The benchmark for the curve value is the average oil temperature of+45 to+65 ℃ with the throttle valve closed; Special buffering versions can be customized for special applications with extremely short travel time, high speed, or large mass; Special measures must be taken when using fixed or adjustable stops.
Buffer length: 21-25 mm on both sides of the Ø 40-125 cylinder head/bottom, 33-37 mm for Ø 140-200, 76 mm for Ø 220, and 81-90 mm for Ø 250-320. Speed/cycle time is limited when the stroke is within the buffer length - it is recommended that the minimum stroke be greater than the buffer length plus 10 mm. This is also the reason for the X * min clause in installation forms such as MF3/MT4.
Position measurement system (CSH1 exclusive) and proximity switch
Magnetostrictive Position Measurement System: Non contact absolute measurement, IP67 (connector professional installation)/IP68 (cable outlet), EMC emission according to EN 61000-6-3 and EN 61000-6-2 immunity, with CE mark. Eight output interfaces: analog 4-20 mA (C), 0-10 V (F, 16 bit/internal resolution 0.1 µ m), SSI digital 5 µ m asynchronous (D) and 1 µ m synchronous (S), Profibus D63 (N, integrated power supply) and D53 (P, independent power supply) IO-Link(L)、Profinet RT/IRT 2.3(R)。 Key technical points: The position measurement system outputs a default rotation of 180 ° relative to the selected position of the cylinder bottom oil port - the oil port orientation selection (field 10/11) is directly coupled with the measurement system interface occupation, and the N/P/R type additionally occupies the cylinder bottom side outlet (size H/L7/L8 changes); When the measured length is ≤ 1500 mm, the connector tightening torque is 50 Nm ± 4%, and when it is>1500 mm, it is 65 Nm ± 4% (SW46/34 wrench); IO Link has a minimum travel of 50 mm and a maximum travel of 2540 mm and is not suitable for MP3/MP5 installation forms.
Inductive proximity switch: PNP normally open contact, withstand voltage of 500 bar, non-contact and wear free; Power supply 10-30 V DC (including residual ripple ≤ 15%), rated 24 V/200 mA, switching frequency 1000 Hz, action area IP68/body IP67, 1.4104 stainless steel shell, ambient temperature -25 to+80 ℃. Factory set, switching distance cannot be adjusted, locking nut marked with sealing wax - adjustment will void warranty; The proximity switch is always located opposite the oil port, with a piston diameter of 220-320 mm that does not protrude and the angled mating connector is not available. The proximity switch and position measurement system are important components for safety equipment, locking devices, and machine functional end position monitoring.
Sealing selection matrix (M/G/V/L/A/B/T/R/S)
Three selection tables cover the three dimensions of oil compatibility, environmental conditions, and working conditions. The rating system is:++=very good,+=good,+/-=depending on application parameters, -=not applicable.
Oil dimension: fully compatible with M/G/V/L/A/B/T/R/S at HL/HLP (-20 to+80 ℃); HFA (+5 to+55 ℃) only shows good A/T performance; HFC (-20 to+60 ℃) M/L/R/S unavailable, G/T/V available; HFDR/HFDU (-15 to+80 ℃) is only available in V/B/S configuration. The recommended oil temperature is around 40 ℃ - the indicated values are for reference only and may require verification of the suitability of the sealing system depending on the application.
Environmental dimension: Under standard operating conditions (-20 to+80 ℃), M/L/R/S is++, G/V/A/T is+(lower limit -15 ℃), and B is+; Extended operating conditions (+80 to+120 ℃) are only available for V/B/S (lower limit of G/V -15 ℃, lower limit of B/T/S/V -15 ℃).
Key points for distinguishing the dimensions of working conditions: static holding function for more than 10 minutes (application related to temperature) - M/L/A/B is++but G/V/T/R/S is only+or+/-; Short term static retention<1 minute for the entire series++; Zero point control (almost no amplitude, maximum frequency of 5 Hz, no more than 5 minutes) - M/G/V/L/A/B are all -, only T/R/S is available (T++, R+, S++); Stick slip crawling (minimum 0.001 m/s) - A/B unavailable, M/L/T/R/S++; Speed>0.5-0.8 m/s - standard pipeline connection not applicable, L is++, G/V/T/R/S is+/- or+; Travel>1.0 m - M only+/-, G/V/L/A/B/T/R/S is++; Shutdown period (wear and tear) - G/V/A/B is+/- or -; Undissolved air in oil - M/A/B is - (direct seal damage) or+(possible leakage), G/V/L/T/R/S is+.
This matrix is the core tool to prevent "leakage after three months of sealing due to correct selection" - for example, zero point control applications (such as press pressure positioning) must not choose M standard seals.
Sealing kit and tightening torque
The material number system of the sealing kit is indexed in four dimensions according to the cylinder series (CDH1/CGH1/CSH1), piston diameter x rod diameter combination, sealing design (M/G/V/L/A/B/T/R/S), and additional option F for the guide ring (L seal standard F, A/B seal does not support F, Ø 220-320 standard F). There are more than 250 material numbers for R900/R961- the sealing kit for the proximity switch, base plate installation, and position measurement system is an independent material number (R900885938/220-320 cylinders R900894997 for the proximity switch, base plate installation, and position measurement system); Bottom plate M/T/G/L/R/Class A R96106022- R96106189, S/B/V Class R96106243- R96106410; Measurement systems M/T/G/L/R class R900885935-R90089498, S/V class R900885937-R900894994).