Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS220PPRFH1B PROFIBUS Master Gateway I/O Module
    ❤ Add to collection
  • GE IS220PPRFH1B PROFIBUS Master Gateway I/O Module

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS220PPRFH1B PROFIBUS Master Gateway I/O Module

    • ¥23698.50
      ¥23257.20
      ¥23698.50
      ¥23698.50
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:5.200KG
    • Quantity:
    • (Inventory: 53)
Description

GE IS220PPRFH1B PROFIBUS Master Gateway I/O Module


GE IS220PPRFH1B PROFIBUS Master Gateway I/O Module

Part Number IS220PPRFH1B Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS220PPRFH1B is a PROFIBUS Master Gateway I/O Module developed by GE under Mark VIe series. It is a PROFIBUS DPV0, Class 1 master that maps Mark VIe controllers on the I/O Ethernet to I/O from PROFIBUS slave devices. The module includes a processor board that is shared by all Mark VIe distributed I/O modules and an acquisition carrier board that is equipped with a Hilscher GmbH-provided COM-C PROFIBUS communication module. 

 IS220PPRFH1B Features A PROFIBUS RS-485 interface is provided by the COM-C module through a DE-9 D-sub receptacle connector. It functions as a PROFIBUS DP master, supporting up to 125 slaves with 244 bytes of inputs and outputs each with transmission rates ranging from 9.6 KBaud to 12 MBaud. The following redundancy options are supported by the PPRF: A single I/O Ethernet connection for a single I/O pack (no redundancy) A single I/O pack with two Ethernet connections for the I/Os Hot-backup Ethernet connections with two ports Other IO packs share the twin I/O Ethernet connection design. 

However, two PPRFs are used in the hot-backup system, one of which is active and connecting with slave devices via PROFIBUS and the other of which is passive and in standby mode, ready to take over in the case of an active master failure. Compatibility The PPRF is mounted on the PROFIBUS Master Gateway Terminal board (SPIDG1A), which also provides an electronic ID. As the PROFIBUS connection is connected to the DE-9 D-sub receptacle connector exposed on the side of the PPRF, the interface to the PPRF is the sole connection it has. Indicator LEDs on the PPRF give visual diagnostics. The number of I/O packs utilized in a signal path is referred to as the control mode: One I/O pack and one or two network connections are used by Simplex. 

Two I/O packs with two network connections each are used in hot-backup. IS220PPRFH1B Operation Processor The I/O pack or module function-specific acquisition board is connected to the processor board. The soft-start circuit ramps up the voltage available on the processor board when input power is applied. The processor reset is turned off and the local power supply are turned on in order. After finishing self-test routines, the processor loads application code from flash memory that is particular to the I/O pack or module type. To verify that the application code, acquisition board, and terminal board are correctly matched, the application code reads the board ID information. PROFIBUS Gateway Hardware The PROFIBUS DP (Decentralized Periphery) feature is implemented by firmware in the PPRFs COM-C module, which is based on Siemens ASPC2 technology. 

The PPRF only offers the fundamental DPV0 capability, which includes configuring slave devices, cyclically exchanging I/O data with them, and receiving PROFIBUS diagnostics, despite the fact that the COM-C module is DPV1 capable. Data Flow between PPRF and Controller Fixed I/O and PROFIBUS I/O are the two types of data flow that go between the PPRF and the controller. The few inputs and outputs that are fixed include those that are shared by all I/O packs, including L3DIAG and IOPackTmpr, but there are no application-driven outputs. The PPRF firmware contains a predefined set of fixed I/O. According to the hardware configuration supplied by the application, PROFIBUS I/O is defined as the data exchanged between PROFIBUS slave devices.

IS220PPRFH1B Features

A PROFIBUS RS-485 interface is provided by the COM-C module through a DE-9 D-sub receptacle connector. It functions as a PROFIBUS DP master, supporting up to 125 slaves with 244 bytes of inputs and outputs each with transmission rates ranging from 9.6 KBaud to 12 MBaud.

The following redundancy options are supported by the PPRF:

A single I/O Ethernet connection for a single I/O pack (no redundancy)

A single I/O pack with two Ethernet connections for the I/Os

Hot-backup Ethernet connections with two ports

Other IO packs share the twin I/O Ethernet connection design. However, two PPRFs are used in the hot-backup system, one of which is active and connecting with slave devices via PROFIBUS and the other of which is passive and in standby mode, ready to take over in the case of an active master failure.

Compatibility

The PPRF is mounted on the PROFIBUS Master Gateway Terminal board (SPIDG1A), which also provides an electronic ID. As the PROFIBUS connection is connected to the DE-9 D-sub receptacle connector exposed on the side of the PPRF, the interface to the PPRF is the sole connection it has. Indicator LEDs on the PPRF give visual diagnostics. The number of I/O packs utilized in a signal path is referred to as the control mode:

One I/O pack and one or two network connections are used by Simplex.

Two I/O packs with two network connections each are used in hot-backup.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Megatiker M4 Circuit Breaker Maintenance
  • OMRON ZX laser sensor maintenance
  • Saia PCD1 Controller Maintenance Guide
  • OMRON NT Series HMI Replacement and Maintenance
  • Yaskawa F7 Driver Maintenance and Replacement
  • Rockwell 1494 switch selection replacement
  • Omron NA Series HMI Connection Guide
  • Eaton CV Series PLC System Upgrade and Diagnosis
  • Eaton XV-102 HMI Installation and Troubleshooting
  • Siemens SINUMERIK measurement cycle configuration
  • ELAU PacDrive C600 Controller Integration Guide
  • ELAU PacDrive SM Servo Motor Application and Maintenance Guide
  • Bently Nevada Orbit 60 System Upgrade and Troubleshooting Guide
  • YOKOGAWA STARDOM FCN-RTU Controller
  • Fireye InSight II Marine Flame Scanner
  • How to install ABB VSC vacuum contactor?
  • Rexroth Bosch Group VT2000 Proportional Amplifier
  • ALSTOM ALSPA series frequency converter
  • ABB SPACOM replaces REX615
  • Meggitt C327895 Gas Metering Valve Technology
  • Application of MOOG G77x servo valve
  • WOODWARD 2301E Digital Speed Controller
  • ABB UNITOL 1010/1020 AVR Compact IGBT Automatic Voltage Regulator
  • ABB UNITOL 6000 excitation system
  • Rexroth Bosch Group HNC100 Hydraulic Shaft Control
  • Lenze 8400 Inverter Debugging Guide
  • Panning Vacuum Sensor Maintenance Guide
  • SOGEVAC Rotary Disc Pump Maintenance Guide
  • THERMOVAC MEMS Vacuum Gauge Guide
  • TTR 101 Vacuum Gauge Troubleshooting Guide
  • Honeywell Beam Smoke Detector Guide
  • TURBOVAC Molecular Pump Maintenance Guide
  • Troubleshooting of Leuze electronic DDLS 200 optical transmission
  • Lam Harmonic Drive Quick Replacement Guide
  • LZS power replacement and troubleshooting
  • MTL2000 series isolation barrier
  • Temposonics GB Sensor
  • Temposonics R Series Magnetostrictive Displacement Sensor Depth
  • Original inventor of M ü ller Co ax AG coaxial valve
  • Murrelektronik Automation Solution Complete Solution
  • Nabtesco RV series high-precision gearbox
  • NACHI Robot Full Series
  • Electro hydraulic proportional directional flow valve
  • NEC FC-9801X Industrial Computer
  • Mark VIeS Security System
  • NI RIO Platform: Embedded Measurement and Control Solution Integrating Real time Processing and FPGA
  • NI sbRIO-9612 Single Board Controller
  • NI EPM high-performance DAQ cable
  • NI SCXI-1349 Adapter Connection Guide
  • NI SCXI Chassis Configuration and Installation Guide
  • SNAP PAC System Architecture and Selection Guide
  • PacSci Model 6410 Microstep Driver
  • TI 11kW GaN three-phase ANPC inverter
  • Pepperl+Fuchs K-System Isolation Barrier Complete Guide
  • Pacific Scientific POWERMAX II stepper motor
  • LINAK LA23 Compact Industrial Electric Push Rod
  • Pacific Scientific Servo Drive Selection Guide
  • Pacific Scientific SCE900 Servo Drive Complete Guide
  • Pro face PFXSTM6400WAD human-machine interface
  • Pacific Scientific 6410 Stepper Driver
  • Parker EVM32-II Modular Expansion Base Plate
  • Parker COMPAX series compact servo controller: integrated motion control and drive
  • Parker Compumotor ZETA6000 Single Axis Drive Controller
  • PI C-663.12 Mercury Step Motor Controller
  • NetTest TUNICS series tunable external cavity laser
  • Complete Guide to Inline Automation Terminal System
  • Phoenix FL MC 1000 SC (ST) Fiber Optic Converter
  • Phoenix ST series spring cage terminal block
  • ROSS Pneumatic Valve Full Series
  • BD SENSORS DMP 333 High Pressure Transmitter
  • OE Max Controls NX70 series PLC
  • SAIA PCD4.W500/W600 Intelligent Simulation Module
  • Saia Burgess PCD4.U100 Migration Kit
  • SAIA PCD1 Controller Full Series
  • SAIA Burgess PCD2.H110 Counting and Measurement Module
  • SAMSON Type 3434 Pneumatic Controller Module
  • SanDisk iNAND Flash and microSD
  • Optimus® Product Family of SAS SSDs
  • SANMOTION PB servo stepper
  • ADCA AVM/AVF234S electric actuator
  • SBS Technologies VIPC616 Carrier Board
  • SBS Technologies VIPC616 VME Carrier Board
  • Greenspring P2 Video Graphics Controller
  • ABB UniPack-S Steel Compact Substation
  • Schaffner Ecosine ® Economy Line FS 42842 Compact Passive Harmonic Filter
  • Schenck Process INTECONT Tersus Weighing Instrument
  • ENTRELEC contactor relay
  • Smiths Connectors MHD/MDD/MDP CONNECTOR SERIES PCB High Density Connectors
  • SEW EURODRIVE DFP21B bus interface
  • SEW-EURODRIVE MOVIDRIVE B Series Manual
  • SEW Eurodrive R series parallel axis reduction motor
  • SEW EURODRIVE DFY/DFS Synchronous Motor Guide
  • SEW MOVITRAC 31C Installation and Debugging
  • SEW EURODRIVE MOVIDYN communication interface
  • SEW MOVIDRIVE UL compliant installation
  • SEW MOVIDRIVE bus positioning
  • SEW MOVIDYN ® Series servo controller
  • SEW MOVIDRIVE MD60A Inverter Guide
  • BTicino Megatiker M5 electronic circuit breaker
  • BTicino Megatiker M4 Circuit Breaker
  • BTicino Megatiker M3 160 Circuit Breaker
  • BTICINO MEGATIKER Circuit Breaker Series
  • Elmex Industrial Automation Control Products
  • Danfoss VLT ® Series 3000 series adjustable frequency drive
  • Rockwell Automation SLC 500 Series Programmable Logic Controller
  • YOKOGAWA CENTUM CS 3000 Integrated Production Control System
  • OMRON SYSMAC CS Series CS1G/H-CPU  H Programmable Controller
  • MEGGITT TQ TQ 422/432 Eddy Current Measurement System
  • MEGGITT VM600 machinery protection system (MPS)
  • IbaDeskline SAS Industrial Computer
  • IbaDAQ-C independent data acquisition device
  • IbaFOB io ExpressCard fiber optic interface card
  • IbaPADU-S-IT-16 modular central unit
  • YASKAWA ∑ - II Series SGMBH/SGDH AC Servo System
  • IbaBM CAN CAN/CANopen bus sniffer
  • IbaLink-SM-128V-i-2O VMEbus interface board
  • GE Fanuc Series 90-30 PLC Hardware System
  • Automation Direct GS2 Series Frequency Inverter Specifications and Selection
  • OMRON SYSDRIVE 3G3MV Multi-functional Compact Frequency Inverter In-depth Technical Guide
  • Danfoss VACON NXI High Power Frequency Inverter Operation Manual
  • Saia PCD4.U100 Kit System Upgrade Guide
  • Yaskawa Sigma II Series NS300 DeviceNet Application Module Deep Technical Guide
  • OMRON SSS Software C-series PLC Operating Instructions
  • Kollmorgen SERVOSTAR S Digital Servo Drive Guide: From Installation to Mastery
  • Omron C200HX/HG/HE PLC Installation Guide
  • SIEMENS SINAMICS S120 Servo Drive System Application Guide
  • Emerson ControlWave Micro Hybrid Controller
  • ABB 800xA with Advant Master integrated configuration