03 (Amp Junior vertical connector): IP 65 when the female connector is correctly installed;
07 (DEUTSCH DT04-2P): IP 69 K - the only choice for high-pressure and high-temperature flushing environments (food, outdoor construction machinery) when the female connector is correctly installed;
31 (350 mm bipolar sheath lead): The maximum lead size is 350 mm, and the protection level is determined by the user end connector.
Selection logic: 01/03 in the control cabinet is sufficient; Outdoor or flushing conditions must be 07 (DT04-2P, IP69K); The lead plate 31 is suitable for situations where users need to customize heavy-duty connectors.
Typical application troubleshooting
Troubleshooting direction
Check the resistance of the coil when the valve core does not move/moves slowly (nominal value table at 20 ℃); Voltage tolerance -10%/+10%; RAC rectifier fault (AC power supply type)
Fatigue or fracture of the reset spring (4) that does not return to the neutral position after power failure; Thrust washer (3) stuck
A/B port load holding failure secondary valve (8) setting drift -25-30 Nm adjustment screw reset or change VMA higher gear code
The anti cavitation one-way valve fails due to suction noise during actuator action; VUM secondary valve configuration verification
Emergency power outage requires manual operation to promote (7) mechanical top rod; Or choose the 0P/0F manual emergency option
Coil burnout voltage mismatch (12/13V mixed), continuous operation exceeding the upper limit of 50 ℃ environment, wire temperature exceeding 150 ℃
Leakage of P/T port O-ring damage; Flatness of overlay surface; Tighten the ring nut with 5 Nm