Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Lust LTI Drives EMC100.1 Network Filter
    ❤ Add to collection
  • Lust LTI Drives EMC100.1 Network Filter

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥16437.00
      ¥17754.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.160KG
    • Quantity:
    • (Inventory: 32)
Description
<span style="font-size: 18px; font-family: arial;">Lust LTI Drives EMC100.1 Network Filter</span>

Lust LTI Drives EMC100.1 Network Filter

The Lust LTI Drives EMC100.1 is a network filter designed for industrial drive systems. It is rated for 3x 100 A and is installed on the supply side of the drive to reduce electromagnetic interference. The filter supports compliance with EMC requirements and helps protect sensitive equipment on the same network from conducted noise generated by the drive. It is intended for cabinet mounting and for use with compatible LTI drive controllers.

Function and Purpose

Drive systems use fast switching power semiconductors, which generate high frequency noise on the supply cables. This noise can interfere with other equipment, communication networks, and radio reception. The EMC100.1 filter attenuates this noise by providing a low impedance path for high frequency currents and by blocking their propagation back onto the supply network. This supports compliance with conducted emission limits and improves the electromagnetic compatibility of the installation.

Construction and Design

The filter contains inductive and capacitive elements arranged to form low pass filter stages. Common mode chokes reduce noise currents that flow in the same direction on all phases. Differential mode chokes and capacitors reduce noise that flows between phases. The components are housed in a metal enclosure that provides mechanical protection and shielding. Terminals are sized for the rated current and for the connection of supply and drive cables.

Electrical Characteristics

The 3x 100 A rating defines the maximum continuous current per phase that the filter can carry. The insertion loss characteristics describe how much the filter attenuates noise at different frequencies. The voltage rating must be suitable for the supply voltage of the installation. The filter is designed to handle the inrush current and the short circuit current that can occur during normal operation and during faults.

Thermal Considerations

Current flowing through the filter produces heat in the windings and in the capacitors. The filter is designed to dissipate this heat through its surface and through the mounting panel. In cabinets with several filters or drives installed close together, forced ventilation may be required. The ambient temperature must remain within the specified range. The filter should not be mounted near temperature sensitive components.


Installation Guidelines

Mount the filter close to the drive input and keep the cable between filter and drive as short as possible. Connect the supply to the input terminals and the drive to the output terminals. Observe the correct phase sequence. Use cables sized for the rated current and tighten terminals to the specified torque. Ground the filter housing to the cabinet ground with a low impedance connection. Route power cables away from signal cables.

EMC Compliance

Installations that include drives must meet electromagnetic compatibility requirements for both emissions and immunity. The EMC100.1 filter addresses conducted emissions on the supply side. Correct installation, shielding of motor cables, and proper grounding of the cabinet are also required to achieve compliance. The filter should be selected according to the drive current and the required attenuation level.

Applications

The EMC100.1 is used in packaging machines, printing equipment, textile machines, handling systems, and general industrial drives. It is particularly useful where the drive is connected to a supply that also feeds sensitive equipment, or where several drives operate on the same network. It is also used in installations where EMC limits must be respected for regulatory reasons.

Maintenance and Service

The filter requires little maintenance. Periodically inspect terminals for tightness and signs of overheating. Check the capacitors for swelling or leakage. Verify that the mounting is secure and that cooling paths are not blocked. If a filter is replaced, confirm that the current rating and attenuation characteristics match the original.

Selection Considerations

Select the filter according to the drive input current, the supply voltage, and the required attenuation. Confirm that the continuous current rating is sufficient for the application. Check that the thermal design of the cabinet can accommodate the losses of the filter. Verify that the installation meets the EMC requirements of the machine and the applicable standards.

Conclusion

The Lust LTI Drives EMC100.1 is a 3x 100 A network filter for industrial drive systems. It reduces conducted emissions, supports EMC compliance, and protects sensitive equipment on the supply network. With correct selection and installation, it contributes to stable and compliant operation of the machine.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide
  • ASEM HT2150 Industrial Tablet Selection and Troubleshooting
  • Troubleshooting and practical application of Advantest U3771/3772 microwave spectrum analyzer
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications