Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS200TBCIH2C Conduction Sensor board
    ❤ Add to collection
  • GE IS200TBCIH2C Conduction Sensor board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    IS200TBCIH2C
    • ¥23650.00
      ¥24520.00
      ¥23650.00
      ¥23650.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:4.900KG
    • Quantity:
    • (Inventory: 35)
Description
IS200TBCIH2C

GE IS200TBCIH2C Conduction Sensor board

Part Number IS200TBCIH2C Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS200TBCIH2C is a Contact Input Group Isolation terminal board developed by GE. 24 dry contact inputs are wired to two barrier-type terminal blocks on the Contact Input with Group Isolation (TBCI) terminal board. For contact excitation, TBCI is coupled with DC power. Surge and high-frequency noise are protected by noise reduction circuitry in the contact inputs. TBCI supports simplex and TMR applications and works with VTCC/VCRC. 

TBCI is connected to the VME rack where the VCCC or VCRC processor board is placed by cables with molded plugs. Both the TBCIH B and TBCIH C variants of the board work with Mark VI and are functionally equivalent. The nominal voltage is 24 V dc. IS200TBCIH2C Installation Wiring Connect the wires for the 24 dry contact inputs to the terminal board's two I/O terminal blocks directly. Two screws hold these blocks in place, and they can be unplugged from the board for maintenance. Each block has 24 terminals that can accommodate wires up to #12 AWG. To the left of each terminal block is a shield terminal strip that is connected to the chassis ground. Power Connection Use plugs JE1 and JE2 to connect TBCI to the contact excitation voltage source. Cabling Connections Connect TBCI to the I/O processor using connector JR1 in a simplex system. 

Connect TBCI to the I/O processors in the TMR system using connectors JR1, JS1, and JT1. Depending on the type of Mark VI, Mark VIe, or Mark VIeS system and the level of redundancy, cables or I/O packs are plugged in. IS200TBCIH2C Operation On each input near the point of signal entry, filters decrease high-frequency noise and control surge. The dry contact inputs on H1 are powered by the turbine control's floating 125 V dc (100-145 V dc) supply. Prior to supplying each contact input, the 125 V dc bus is current limited in the power distribution module. As seen in the specification table, the H2 and H3 variants employ lower voltages. Diagnostics The following diagnostic tests are performed on components on terminal boards: The voltage of excitation is measured. The I/O pack/board sets and latches a diagnostic warning if the excitation falls below 40% of the nominal voltage. As a test, all of the terminal board's inputs are set to the open contact (fail safe) condition. 

Any input that fails the diagnostic test is forced into the failsafe mode, resulting in the creation of a fault.. A fault is issued if the input from this board does not match the TMR voted value from all three boards.. Each terminal board connector has its own ID device, which the I/O pack/board queries.. IS200TBCIH2C Specifications Number of channels 24 contact voltage input channels Input filter 4 ms Hardware filter Power consumption On the terminal board, 20.6 W Configuration On the board, there are no jumpers or hardware settings.

IS200TBCIH2C Installation

Wiring

Connect the wires for the 24 dry contact inputs to the terminal board's two I/O terminal blocks directly. Two screws hold these blocks in place, and they can be unplugged from the board for maintenance. Each block has 24 terminals that can accommodate wires up to #12 AWG. To the left of each terminal block is a shield terminal strip that is connected to the chassis ground.

Power Connection

Use plugs JE1 and JE2 to connect TBCI to the contact excitation voltage source.

Cabling Connections

Connect TBCI to the I/O processor using connector JR1 in a simplex system. Connect TBCI to the I/O processors in the TMR system using connectors JR1, JS1, and JT1. Depending on the type of Mark VI, Mark VIe, or Mark VIeS system and the level of redundancy, cables or I/O packs are plugged in.

IS200TBCIH2C Operation

On each input near the point of signal entry, filters decrease high-frequency noise and control surge. The dry contact inputs on H1 are powered by the turbine control's floating 125 V dc (100-145 V dc) supply. Prior to supplying each contact input, the 125 V dc bus is current limited in the power distribution module. As seen in the specification table, the H2 and H3 variants employ lower voltages.

Diagnostics

The following diagnostic tests are performed on components on terminal boards:

The voltage of excitation is measured. The I/O pack/board sets and latches a diagnostic warning if the excitation falls below 40% of the nominal voltage.

As a test, all of the terminal board's inputs are set to the open contact (fail safe) condition. Any input that fails the diagnostic test is forced into the failsafe mode, resulting in the creation of a fault.

A fault is issued if the input from this board does not match the TMR voted value from all three boards.

Each terminal board connector has its own ID device, which the I/O pack/board queries.

IS200TBCIH2C Specifications

Number of channels

24 contact voltage input channels

Input filter

4 ms Hardware filter

Power consumption

On the terminal board, 20.6 W


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice