Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS220PPROH1A  IO CARD MKVIE
    ❤ Add to collection
  • GE IS220PPROH1A IO CARD MKVIE

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS220PPROH1A  IO CARD MKVIE

    • ¥19358.20
      ¥19254.25
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:5.100KG
    • Quantity:
    • (Inventory: 51)
Description

GE IS220PPROH1A  IO CARD MKVIE


GE IS220PPROH1A  IO CARD MKVIE

Part Number IS220PPROH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS220PPROH1A is a Backup Turbine Protection (PPRO) I/O pack developed by GE. The Backup Turbine Protection (PPRO) I/O pack and associated terminal boards offer an independent backup Overspeed protection system, as well as a backup check for generator synchronization to a utility bus. 

They also serve as an independent watchdog for the primary control. Three triple modular redundant (TMR) PPRO I/O packs mounted to separate simplex protection (SPRO) terminal board or three PPROs put on a TMR TPROH#C terminal board constitute a typical protection system. Each SPRO or TPROH#C is connected to the designated emergency trip board through a cable with DC-37 pin connections on both ends: TREG stands for Gas Turbine Emergency Trip Terminal Board. 

TREL: Terminal Board for Large Steam Turbine Emergency Trips TRES: Terminal Board for Small/Medium Steam Turbine Emergency Trips A different configuration places three PPRO I/O packs directly on TREA for a single-board TMR protection system. For IONet communications with the control modules, the PPRO includes an Ethernet connection. Functional Description Two Ethernet ports, a power supply, a local processor, and a data acquisition board are included in the I/O pack. This design simplifies or eliminates much of the previously required instrumentation for connecting to field equipment, as well as improving operational reliability and lowering long-term maintenance costs. 

The IS220PPROH1A is utilized in Aeroderivative Turbine Emergency Trip applications and is commonly used with the TREAH terminal board. The component can be connected to terminal blocks that are either barrier or box type. For voltage sensing, the part has field-wiring restrictions that limit cable length to 1,000 feet of 18 AWG wiring. When switching from a BPPB P-Pack to a BPPC P-Pack, the component cannot be auto-reconfigured. The front faceplate of the part is marked with the component id number and many LED indications. These are arranged in pairs on the front faceplate. PWR/ATTN is the first pair, LINK/TxRx and ENET 1 is the second, and LINK/TxRx and ENET2 is the third. The final component is the IR port, which is placed at the bottom of the faceplate. The part is equipped with a high-speed processor and two 10/100 Ethernet ports that are completely independent. 

A hardware reset circuit and a watchdog timer are included in the pack. An inbuilt sensor keeps track of the temperature. Compatibility The PPRO I/O pack comprises one of the compatible BPPx processor boards listed below: The PPROH1A is equipped with a BPPB processor board. The PPROS1B includes a functionally compatible BPPC processor board that is compatible with the ControlST software suite V04.07 and later. Simplex Main Control The Mark VIe control trip board TRES supports simplex backup protection. The controller IONet has one PPRO network port.

 All Mark VIe control backup trip boards, TREG, TREL, TREA, and TRES, feature TMR backup protection. Each I/O pack is connected to a distinct (R,S,T) controller network in this setup. Triple Main Control When using a TMR main control, backup protection is supported (two out of three running). This setup is supported by all Mark VIe control backup trip boards (TREG, TREL, TREA, and TRES). The first PPRO I/O pack is connected to the R network, the second PPRO to the S network, and the third PPRO to the T network in the standard network configuration.

Functional Description

Two Ethernet ports, a power supply, a local processor, and a data acquisition board are included in the I/O pack. This design simplifies or eliminates much of the previously required instrumentation for connecting to field equipment, as well as improving operational reliability and lowering long-term maintenance costs.

The IS220PPROH1A is utilized in Aeroderivative Turbine Emergency Trip applications and is commonly used with the TREAH terminal board. The component can be connected to terminal blocks that are either barrier or box type. For voltage sensing, the part has field-wiring restrictions that limit cable length to 1,000 feet of 18 AWG wiring. When switching from a BPPB P-Pack to a BPPC P-Pack, the component cannot be auto-reconfigured.

The front faceplate of the part is marked with the component id number and many LED indications. These are arranged in pairs on the front faceplate. PWR/ATTN is the first pair, LINK/TxRx and ENET 1 is the second, and LINK/TxRx and ENET2 is the third. The final component is the IR port, which is placed at the bottom of the faceplate.

The part is equipped with a high-speed processor and two 10/100 Ethernet ports that are completely independent. A hardware reset circuit and a watchdog timer are included in the pack. An inbuilt sensor keeps track of the temperature.

Compatibility

The PPRO I/O pack comprises one of the compatible BPPx processor boards listed below:

The PPROH1A is equipped with a BPPB processor board.

The PPROS1B includes a functionally compatible BPPC processor board that is compatible with the ControlST software suite V04.07 and later.

Simplex Main Control

The Mark VIe control trip board TRES supports simplex backup protection.

The controller IONet has one PPRO network port.

All Mark VIe control backup trip boards, TREG, TREL, TREA, and TRES, feature TMR backup protection. Each I/O pack is connected to a distinct (R,S,T) controller network in this setup.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ADLINK NuPRO-E320 motherboard deployment and tuning guide
  • ADLINK NuPRO-800 Dual PIII Industrial SBC Maintenance and Upgrade Guide
  • ADLINK NuPRO-598 SBC Maintenance Practical Guide
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK Express-BASE7 Carrier Board Quick Deployment and Debugging Guide
  • ADLINK DLAP-211 Edge AI Platform Selection and Deployment Guide
  • ADLINK 7230 Series Isolation DIO Card Selection and Engineering Application Guide
  • ADLINK cPCI-6965 SBC Embedded Installation and BIOS Tuning Guide
  • ADLINK 7200 Series High Speed DIO Card Practical Guide
  • ADLINK DLAP Series Edge AI Acceleration Platform Selection and Deployment Practical Guide
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer