YOKOGAWA 701922 Differential Probe
YOKOGAWA 701922 Differential Probe
Product Overview
Make and model: YOKOGAWA Differential Probe Type 701922.
Main applications: Used with oscilloscopes for accurate measurement of high-speed differential signals.
SPECIFICATIONS
Bandwidth: DC to 200MHz
Attenuation ratio: 10:1
Connector Type: BNC (works with virtually all scopes)
Input Resistance: 500kΩ (each side to ground)
Input Capacitance: 7pF (each side to ground)
Rise Time: not specified
Differential Input Voltage Range: +/-20V
Common Mode Input Voltage Range: +/-60V
Max Ground-Referenced Input Voltage: +/- 60V (DC + ACpeak)
Output Voltage: +/- 2V (DC + ACpeak)
Output Impedance: 50Ω
Gain Accuracy: +/- 1%
CMRR: -80dB 100Hz, -50dB 10MHz
Cable Length: Approx 1.2m total cable length
Standard accessories included: pinchers B9852MF black & B9852MG red, 50cm ground extension.
Technical Parameters
Bandwidth:
DC to 200MHz (-3dB), which indicates that the probe is capable of accurately measuring differential signals from DC to 200MHz.
Input attenuation rate:
Fixed at 1/10, this means that the probe attenuates the input signal to one tenth of its original amplitude.
Maximum Allowable Differential Voltage:
±20V (DC+AC peak), this is the maximum differential voltage value that the probe can safely withstand.
Maximum common mode input voltage:
±60V (DC+AC peak), which is the maximum common mode voltage the probe can safely withstand.
Output Impedance:
50Ω, this is the impedance value of the output of the probe, which is crucial for matching the input impedance of the oscilloscope and ensuring the quality of signal transmission.
Product Features
•High accuracy: With a bandwidth of up to 200MHz, it can accurately capture high-speed differential signals to meet the demand for high-precision measurements.
•High safety: By limiting the maximum allowable differential and common mode input voltages, it ensures that the probe or equipment to be measured will not be damaged during use.
•Fixed attenuation rate: Simplifies the measurement process by eliminating the need to manually adjust the attenuation rate, improving measurement efficiency.
• Highly accurate current detection
• Easy current measurement
• Wide frequency bandwidth (DC to 100 MHz/50 MHz)
• Power can be supplied to the probe from DLM series and other digital oscilloscopes equipped with the YOKOGAWA probe interface.
• The probe is automatically recognized by the DLM series and other digital oscilloscopes equipped with the YOKOGAWA probe interface.
• Small size and light weight
• Enables measurement of low currents.
• Simple protection function for excessive input
email:1583694102@qq.com