Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • LUST LTI DRIVES VF1204S Frequency Inverter
    ❤ Add to collection
  • LUST LTI DRIVES VF1204S Frequency Inverter

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥21537.00
      ¥22315.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.730KG
    • Quantity:
    • (Inventory: 53)
Description
<span style="font-size: 18px; font-family: arial;">LUST LTI DRIVES VF1204S Frequency Inverter</span>

LUST LTI DRIVES VF1204S G10 FA Frequency Inverter

The LUST LTI DRIVES VF1204S is a frequency inverter designed for industrial motor control. It is rated at 0.75 kW and operates from a 230 V AC supply. The G10 and FA designations define specific hardware and interface options. The inverter converts the supply into a controlled three phase output so that the speed of an AC motor can be adjusted to match process requirements. It is intended for pumps, fans, conveyors, and general machinery.

Series and Model Identification

The VF1204S belongs to the LUST LTI DRIVES frequency inverter range. The model designation identifies the power class and hardware platform. The G10 suffix describes the hardware revision and option set. The FA designation may refer to a specific filter or interface variant. The 0.75 kW rating defines the motor power the inverter can supply continuously under specified conditions.

Supply and Power Conversion

The inverter accepts a 230 V AC supply. The input is rectified and stored on a DC bus. An inverter stage switches the DC voltage to produce a variable frequency and variable amplitude output. By changing the output frequency, the synchronous speed of the motor changes, and the shaft speed follows. Voltage is adjusted with frequency so that magnetic flux in the motor remains within design limits.

Control Methods

Linear voltage frequency control is available for simple applications such as fans and pumps, where precise torque control at low speed is not required. Sensorless vector control improves torque accuracy and is suitable for conveyors and mixers. Acceleration and deceleration ramps are adjustable so that starting current and mechanical stress are limited. Multiple parameter sets allow switching between operating profiles.

Input and Output Interfaces

Digital inputs accept start, stop, and direction commands as well as fault reset. Analog inputs accept speed or torque references from a controller or potentiometer. Relay and transistor outputs report running status, fault condition, and threshold crossings. Depending on the G10 option set, a serial or fieldbus interface may be available for communication with a PLC or supervisory system.


Protection Functions

Protection includes overcurrent, short circuit, ground fault, overvoltage, undervoltage, and overtemperature monitoring. Motor overload protection uses a thermal model that considers the current profile and the motor cooling characteristics. When a fault occurs, the inverter disables the output, signals the fault, and stores the event. This protects the motor, the inverter, and the mechanical system from damage.

Thermal Design and Installation

The inverter must be mounted in a cabinet with adequate airflow. Heat is generated mainly in the power semiconductors. Clearance above and below the unit allows natural convection, while forced ventilation may be needed in dense installations. Power cables should be shielded to limit radiated emissions, and the shield should be bonded to cabinet ground. Motor cables should be kept short where possible.

Commissioning

Commissioning begins with entering motor nameplate data such as voltage, current, frequency, power, and speed. The inverter then performs motor identification to determine electrical parameters. Reference and ramp settings are configured to match the process. Input and output functions are assigned according to the machine wiring. Parameters are saved and a backup is taken for service use.

Applications

Typical applications include pumps, fans, conveyors, mixers, and general machinery. In pumps and fans, the inverter reduces energy consumption by lowering speed when full flow is not required. In conveyors, soft starting reduces mechanical stress on the belt and gearbox. The 230 V AC supply makes the inverter suitable for smaller machines and retrofit projects.

Energy Efficiency

Because motor power consumption follows the cube of speed in many fluid applications, reducing speed substantially reduces energy use. The inverter allows the process to operate at the exact speed required instead of using mechanical throttling. This reduces wear and improves process stability while lowering operating cost.

Maintenance and Service

Inspect cooling fans and filters regularly and replace them when worn. Check terminal tightness at planned intervals. Keep the cabinet closed to prevent dust ingress. Store parameter backups outside the inverter. When replacing a unit, confirm that the firmware version and parameter set match the original to maintain machine behaviour.

Selection Considerations

Verify the motor power, current, and voltage. Confirm that the supply voltage and frequency match the inverter rating. Check that the G10 and FA options provide the required control and communication functions. Consider ambient temperature and cabinet cooling when choosing the mounting position. Ensure that cable lengths and shielding meet the installation requirements.

Conclusion

The LUST LTI DRIVES VF1204S G10 FA is a 0.75 kW frequency inverter for 230 V AC supply. It supports adjustable speed control, energy efficient operation, and reliable protection for industrial motors. With correct selection and commissioning, it contributes to stable and productive machine operation.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide
  • ASEM HT2150 Industrial Tablet Selection and Troubleshooting
  • Troubleshooting and practical application of Advantest U3771/3772 microwave spectrum analyzer
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications