plug (without connecting the high-voltage wire).
Clean the dust and debris on the surface of the equipment, close all covers, store in a dry, ventilated area away from heat and fire sources, and cover with a breathable dust cover (plastic sheeting is prohibited).
Common troubleshooting and solutions
Common causes and troubleshooting steps for fault phenomena
Unable to activate battery switch OFF, insufficient fuel, wet/faulty spark plug, low oil level triggering protection. 1. Check the battery switch to ON and replenish fuel; If the low oil LED lights up, wait for 5 minutes to restart after adding engine oil; 3. Remove the spark plug, dry it and check the gap (0.60-0.80mm). If it is damaged, replace it; 4. When the battery runs out of power, start it by hand and charge the battery after starting
Immediately stop the machine after starting, if the oil level is abnormal, the fuel is contaminated, or the air filter is clogged. 1. Check the oil level, if it is insufficient, replenish it, and if it is excessive, discharge it to the standard mark; 2. Drain the deteriorated fuel and add fresh gasoline; 3. Clean or replace the air filter to ensure smooth air intake
No output power overload triggering protection, circuit breaker tripping, load fault 1. Disconnect all loads, press the "overload reset" button, and restart the equipment; 2. Check the branch circuit breaker (20A/30A) and reset it if it trips; 3. Test the load separately, troubleshoot the faulty equipment, and reconnect it
Insufficient power/shaking during operation, poor fuel quality, clogged air filter, and unsuitability for high altitude. 1. Replace with fresh gasoline and add fuel stabilizer; 2. Clean the air filter and replace it if it is severe; 3. Install high-altitude kit and adjust carburetor when altitude>2000 feet
Excessive noise/high fuel consumption ECO mode not activated, engine oil aging, spark plug carbon deposition 1. Activate ECO mode under light load; 2. Change the engine oil periodically; 3. Clean the carbon deposits on the spark plug, adjust the gap or replace it
Application scenarios and selection suggestions
(1) Core application areas
Emergency power supply for households: In the event of a power outage, it supplies power to devices such as refrigerators, air conditioners, lighting, routers, etc. to ensure basic living needs.
Outdoor camping/RV travel: Drive the RV air conditioning, induction cooker, charging equipment, and use ECO mode to reduce noise and enhance the camping experience.
Outdoor homework/small projects: providing power for electric drills, cutting machines, lighting equipment, portable design suitable for mobile scenarios such as construction sites and decoration.
Commercial backup power supply: used in small shops, convenience stores, clinics, and other places as a temporary power supply during power outages to avoid business interruptions.
(2) Key points of selection
Power matching: Based on the total power of the core load, a 20% margin should be reserved (for example, if the total load is 3000W, selecting 3900W rated power is just suitable) to avoid overload.
Scenario adaptation: Outdoor camping prioritizes portability and noise, and can be paired with ECO mode; Emergency power supply should pay attention to start-up speed and reliability, and prioritize remote control/electric start-up.
Expansion requirements: If higher power may be needed in the future, choose models that support parallel operation to avoid duplicate investments.
Maintenance convenience: Prioritize models with easy to purchase accessories and simple maintenance steps. iGen5000 original accessories can be easily obtained through the official website or authorized dealers.