  • GE IS200TBCIH1C Contact Input Terminal Board
    ❤ Add to collection
  • GE IS200TBCIH1C Contact Input Terminal Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS200TBCIH1C Contact Input Terminal Board

    • ¥28856.00
      ¥29985.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:4.000KG
    • Quantity:
    • (Inventory: 36)
Description

GE IS200TBCIH1C Contact Input Terminal Board


GE IS200TBCIH1C Contact Input Terminal Board

Part Number IS200TBCIH1C Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS200TBCIH1C is a Contact Input Terminal Board manufactured by General Electric as part of the Mark VI Series used in gas turbine control systems. 24 dry contact inputs are supported by the contact input terminal board, and they are wired to two barrier-type terminal blocks. To excite the contacts, TBCI is linked with dc electricity. For surge and high-frequency noise protection, noise suppression circuitry is present at the contact inputs. MARK VI SYSTEMS: The terminal board of the Mark VI system is connected to the VME rack housing the VCCC or VCRC processor board by cables with molded connections. Systems in both simplex and TMR are supported. 

The TBCIH1B and TBCIH2B boards are identical to the TBCIH1C and TBCIH2C boards in terms of functionality and are compatible with Mark VI. MARK VIe SYSTEMS: The PDIA I/O packets in the Mark VIe system plug into the TBCI. A range of system configurations is supported by one, two, or three PDIA packs. For connector JT1 to be correctly mechanically aligned with the mechanical support of the I/O pack in Mark VIe, this board must be in the C version. INSTALLATION: WIRING: The two I/O terminal blocks installed on the terminal board are directly linked to the 24 dry contact inputs. 

Two screws hold these blocks in place, and they can be unplugged from the board for upkeep. Each block has 24 terminals that can accommodate wires up to #12 AWG. Directly to the left of each terminal block is a shield terminal strip connected to the chassis ground. POWER CONNECTION: The excitation voltage is wired in through plugs JE1 and JE2. CABLING CONNECTIONS: JR1 is used for simplex systems, and all three connectors are utilized for TMR systems. Depending on the type of Mark VI or Mark VIe system and the level of redundancy, cables or I/O packs are plugged in. 

 OPERATION: Near each input's point of signal entry, filters decrease high-frequency noise and prevent surges. From a floating 125 V dc (100-145 V dc) supply from the turbine control, the dry contact inputs on H1 receive their power. Each contact input is fed after the 125 V dc bus has been current restricted in the power distribution module. The specification table indicates that the H2 and H3 variants use lower voltages. The system controller receives the discrete input voltage signals from the I/O processor, which then passes them to optical isolators for group isolation. In isolation circuits, the reference voltage establishes a transition threshold that is equal to 50% of the applied floating power supply voltage. When the voltage drops below this threshold, all contacts are required to display open, thus the tracking is clamped to go no lower than 13 percent of the nominal rated supply voltage. 

 Each input has two terminal points, one of which (a screw) serves as the positive dc source and the other of which (an input) serves as the return to the board. The first 21 inputs on each terminal board have a current loading of 2.5 mA per point, while the final three have a 10 mA loading to facilitate interfacing with external solid-state output devices. Designed for NEMA Class G creepage and clearance is the contact input circuitry. 

 DIAGNOSTICS: One is monitoring the excitation voltage. The I/O pack/board sets and latches a diagnostic warning if the excitation falls under 40% of the nominal voltage. To test the terminal board, all inputs are compelled to the open contact (fail-safe) state. Any input that does not pass the diagnostic test is put into the failsafe state, which causes a fault to be created. A fault is issued if the input from this board does not match the TMR voted value from all three boards. The I/O pack or board interrogates each terminal board connector's unique ID device. A read-only chip that also contains the board's serial number, board type, revision number, and the location of the JR1/JS1/JT1 connectors is coded with the connector ID. A hardware incompatibility fault is triggered when the controller reads the chip and a mismatch is found.

SPECIFICATIONS

Part Number: IS200TBCIH1C
SKU: IS200TBCIH1C
Manufacturer: General Electric
Series: Mark VI
Product Type: Terminal Board
Number of Channels: 24 contact voltage input channels
Input Current: 125 V dc
Power Consumption: 20.6watts
Operating Temperature: -30 to 65oC
Availability: In Stock
Country/Region of Manufacture: United States
Repair: 3-7 Days
Manual: GEH-6421J


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Renesas ICL232 Transceiver Application Guide
  • Rexroth VT-VRPA2 Valve Amplifier Debugging Guide
  • Rexroth IndraDrive C HCS Debugging Guide
  • Rexroth IndraControl L25 Controller Selection Guide
  • Rexroth Indramat BTV20.3 Operation Terminal Installation and Maintenance Guide
  • Bosch Rexroth Indramat PPC-R02 Controller Replacement Guide
  • Phoenix Contact Inline I/O System Selection Guide
  • Rexroth VCP 08 Operating Terminal Selection and Installation Guide
  • Rexroth IndraDyn H Spindle Motor Planning Guide
  • Detailed explanation of ElectroLogIXS VLC interlocking signal controller
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide