Special installation process for MS2 foot pull rod cylinder: Depending on the version, it may be necessary to first unscrew the end buffer throttle valve and/or measuring joint for fixing with installation screws - ① Before installation, use a socket or open-end wrench to unscrew the throttle valve/measuring joint; ② Tighten the rod cylinder to the machine/system with mounting screws at the foot; ③ Reinstall to the original position using a manual torque wrench. Tightening torque gauge: The piston Ø 25-63 mm of the end buffer throttle valve (both sides) is 4.5 Nm, and the 80-200 mm is 20 Nm (SW7 wrench, ± 5%); Measure the joint (both sides) with a torque of 18 Nm for 25-63 mm and 40 Nm for 80-200 mm (SW17 wrench, ± 5%). Connect the proximity switch or position measurement system power supply according to the electrical circuit diagram.
Debugging: flushing isolation, liquid filling and exhaust, and buffering settings
Before operation: Check the sealing of the machine/system; Check the safety status of electrical and hydraulic pipelines (all flange screws and joints are tightened in place).
Flushing rules (the most easily overlooked destructive risk): When flushing the machine/system, the hydraulic cylinder must be disconnected from the system - otherwise, dirt particles will cause permanent damage; Measures must be taken to exclude the hydraulic cylinder from the flushing program. Confirm that the cleanliness of the hydraulic oil does not exceed the allowable level before commissioning.
Oil cleanliness hardness index: The basic pollution level of hydraulic oil filled must not exceed ISO 4406 © 20/18/15; The cleanliness level specified for each component (such as valves) in the system must be followed.
Nine step process of liquid filling and exhaust (starting from the retracted hydraulic cylinder in a horizontal position):
Ensure that the hydraulic circuit diagram is clear and readable;
Place a suitable collection tank to receive the leaked exhaust oil;
Open the exhaust screw on the piston rod side (at the cylinder head) of the depressurized hydraulic cylinder;
When there is a measuring connector, connect it to a hose for exhaust (with a built-in one-way valve);
Set the hydraulic system to ensure that the cylinder port pressure does not exceed 5 bar;
Connect the hydraulic system;
Switching the control valve causes the cylinder to retract at an extremely low speed (with pressure applied on the piston rod side) - the annular chamber on the piston rod side is filled with oil, and air is discharged through the exhaust port/measuring joint; The absence of bubbles in the oil indicates sufficient exhaust (only valid when the exhaust point is at the highest point);
Shut down the hydraulic system and tighten the exhaust screw;
Exhaust the bottom side of the cylinder in the same way, and after completion, the hydraulic cylinder can be put into operation.
Differences in the operation of four exhaust structures: safety exhaust port type - use a hex wrench to tighten the exhaust bolt to the safety plug screw. After filling, if there are no bubbles in the oil flowing out, it is considered to be completely discharged. When closing, tighten to the internal stop point until there is no leakage; Hexagonal exhaust screw type - only unscrew half a turn, tighten to ensure no oil leakage when closing; One way valve type - unscrew half a turn of the hexagonal exhaust screw and close the oil seal; Measurement joint type - unscrew the end cap and connect the pressure measuring hose to the stop point. When removing the pipe, the spring will press the valve core back to the valve seat, and reinstall the end cap to prevent dirt and damage.
End buffer setting (Warning level safety precautions): It is strictly prohibited to unscrew the entire throttle valve (if the throttle valve loses control and flies out, it will endanger life) - it can only be set by adjusting the throttle bolt. The full damping capability is only achieved when the throttle valve is closed; The factory state is the maximum buffering effect (tightening the throttle bolt to the bottom to close the oil passage), and unscrewing the throttle bolt increases the buffering zone speed - a higher terminal stopping speed must be considered. The locking throttle bolt cannot be fully unscrewed; For the lock nut type, first loosen the nut and adjust the hex wrench to the desired damping before re locking and positioning.
Proximity switch: Inductive proximity switch serves as a reliable end position control, with a voltage resistance of up to 500 bar and non-contact wear free design; Factory set, switching distance cannot be adjusted, locking nut marked with sealing wax; Both sides of the dual end configuration cylinder are equipped with proximity switches. Adjusting the proximity switch on your own will void the warranty!
After shutdown, put it back into operation: follow all the requirements for the first debugging.
Operation and maintenance: 70% of faults are caused by oil
According to DIN 31051, maintenance consists of three domains: maintenance (maintaining the specified state), inspection (determining and evaluating the actual state), and repair (restoring the specified state). Industry experience data: 70% of hydraulic system and cylinder failures and damages are indirectly caused by hydraulic oil - therefore, the primary inspection and maintenance task is to check and maintain the oil state (condition, cleanliness level). Ensure that no foreign objects enter the hydraulic circuit.