Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS220PSFDH1A - IO PACK, 335V POWER SUPPLY
    ❤ Add to collection
  • GE IS220PSFDH1A - IO PACK, 335V POWER SUPPLY

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    IS220PSFDH1A - IO PACK, 335V POWER SUPPLY
    • ¥12000.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.600KG
    • Quantity:
    • (Inventory: 33)
Description
IS220PSFDH1A - IO PACK, 335V POWER SUPPLY

GE IS220PSFDH1A - IO PACK, 335V POWER SUPPLY

Part Number IS220PSFDH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS220PSFDH1A is a Flame Detector Power Supply manufactured by General Electric as part of the Mark VI Series used in gas turbine control systems. The primary gas turbine trip protection (TRPG) terminal board is normally mounted above the Flame Detector Power Supply (PSFD). 

A power distribution board provides 28 V dc as the source power (JPDL). 335 V dc, 5 mA is the output's rated rating. Up to eight flame detectors can be powered by three power supplies linked in a diode-ORed, TMR arrangement to the TRPG's J3, J4, and J5. Should the other two power supplies fail, each supply has enough power to operate all eight flame detectors. The PSFD's primary characteristics are as follows: Convectional cooling, which uses no cooling fans The ambient temperature is between -30 and 65 C (-22 to 149 oF) Input of 28 V dc 5% (26.6 to 29.4 V dc) Unregulated output varies by 5% depending on the input (318 to 352 V dc) Isolation at 1700 V DC Protection against output over-voltage A 335 V dc attenuated test point pair Output Three troubleshooting LEDs External diodes can be used to diode-OR the outputs. 

A 7 mA dc output current limit The inrush current for soft start hot swap input is capped at 550 mA. Input filtering minimizes the sensitivity to input interference and limits emissions. INSTALLATION OF FLAME DETECTOR POWER SUPPLY Install the mounting plate for the PSFD after firmly mounting the TRPG. This mounting is typically located above the TRPG on the upper level. The mounting plant must be linked to chassis ground, commonly FE, in order to reduce the risk of electrical shock (Field Earth). Using the housing's threaded studs, mechanically secure the PSFD. On the mounting plate, the studs slip into mounting brackets. Connect the PSFD 2x2 connection P2 and J3, J4, or J5 on the TRPG with the 335 V dc cable. 

Connect the 1x3 connector P1 on the side of the PSFD to supply 28 V dc power to it. This connector has an inherent soft-start feature that controls current inrush on power application, thus it is not essential to insert it with the power disconnected from the cable. OPERATION: The PSFD converts 28 V dc to 335 V dc. Current-limited and hot-swap compatible, the 28 V dc input. Transformer isolation separates the floating output from the input. A fixed ratio push-pull converter with an unregulated switching architecture is used. The input is also hot swappable, and the input and output are both current limited. 

 The 25 kHz switching power supply architecture is push-pull with no feedback or an open loop. According to the input voltage, the output rises and falls. The push-pull transformer has a 1:12 turns ratio to increase the 28 V dc input to 336 V dc. Diode drops further reduce the output voltage by 1.5 V dc, leaving 334 to 335 V dc. Because the power stage's current capacity is substantially higher than the necessary load current, the load control is still good even in this open loop design. Both overcurrent and inrush current is protected by the input circuit breaker. The breaker modulates a series pass FET on and off during current limiting to reduce power loss. If connected to a P28 V dc bus that is active, the PSFD can be hot-plugged and won't interfere with other delicate loads. 

The fast-acting circuit breaker stops a short circuit from spreading across the 28 V dc bus if a circuit failure and short circuit happen downstream of the circuit breaker. The 28 V dc bus's exposure to noise is decreased by an EMI filter. After the input connector, a 33 V transform shields the PSFD from voltage spikes and errant reverse bias connections. Even during a direct short, the output limiter limits the current to 7 mA. Even in an environment that is 65 C (149 F), the output can remain shorted indefinitely. At the output, transient protection is provided by a 385 V MOV. 

 DIAGNOSTICS: A differential pair of test points allow for the local monitoring of the output voltage. A 100:1 attenuator that is referred to as the chassis for security connects the positive and negative test points to the positive and negative outputs, respectively. There is no risk of electric shock when touching any test site. In addition, a permanent short to the chassis is possible at each test point. Both TP POS (inboard) and TP NEG are used to identify the test points (outboard). Rotating the top round plastic cover will allow you to reach the test spots. Three status LEDs are seen on the PSFD: At 6-7 mA, the Current Limit, Red, DS3 switch turns on. P335 Out, Green, DS2 - The output could have excessive voltage. 

This LED cannot reveal the exact voltage level. P28 In, Green, DS1 - The input has voltage. This LED cannot reveal the exact voltage level. The input and output LEDs only signal the existence of input or output voltage and do not represent any specific voltage level. Similar to the voltage limit LED, the current limit LED does not measure the over-current magnitude and is just intended to serve as an indication. The signal path for the activation signal and the current limit LED are connected in series. In the event that the current limit LEDs malfunction open, a circuit gets around the LED and the limiter keeps working. Each PSFD's output voltage is attenuated and detected on the TRPG terminal board. The PTUR I/O pack continuously monitors the measured voltage. An alarm is announced in the ToolboxST program or Alarm Viewer in a TMR system if any one of the three PSFDs cannot supply 335 V dc.Module manufactured by General Electric as part of the Mark VI/VIe Series used in gas turbine sppedtronic control systems

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer
  • UniOP ePAD32B/ePAD33B/ePAD33BT Industrial HMI
  • UniOP ePAD05/06 Human Computer Interface
  • UniOP ePAD03/04 Human Computer Interface
  • UniOP BKDR-46-0045 Human Machine Interface
  • UniOP BKDR-16 human-machine interface
  • Beckwith M-3425A Relay Guide
  • Basler DECS-200-2L excitation system
  • Basler DECS-250 Excitation System Debugging Guide
  • HA-800A Servo Drive Debugging Guide
  • JUMO dTRANS p35 Manual
  • KEBA XE020 RFID Module Manual
  • Honeywell SmartLine Transmitter Complete Guide
  • Eaton CROUSE-HINDS Series MA30 Lightning Protection Filter Installation Guide
  • BECKHOFF EL31xx Series 16 Bit EtherCAT Analog Input Terminal Manual
  • BECKHOFF AX5000 Servo Drive Maintenance Guide
  • BECKHOFF EL30xx Analog Input Diagnostic Guide
  • BECKHOFF EL70x7 Stepper Terminal Maintenance Guide
  • BECKHOFF CX52x0 Industrial Control Computer Maintenance Guide
  • BECKHOFF CX9000/CX9010 Hardware Maintenance Guide
  • BECKHOFF AM8xxx Motor Guide