Secondary plug-in valve (8): designed for fast response and stable pressure control, with built-in reverse flow check valve to prevent cavitation - preventing A/B ports from vacuuming in load driven actuators (such as negative load lowering conditions). The adjustment point of the secondary overflow valve is a hexagonal 6mm screw with a torque of 25-30 Nm.

Technical data and oil requirements
Project values
Double solenoid valve weight 3.00 kg (6.61 lbs)
The weight of a single solenoid valve is 2.35 kg (5.18 lbs)
Environmental temperature (NBR seal) -20...+50 ℃ (-4...+122 ℉)
Oil temperature (NBR seal) -20...+80 ℃ (-4...+176 ℉)
Viscosity range 5... 420 mm ²/s
Voltage tolerance nominal voltage -10%...+10%
Continuous work schedule (when the ambient temperature is ≤ 50 ℃)
The upper limit of coil wire temperature is 150 ℃ (302 ℉)
Insulation level H
Low Voltage Directive Compliance LVD 73/23/EC (2006/95/EC), 2004/108/EC
Coil weight (EN 175301-803 connection) 0.5 kg
Oil and cleanliness: Suitable for mineral oil-based HL (DIN 51524 Part 1) and HLP (Part 2) hydraulic oils; Environmentally friendly oils (plant-based or polyethylene glycol based) should be consulted. Triple Red Line of Pollution Level: ISO 4572 β ₓ ≥ 75 X=12... 15, ISO 4406 class 20/18/15, NAS 1638 class 9- Consistent with the 20/18/15 target of Rexroth Industrial Hydraulic Systems. Special specification applications require consultation with the manufacturer.
Quick check of coil electrical parameters (basis for selecting power supply and fuse)
Code Voltage Voltage Type Power Consumption W 100% Current A 20 ℃ Coil Resistance Ω
OB 12 DC DC 36 3.00 3.97
AD 13 DC DC 36 2.77 4.68
OC 24 DC DC 36 1.53 15.67
AC 27 DC DC 36 1.32 20.42
OD 48 DC DC 36 0.75 63.6
OV 24+RAC(21.5 DC) AC 36 1.70 12.61
OW 110+RAC(98 DC) AC 36 0.37 261
OZ 230+RAC(207 DC) AC 36 0.17 1163
All coils have a unified power consumption of 36 W; AC power supply is only available through RAC rectification connection (the valve is essentially a DC coil). Coil material number matrix (16 items): OB01(R933000063)、OB03(R933000065)、OB07(R933000068)、OB31(R933000064)、AD01(R933000069)、AD07(R933000073)、OC01(R933000076)、OC03(R933000071)、OC07(R933000075)、OC31(R933000070)、AC01(R933000077)、AC07(R933000074)、OD01(R933000078)、OV01(R933000079)、OW01(R933000080)、OZ01(R933000081)—— The replacement of spare parts should correspond accurately to the code and connector type. The 12V and 13V coils with similar appearance are not interchangeable (resistance 3.97 Ω vs 4.68 Ω, incorrect installation will cause current overload).
Characteristic curve and performance limit (graded by valve core variant)
Pressure drop characteristics (measured at ISO-VG32 oil 45 °± 5 ℃, ambient 20 ℃): P>A, P>B, A>T, B>T correspond to curves 1-6 for each of the four pathways, mapped according to valve core variants - B201/B301/B401 full pathway curve 4; E201/E301/E401 are P>A/P>B curve 3, A>T/B>T curve 5; K201/K301/K401 is 3/3/5/2; E2R1 is 3/6/5/−; X301/X401 is 2/2/5/5; Y301/Y401 is 2/2/1/1 (the lowest pressure drop group in the entire pathway). Δ p from 3 bar (50 psi) to 18 bar (261 psi) corresponds to a flow rate of 0-80 l/min.
Performance limits (P>A and B>T symmetrical flow area bidirectional measurement): B201 series has curve 1 (highest load), X301/X401 curve 2, K201 series has E2R1 curve 3, E201 series curve 4, Y301/Y401 curve 5 (lowest load). Key Warning: Performance limits may change under special circuit connections - Asymmetric area applications (such as differential cylinder circuits) must recalculate the limit curve based on the actual path.
Dimensions and installation specifications
The total length of the dual solenoid valve is 253.6 mm (9.98 in), and the single-sided solenoid section is 78.7 mm (3.1 in); Valve body width 96.1 mm (3.78 in); Needle segment Ø 19 mm, length 26.5 mm; flange width 78.5 mm (3.09 in) x height 43.5 mm.
Key tightening torque:
Coil locking ring nut (Ø 26.5 mm): 5 Nm ± 10% - damaged needle tube due to over tightening, coil rotation displacement due to over loosening;
Secondary overflow valve adjustment screw (hexagonal 6mm): 25-30 Nm;
Flange connection M6 bolts (4 pieces, equipped with secondary flange components): minimum strength grade DIN8.8, torque 9-10 Nm;
Screw type manual emergency 0F: 6-7 Nm screw into the needle tube.
Refer to RE 18301-90 for information on pull rods and fastening torque; The flange specifications for coupling with ED intermediate components are shown in Note 3/Note 11 (standard type and LS channel type flanges are different). The P/T O-ring (Note 5) is responsible for sealing during stacked installation, and scratches on the installation surface are the main cause of leakage. Note 9: The required clearance of 12.5 mm for disassembling connectors must be reserved during layout. The A/B ports (Note 7) and identification labels (Note 8) are located on the front of the valve body.
Electrical connection protection level (IP level is the core of on-site reliability)
The protective capabilities of the four connection methods differ significantly:
00 Wireless Circle:——
01 (EN 175301-803, formerly DIN 43650): When the connector with seal is correctly unscrewed, IP 65- note that "correct tightening" is a prerequisite for the IP rating to be established;