Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS220PSFDH1A - IO PACK, 335V POWER SUPPLY
    ❤ Add to collection
  • GE IS220PSFDH1A - IO PACK, 335V POWER SUPPLY

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    IS220PSFDH1A - IO PACK, 335V POWER SUPPLY
    • ¥12000.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.600KG
    • Quantity:
    • (Inventory: 33)
Description
IS220PSFDH1A - IO PACK, 335V POWER SUPPLY

GE IS220PSFDH1A - IO PACK, 335V POWER SUPPLY

Part Number IS220PSFDH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS220PSFDH1A is a Flame Detector Power Supply manufactured by General Electric as part of the Mark VI Series used in gas turbine control systems. The primary gas turbine trip protection (TRPG) terminal board is normally mounted above the Flame Detector Power Supply (PSFD). 

A power distribution board provides 28 V dc as the source power (JPDL). 335 V dc, 5 mA is the output's rated rating. Up to eight flame detectors can be powered by three power supplies linked in a diode-ORed, TMR arrangement to the TRPG's J3, J4, and J5. Should the other two power supplies fail, each supply has enough power to operate all eight flame detectors. The PSFD's primary characteristics are as follows: Convectional cooling, which uses no cooling fans The ambient temperature is between -30 and 65 C (-22 to 149 oF) Input of 28 V dc 5% (26.6 to 29.4 V dc) Unregulated output varies by 5% depending on the input (318 to 352 V dc) Isolation at 1700 V DC Protection against output over-voltage A 335 V dc attenuated test point pair Output Three troubleshooting LEDs External diodes can be used to diode-OR the outputs. 

A 7 mA dc output current limit The inrush current for soft start hot swap input is capped at 550 mA. Input filtering minimizes the sensitivity to input interference and limits emissions. INSTALLATION OF FLAME DETECTOR POWER SUPPLY Install the mounting plate for the PSFD after firmly mounting the TRPG. This mounting is typically located above the TRPG on the upper level. The mounting plant must be linked to chassis ground, commonly FE, in order to reduce the risk of electrical shock (Field Earth). Using the housing's threaded studs, mechanically secure the PSFD. On the mounting plate, the studs slip into mounting brackets. Connect the PSFD 2x2 connection P2 and J3, J4, or J5 on the TRPG with the 335 V dc cable. 

Connect the 1x3 connector P1 on the side of the PSFD to supply 28 V dc power to it. This connector has an inherent soft-start feature that controls current inrush on power application, thus it is not essential to insert it with the power disconnected from the cable. OPERATION: The PSFD converts 28 V dc to 335 V dc. Current-limited and hot-swap compatible, the 28 V dc input. Transformer isolation separates the floating output from the input. A fixed ratio push-pull converter with an unregulated switching architecture is used. The input is also hot swappable, and the input and output are both current limited. 

 The 25 kHz switching power supply architecture is push-pull with no feedback or an open loop. According to the input voltage, the output rises and falls. The push-pull transformer has a 1:12 turns ratio to increase the 28 V dc input to 336 V dc. Diode drops further reduce the output voltage by 1.5 V dc, leaving 334 to 335 V dc. Because the power stage's current capacity is substantially higher than the necessary load current, the load control is still good even in this open loop design. Both overcurrent and inrush current is protected by the input circuit breaker. The breaker modulates a series pass FET on and off during current limiting to reduce power loss. If connected to a P28 V dc bus that is active, the PSFD can be hot-plugged and won't interfere with other delicate loads. 

The fast-acting circuit breaker stops a short circuit from spreading across the 28 V dc bus if a circuit failure and short circuit happen downstream of the circuit breaker. The 28 V dc bus's exposure to noise is decreased by an EMI filter. After the input connector, a 33 V transform shields the PSFD from voltage spikes and errant reverse bias connections. Even during a direct short, the output limiter limits the current to 7 mA. Even in an environment that is 65 C (149 F), the output can remain shorted indefinitely. At the output, transient protection is provided by a 385 V MOV. 

 DIAGNOSTICS: A differential pair of test points allow for the local monitoring of the output voltage. A 100:1 attenuator that is referred to as the chassis for security connects the positive and negative test points to the positive and negative outputs, respectively. There is no risk of electric shock when touching any test site. In addition, a permanent short to the chassis is possible at each test point. Both TP POS (inboard) and TP NEG are used to identify the test points (outboard). Rotating the top round plastic cover will allow you to reach the test spots. Three status LEDs are seen on the PSFD: At 6-7 mA, the Current Limit, Red, DS3 switch turns on. P335 Out, Green, DS2 - The output could have excessive voltage. 

This LED cannot reveal the exact voltage level. P28 In, Green, DS1 - The input has voltage. This LED cannot reveal the exact voltage level. The input and output LEDs only signal the existence of input or output voltage and do not represent any specific voltage level. Similar to the voltage limit LED, the current limit LED does not measure the over-current magnitude and is just intended to serve as an indication. The signal path for the activation signal and the current limit LED are connected in series. In the event that the current limit LEDs malfunction open, a circuit gets around the LED and the limiter keeps working. Each PSFD's output voltage is attenuated and detected on the TRPG terminal board. The PTUR I/O pack continuously monitors the measured voltage. An alarm is announced in the ToolboxST program or Alarm Viewer in a TMR system if any one of the three PSFDs cannot supply 335 V dc.Module manufactured by General Electric as part of the Mark VI/VIe Series used in gas turbine sppedtronic control systems

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide