Tightening torque of cylinder head and bottom screws (10.9 level): Ø 40 M8 × 4 is 23 Nm, Ø 50 M8 × 8 is 20 Nm, Ø 63 M8 × 8 is 30 Nm, Ø 80 M10 × 8 is 55 Nm, Ø 100 M12 × 8 is 100 Nm, Ø 125 M16 × 8 is 200 Nm, Ø 140 M16 × 12 is 170 Nm, Ø 160 M16 × 12 is 220 Nm, Ø 180 M20 × 12 is 350 Nm, Ø 200 M20 × 12 is 410 Nm, Ø 220 M20 Ø 250 M24 × 16 is 700 Nm, Ø 280 M24 × 16 is 800 Nm, Ø 320 M30 × 16 is 1500 Nm.
Sealing cover screws (applicable only to sealing designs A and B): Ø 160 M10 × 16 is 60 Nm, Ø 180 M12 × 16 is 80 Nm, Ø 200/220/250/280 M12 is 90 Nm, Ø 320 M12 × 24 is 90 Nm, or M16 × 16 is 230 Nm.
Stability verification and allowable stroke matrix of compression bar
Double formulas for calculating the instability of compression bars:
Euler formula (when λ>λ g): F=π² · E · I/(ν· LK ²), E=2.1 × 10 ⁵ N/mm ² (steel), I=0.0491 · d ⁴ mm ⁴;
Tetmajer formula (when lambda ≤ lambda g): F=d ² ·π · (335-0.62 ·λ)/(4 ·ν), lambda=4 · LK/d, lambda g=π·√ (E/(0.8 · Re));
Where ν=3.5 (safety factor), LK is the length of the free compression rod (according to the installation form), d is the diameter of the piston rod, and Re is the yield strength of the piston rod material.
The influence of installation form on the length of the compression rod: LK=0.7L (Class A - foot fixed head guide), LK=L (Class B - hinged hinged), LK=2L (Class C - cantilever/ear axis asymmetric arrangement). This is the fundamental reason why the MS2 foot cylinder allows a stroke of only 370-410 mm at 250 bar with Ø 40/22 rod, while the MF3 flange cylinder can reach 440-510 mm of the same specification and the CGH1 double rod structure can reach 970-1010 mm.
Core conclusion of allowable travel matrix (250 bar):
MP3/MP5: Ø 40/22 pole 55 mm (90 ° installation) to 55 mm; Ø 100/56 pole 355 mm (90 °) to 55 mm level; Ø 320/220 rod 2200 mm (90 ° vertical installation) - installation angle 0 °/45 °/90 ° directly changes the allowable stroke (90 ° vertical compression is the most unfavorable);
MF3: Small cylinder specifications of 80-140 cylinders can reach an upper limit of 2000-3000 mm at 100-200 bar, and Ø 320 cylinders have a full working condition of 6000 mm;
MF4: Ø 40/22 rod only 140 mm (90 °/250 bar) - weakest installation form; 320/220 pole 3460mm;
MT4 cylinder center ear shaft: between MF3 and MF4, Ø 40/22 rod 145 mm (90 °/250 bar);
MS2: Ø 320/220 rod 6000 mm all green, but Ø 40/22 rod only 410 mm - the allowable stroke difference between large and small cylinder specifications is one order of magnitude.
Long stroke optimization suggestion: Extending the guide and/or using a guide ring can improve the service life (recommended solutions can be applied according to the application and installation position); CSH1 must also comply with the X * max limit of the measurement system.
Coating corrosion grade and accessories
Primer: Standard RAL 5010 Gentian Blue ≥ 40 µ m (other colors as required); The diameter, sealing surface, valve installation surface, proximity switch, measuring system, measuring joint, spherical bearing, and grease nipple are not coated and are protected by solvent-free rust inhibitor. Painting is ordered according to corrosion levels CP4-CP7 (RAL color): CP4 (480 h salt spray SST+480 h condensing KKT, 120 µ m) is suitable for non heating condensable building/urban industrial atmospheres; CP5 (720 h SST+480 h KKT, 140 µ m) is suitable for silos/chemical plants/shipyards above seawater/breweries and medium salt load industrial coastal areas; CP6 (1000 h NSS+480 h KKT, 220 µ m) is suitable for near permanent condensation heavy pollution areas/high humidity corrosive industrial areas; CP7 (1440 h NSS+720 h KKT, 320 µ m) is suitable for near permanent condensation heavy pollution areas/coastal and high salt load areas at sea. Attention: The corrosion resistance level only refers to the coated cylinder area and does not include piston rods, ear shafts, etc. - special measures may be required for such areas.
Attachment independent ordering (data sheet 08006): 5-meter cable set for proximity switch (straight R913016852/angled R988064311, M12 × 1 A-coded 5-pole); Analog/SSD output pairing connector (6-pole R901511626, 7-pole R900079551, PG7); IO Link (straight R913045873/angled R901500328, M12 A-coded 5-pole); Profibus D53 (M8 4-pole R901132799, M12 B-code, cable set 5/10/15 m R901213191/R913008737/R913008738); Profibus D63 (PG9 M16 signal input R900705950/terminal plug R900722518/signal output R900705951); Profinet (M12 D-coded 4-pole R913045872 and A-coded 5-pole R913045873).
The Iron Law of Project Planning and Selection Tools
Six boundary conditions for project planning: ① The mechanical alignment of the motion axis and the installation point of the cylinder/piston rod must be ensured to avoid lateral forces on the piston rod and piston guide (if necessary, including the self weight of the MP3/MP5/MT4 cylinder or piston rod); ② Comply with the compression rod length/compression rod load of the piston rod and/or cylinder; ③ Comply with the maximum allowable travel speed corresponding to sealing suitability/load and its compatibility with oil characteristics; ④ Comply with the maximum allowable speed/kinetic energy (including external loads and overpressure) when entering the end position; ⑤ The maximum allowable working pressure must be observed in any operating state - the pressure doubling caused by the ratio of the annular area to the piston area and possible throttling points must be verified; ⑥ Avoid harmful environmental impacts such as corrosive particles, steam, high temperatures, as well as oil contamination and deterioration.