Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS200TBCIH2C Conduction Sensor board
    ❤ Add to collection
  • GE IS200TBCIH2C Conduction Sensor board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    IS200TBCIH2C
    • ¥23650.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:4.900KG
    • Quantity:
    • (Inventory: 35)
Description
IS200TBCIH2C

GE IS200TBCIH2C Conduction Sensor board

Part Number IS200TBCIH2C Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS200TBCIH2C is a Contact Input Group Isolation terminal board developed by GE. 24 dry contact inputs are wired to two barrier-type terminal blocks on the Contact Input with Group Isolation (TBCI) terminal board. For contact excitation, TBCI is coupled with DC power. Surge and high-frequency noise are protected by noise reduction circuitry in the contact inputs. TBCI supports simplex and TMR applications and works with VTCC/VCRC. 

TBCI is connected to the VME rack where the VCCC or VCRC processor board is placed by cables with molded plugs. Both the TBCIH B and TBCIH C variants of the board work with Mark VI and are functionally equivalent. The nominal voltage is 24 V dc. IS200TBCIH2C Installation Wiring Connect the wires for the 24 dry contact inputs to the terminal board's two I/O terminal blocks directly. Two screws hold these blocks in place, and they can be unplugged from the board for maintenance. Each block has 24 terminals that can accommodate wires up to #12 AWG. To the left of each terminal block is a shield terminal strip that is connected to the chassis ground. Power Connection Use plugs JE1 and JE2 to connect TBCI to the contact excitation voltage source. Cabling Connections Connect TBCI to the I/O processor using connector JR1 in a simplex system. 

Connect TBCI to the I/O processors in the TMR system using connectors JR1, JS1, and JT1. Depending on the type of Mark VI, Mark VIe, or Mark VIeS system and the level of redundancy, cables or I/O packs are plugged in. IS200TBCIH2C Operation On each input near the point of signal entry, filters decrease high-frequency noise and control surge. The dry contact inputs on H1 are powered by the turbine control's floating 125 V dc (100-145 V dc) supply. Prior to supplying each contact input, the 125 V dc bus is current limited in the power distribution module. As seen in the specification table, the H2 and H3 variants employ lower voltages. Diagnostics The following diagnostic tests are performed on components on terminal boards: The voltage of excitation is measured. The I/O pack/board sets and latches a diagnostic warning if the excitation falls below 40% of the nominal voltage. As a test, all of the terminal board's inputs are set to the open contact (fail safe) condition. 

Any input that fails the diagnostic test is forced into the failsafe mode, resulting in the creation of a fault.. A fault is issued if the input from this board does not match the TMR voted value from all three boards.. Each terminal board connector has its own ID device, which the I/O pack/board queries.. IS200TBCIH2C Specifications Number of channels 24 contact voltage input channels Input filter 4 ms Hardware filter Power consumption On the terminal board, 20.6 W Configuration On the board, there are no jumpers or hardware settings.

IS200TBCIH2C Installation

Wiring

Connect the wires for the 24 dry contact inputs to the terminal board's two I/O terminal blocks directly. Two screws hold these blocks in place, and they can be unplugged from the board for maintenance. Each block has 24 terminals that can accommodate wires up to #12 AWG. To the left of each terminal block is a shield terminal strip that is connected to the chassis ground.

Power Connection

Use plugs JE1 and JE2 to connect TBCI to the contact excitation voltage source.

Cabling Connections

Connect TBCI to the I/O processor using connector JR1 in a simplex system. Connect TBCI to the I/O processors in the TMR system using connectors JR1, JS1, and JT1. Depending on the type of Mark VI, Mark VIe, or Mark VIeS system and the level of redundancy, cables or I/O packs are plugged in.

IS200TBCIH2C Operation

On each input near the point of signal entry, filters decrease high-frequency noise and control surge. The dry contact inputs on H1 are powered by the turbine control's floating 125 V dc (100-145 V dc) supply. Prior to supplying each contact input, the 125 V dc bus is current limited in the power distribution module. As seen in the specification table, the H2 and H3 variants employ lower voltages.

Diagnostics

The following diagnostic tests are performed on components on terminal boards:

The voltage of excitation is measured. The I/O pack/board sets and latches a diagnostic warning if the excitation falls below 40% of the nominal voltage.

As a test, all of the terminal board's inputs are set to the open contact (fail safe) condition. Any input that fails the diagnostic test is forced into the failsafe mode, resulting in the creation of a fault.

A fault is issued if the input from this board does not match the TMR voted value from all three boards.

Each terminal board connector has its own ID device, which the I/O pack/board queries.

IS200TBCIH2C Specifications

Number of channels

24 contact voltage input channels

Input filter

4 ms Hardware filter

Power consumption

On the terminal board, 20.6 W


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Rexroth Indramat BTV20.3 Operation Terminal Installation and Maintenance Guide
  • Bosch Rexroth Indramat PPC-R02 Controller Replacement Guide
  • Phoenix Contact Inline I/O System Selection Guide
  • Rexroth VCP 08 Operating Terminal Selection and Installation Guide
  • Rexroth IndraDyn H Spindle Motor Planning Guide
  • Detailed explanation of ElectroLogIXS VLC interlocking signal controller
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection