Battery connection: Connect the battery quick connector to ensure a secure connection (both electric and remote start rely on the battery).
2. Start the process
Preprocessing: Turn the battery switch to "ON", the fuel selection switch to the corresponding fuel position (gasoline/propane), turn off all loads, and remote start requires pairing to be completed first (long press the pairing button on the control panel, then press the start stop button on the remote control).
Start operation:
Electric start: Press and hold the "START" button on the control panel for 2 seconds, then release it after the engine starts.
Remote control start: Press the "START" button on the remote control for 1 second, effective up to 30 meters away.
Hand pulled start: The refrigerator needs to close the air door, hold the starting rope and slowly pull it until there is resistance, then quickly pull it; After starting, gradually open the air door to the "RUN" position.
Stable operation: Run without load for 3-5 minutes to preheat, observe that the display screen parameters are normal (voltage and frequency are stable), and connect to the load after there is no abnormal noise.
3. Shutdown process
Normal shutdown: Disconnect all loads, let the generator run without load for 3-5 minutes, press the "STOP" button on the control panel or remote control, close the fuel valve (gasoline: close the tank valve; propane: close the tank valve), and finally close the battery switch.
Emergency shutdown: In case of leakage, abnormal noise, overload, etc., press the "STOP" button directly or turn off the engine switch to forcibly shut down.
Cleaning and tidying up: Disconnect fuel and power connections, clean equipment surfaces, and store hoses and cables.

Maintenance and Storage
1. Routine maintenance
Maintenance project cycle operation content
Check the oil level before each use, and if it is below the "L" mark, replenish it
Oil change for the first 25 hours/every 50 hours thereafter. After heating up, drain the oil, replace with new oil, and drain the bolt seal gasket
Air filter maintenance Check every 25 hours/Clean every 50 hours/Replace the foam filter element every 300 hours Clean it with detergent, dry it in the air and apply a small amount of engine oil; Paper filter element is blown with compressed air
Spark plug maintenance check every 100 hours/replace every 300 hours to clean carbon deposits, check gap (0.024-0.032 inches), replace if damaged
Clean the spark suppressor every 100 hours by removing the muffler cover, cleaning the carbon buildup on the filter screen, and replacing it if it is damaged
Replace the fuel filter every 100 hours, close the fuel valve, remove the old filter element, and install the new filter element in the original direction
When the battery is not used for a long time, it should be charged monthly with a matching charger to maintain sufficient power and avoid damage caused by power loss
2. Storage requirements
Short term storage (≤ 1 month): Clean the equipment, empty the residual fuel in the hose, close the fuel valve, and store in a dry and ventilated place.
Mid term storage (2-6 months): Add fresh fuel and stabilizer, empty the fuel in the carburetor float, disconnect the battery and charge it monthly.
Long term storage (>6 months):
Drain the fuel tank and carburetor, and replace with new engine oil.
Remove the spark plug, inject 1 teaspoon of engine oil into the cylinder, pull the starting rope several times (to prevent corrosion), and reinstall the spark plug.
Disconnect the battery, store it separately after fully charging, cover the generator with a dust cover, and place it in a dry and cool place.
Winter storage: After following the long-term storage process, inject RV specific antifreeze (177mL) into the water pump to prevent freezing and cracking.
Common troubleshooting
Possible causes and solutions for the fault phenomenon
Unable to start battery depletion, fuel shortage/deterioration, spark plug failure, propane leakage, incorrect throttle position for charging or battery replacement; Supplement fresh fuel; Clean/replace spark plugs; Check for propane leaks; Cold engine closes the air door, hot engine opens the air door
Immediately stop the machine after starting, low oil protection triggered, load not disconnected, fuel supply interrupted to replenish oil; Disconnect all loads; Check if the fuel valve is open and if the hose is blocked
Insufficient power/unstable speed, excessive load, clogged air filter, poor fuel supply, unadjusted high altitude, reduced load to rated range; Clean/replace the air filter; Check the fuel filter and hoses; High altitude kits need to be installed for altitudes greater than 5000 feet
No output voltage circuit breaker tripped, GFCI not reset, loose wiring, load short circuit, reset circuit breaker after overload investigation; Press the "RESET" button on the GFCI socket; Tighten the wiring; Troubleshooting equipment short circuit issues
Abnormal operation of propane mode, hose bending, fuel selection switch not in place, carburetor residual gasoline sorting hose to avoid bending; Turn the fuel switch to full position; Switch to gasoline mode, exhaust residual gasoline, and then switch back to propane
Email:wang@kongjiangauto.com