  • GE IS2020LVPSG2A Low Voltage Power Supply Module
    ❤ Add to collection
  • GE IS2020LVPSG2A Low Voltage Power Supply Module

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS2020LVPSG2A Low Voltage Power Supply Module

    • ¥9254.25
      ¥10385.25
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:10.000KG
    • Quantity:
    • (Inventory: 54)
Description

GE IS2020LVPSG2A Low Voltage Power Supply Module


GE IS2020LVPSG2A Low Voltage Power Supply Module

Part Number IS2020LVPSG2A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS2020LVPSG2A is a Power Supply Board developed by GE. It is a part of Mark VI control system. The power supply is equipped with a single user control, which is the power switch, along with three status LED indicators. The power switch, situated on the front panel, allows users to control the output voltages of the power supply. Additionally, when toggled, it serves as a fault reset mechanism. 

The LED indicators come in yellow, red, and green, providing information on the status of input power, the presence of faults, and normal operation, respectively. Features Input Voltage: The power supply operates with a direct current (DC) input voltage of 24 volts. Output Rating: It delivers a total power output of 400 watts, ensuring power supply for various components within the system. +28V PSA Outputs (Quantity: 5): The power supply features five outputs delivering a regulated voltage of +28 volts DC. 

These outputs are designed to supply power to specific sections or modules within the system, ensuring reliable and consistent power distribution. +28V Remote Outputs (Quantity: 1): In addition to the PSA outputs, there is one remote output delivering a regulated voltage of +28 volts DC. This output can be utilized for powering external devices or components, offering flexibility in system configuration and expansion. PS335 Output: The power supply does not include an output for a voltage rating of 335 volts DC. Status ID Output: The power supply is equipped with a status identification (ID) output, providing feedback or signaling regarding the operational status of the unit. This feature enhances monitoring capabilities and facilitates timely maintenance or troubleshooting. 

Support Redundant Operation: The power supply is designed to support redundant operation, meaning it is capable of seamlessly switching to a backup power source in case of failure or malfunction. This ensures continuity of power supply and minimizes downtime, critical for systems requiring high reliability and availability. Installation Mounting: The power supply is affixed to the right-hand side of the VME rack using a sheet metal bracket. Connection Points: The power supply features various connection points: DC Inputs and Outputs: These are located at the bottom of the power supply and include inputs for 28 V DC and outputs for both 28 V DC and 335 V DC. Status Connector: In newer designs, there's a status connector situated at the bottom, providing additional monitoring capabilities. 

PSA and PSB Connectors: These connectors, positioned at the top of the assembly, interface with a cable harness responsible for delivering power to the VME rack. Power Distribution: The power supply comprises five 28 V DC power modules, each dedicated to supplying a specific section of the VME rack, identified as sections A, B, C, D, E, and F. Peripheral Power Option: The P28C output, also known as PS28, located at the bottom of the power supply, can serve to power an external peripheral device. To enable this functionality, the jumper plug, located on the left side of the rack, must be repositioned from its default "Normal" setting to the "Isolated" position below. Fan Configuration: The fan within the system is only operational when the controller is mounted within the rack. It receives power from the top connector on the bracket, situated on the left side of the rack. This ensures efficient cooling and system performance, particularly during operational use.

SPECIFICATIONS:

Part Number: IS2020LVPSG2A
Manufacturer: General Electric
Series: Mark VIe
Function: Low Voltage Power Supply Module
Input voltage: 230V AC
Output voltage: 2.5-7.5V, current up to 4A
Output voltage noise: < 5 mV RMS
Dimension: 261mm x 295mm x 50.8mm
Weight: 2.95 kg
Repair: 3-5 Days
Availability: In Stock
Country of Manufacture: United States (USA)
Manual: GEH-6421M

Product Benefits

Flexible Configuration:

Supports a variety of configuration options, which can be configured to different input or output modes according to specific application requirements to meet different control needs.

High performance:

Featuring fast response and high accuracy, it can monitor and control digital signals in real time to ensure the stability and reliability of the system.

Equipped with an on-board 100Mbit/s Ethernet connection, communication between the controller, operator station and engineering workstation is faster and more reliable.

Modular design:

Adopting modular design, it is easy to install, maintain and expand, and can flexibly cope with control systems of different scale and complexity.

Communication interface:

Support common communication interfaces, such as Profibus, Modbus, etc., which can exchange data and communicate with other devices and systems.

Reliable and stable:

As a well-known brand of industrial automation, ABB's products have excellent quality and stability, ensuring stable operation of the equipment for a long time.

Memory & Security:

With 10MB of memory, of which 2MB is for battery backup, to ensure the safety of data and stable operation of the system.

Provides a key lock function to prevent unauthorised downloading of applications and firmware by locking the controller, enhancing the security of the system.

Compact Front Panel Display:

Equipped with a small front panel display that visually shows status and diagnostic information for easy monitoring and maintenance of the unit.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ADLINK NuPRO-E320 motherboard deployment and tuning guide
  • ADLINK NuPRO-800 Dual PIII Industrial SBC Maintenance and Upgrade Guide
  • ADLINK NuPRO-598 SBC Maintenance Practical Guide
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK Express-BASE7 Carrier Board Quick Deployment and Debugging Guide
  • ADLINK DLAP-211 Edge AI Platform Selection and Deployment Guide
  • ADLINK 7230 Series Isolation DIO Card Selection and Engineering Application Guide
  • ADLINK cPCI-6965 SBC Embedded Installation and BIOS Tuning Guide
  • ADLINK 7200 Series High Speed DIO Card Practical Guide
  • ADLINK DLAP Series Edge AI Acceleration Platform Selection and Deployment Practical Guide
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer