  • GE IS200JPDFG1A - DC PMD CARD
    ❤ Add to collection
  • GE IS200JPDFG1A - DC PMD CARD

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    IS200JPDFG1A - DC PMD CARD
    • ¥12000.00
      ¥24520.00
      ¥12000.00
      ¥12000.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.600KG
    • Quantity:
    • (Inventory: 33)
Description
IS200JPDFG1A - DC PMD CARD

GE IS200JPDFG1A - DC PMD CARD

Part Number IS200JPDFG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS200JPDFG1A is a Power Distribution Board developed by GE. The JPDF board accepts redundant 125 V dc power inputs and distributes power to other system boards. JPDF operates on a floating dc bus centered on Earth rather than a grounded system. This detects system ground faults and has a non-hazardous live 125 V dc rating. IS200JPDFG1A Features Input 125 V dc battery power is connected to a terminal board on the module. 

Before being connected to the board via the J1 connector, the power is routed through a 125 V dc 30 A circuit breaker and line filter. The alternating current voltage is then routed to three fused non-switched outputs and six fused switched outputs. The alternating current power is routed through the board to the DACA modules, where it is converted to direct current power. DC power is returned to JPDF and combined with the battery power input. JPDF can operate with any combination of one or more active inputs, resulting in a high-reliability 125 V dc power source for the control system. 

The JPDF module provides full status feedback via a PPDA I/O pack connection. Feedback includes detection of bus magnitude, ground faults, and excessive ac voltage on the dc bus. Each fused branch circuit is checked for the presence of output power. Installation The module is vertically mounted on a metal back base in a PDM cabinet. The JPDF sheet metal must be connected to the system's protective earth (PE). Terminals DCHI and DCLO receive input battery power. Ac power is applied to JAF1 when one or two DACA modules are used, typically from a JPDB module. JZ2 and JZ3 connectors connect DACA modules to JPDF. The system's output circuits are connected as documented. A 50-pin ribbon cable from JPDF connector P1 to the P2 connector on the board containing PPDA is required for a power distribution system with a PPDA power diagnostic I/O pack. 

Using the P2 connector, this connection can be extended to other core PDM boards. Ground Fault Detection The module supports the use of a dc bus with a high resistance that is centered on ground potential. This configuration detects a ground fault when the positive or negative bus voltages reach ground potential. It includes separate voltage feedback sensing for positive and negative power with respect to ground to support this arrangement. When the feedback is connected to a PPDA I/O pack, the system detects ground faults. 

The resistance used to center the dc bus on ground determines the sensitivity of ground detection and the ground fault currents that can flow. It has centering resistors chosen by jumper JP1. If centering resistance is provided elsewhere, the JPDF jumper should be left open. JPDF is then designed to introduce the least amount of centering resistance into the system. JP1 should be closed if JPDF is providing the centering function. Only one JPDF module should have a closed JP1 jumper if two are used. Operation Terminals DCHI and DCLO are powered by a dc battery. 

It then passes through a 30 amp dc circuit breaker and into a filter assembly located beneath the IS200JPDF circuit board. The filtered output is then routed to the JPDF circuit board via a series diode. The JAF1 connector receives alternating current power. The 115/230 V alternating current is routed to two connectors, JZ2 and JZ3, and then out to two DACA modules. The DACA modules convert alternating current to direct current (125 V dc). DC power returns to JPDF via the same JZ2 and JZ3 connectors, where it is combined with battery power if present.Module manufactured by General Electric as part of the Mark VI/VIe Series used in gas turbine sppedtronic control systems

Technical specifications and performance

Voltage & Current: Specific voltage and current specifications may vary depending on application scenarios and customised requirements, but usually have multiple voltage and frequency adaptations to suit the power standards of different regions.

Durability and Safety: High-quality power interface boards are usually made of durable materials and equipped with safety devices such as fuses and circuit breakers to ensure long term reliability and stability while protecting the equipment and users.

Communication features: Some power interface boards may have communication interfaces that allow the device to communicate with a computer or other control system for remote monitoring and control.

Indicator Lights and Displays: Some power interface boards may be equipped with indicator lights for displaying information such as power status, connection status, etc., to facilitate troubleshooting and status monitoring by users.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • OMRON CK3W-AX Multi axis Control Selection
  • Debugging and maintenance of EPSON RC90/RC90-B controller
  • Nthytronic Group iRTUe I/O Expansion Module
  • Schneider ATV320 Inverter Installation and Debugging Guide
  • Eaton SPB Drawdown Switch Maintenance Guide
  • GFS EVO-SP dual fuel retrofit complete solution
  • OMRON CJ2 CPU Troubleshooting and Maintenance
  • Complete Guide to Lenze ECS Servo System
  • GE EX2100e Excitation System Complete Guide
  • OMRON G3PW Power Controller: Parameter Setting and Troubleshooting Guide
  • Key Points for Selection and Deployment of MITSUBISHI FX3GE PLC
  • Beckhoff EP23xx EtherCAT Box Selection Troubleshooting
  • MITSUBISHI MDS-B servo troubleshooting
  • TOYO valve pressure and temperature selection
  • SIEMENS SIMODRIVE 611 HR/HRS Replacement and Advanced Positioning Techniques
  • SIEMENS SINUMERIK 840C 611-D Startup and Troubleshooting Guide
  • FANUC Series 0i-F Maintenance and Troubleshooting
  • Troubleshooting Schneider Modicon TM3 Bus Expansion
  • Troubleshooting of R&S EPL1000
  • Baum ü llerb b maXX 5000 Safety Configuration and Troubleshooting Guide
  • Huichuan AM600 Motion Controller Malfunction and Replacement Guide
  • Allen Bradley Ultra3000 Servo Motor Replacement Guide
  • NEC NL8060BC26-17 LCD Module Maintenance and Replacement
  • ABB Pluto Safety PLC Maintenance and Troubleshooting
  • OMRON NE1A Safety Controller Troubleshooting and Replacement
  • Allen Bradley 2711P series PanelView Plus human-machine interface terminal
  • NI cFP-22xx on-site integration and troubleshooting
  • KEYENCE XG-8000 Line Scan Visual Debugging Guide
  • OMRON G9SX Security Unit Configuration and Troubleshooting
  • OMRON CPM1A Maintenance and Troubleshooting
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide