Overview of System Architecture
The DIAX04 series is the second generation Digital Intelligent Drive System launched by Rexroth Indramat, which adopts a modular design concept and can flexibly combine multiple AC drives to share a power unit to build a compact drive package. HDD and HDS drive controllers are used in conjunction with AC motors such as MKD, MHD, 1MB, 2AD, etc. They belong to fast response drives and can be used as servo drives or spindle drives. Typical applications include machine tools, textiles, printing and packaging machinery, robots, and material handling equipment.
The complete digital drive system consists of the following components: configured HDS/HDD drive controller, plug-in modules, configuration type plates, contact guard, motor power cable, motor feedback cable, and AC motor body.
The HDD and HDS drive controllers are designed to work in conjunction with HVE or HVR power modules, which provide all the necessary signals and power voltages for the controller. When the power system does not have regenerative capability and requires high driving performance, a braking resistor HZB can be installed to release braking energy; If the start stop cycle is frequent, the capacitor module HZK can be selected; There is also a power connection module HZF available for selection.
Modular configuration of HDS driver controller
The HDS driver controller structure is completely modular, and the basic unit is equipped with different plug-in modules to adapt to specific functions. It is configured according to the required functions at the factory. A complete configuration based driver controller consists of five components:
1. Basic Unit - The slot is empty and serves as the carrier for power and control.
2. Instruction Communication Module - As the interface between the driver and the upper control system, SERCOS interface module DSS02.1M or analog interface module DAE02.1M can be selected.
3. Software module (HSM) - stores drive firmware (running software) and all drive parameters. The firmware depends on the selected configuration and target functionality. When the entire drive needs to be replaced, simply insert the software module into the replacement unit to complete the parameter migration. The new unit immediately has its original functions, which provides great convenience for rapid on-site maintenance.
4. Additional plug-in modules - extremely diverse types: digital I/O cards DEA04/05/06.1M with 15 inputs and 16 outputs per card, DEA08/09/10.1M and DEA28/29/30.1M with 32 inputs and 24 outputs per card plus CLC Bb output; DEF01/02.1M is used to connect incremental measurement systems with square wave outputs; DLF01.1M connected to 1Vpp/11uApp sine signal measurement system; DFF01.1M connects to a single loop GDS 1.1 measurement system; DAG01.2M connected to SSI multi cycle absolute value encoder; DZF02/03.1M connects Rexroth Indramat gear encoder; DRF01.1M is connected to an analog output measurement system (such as a rotary transformer, with a maximum input of ± 10V). **Note: Only one DLF, DZF, and DRF card can be used simultaneously and cannot be combined. **The interface card classes include ARCNET coupling card DAK01.1M, multi spindle ring link card DAK02.1M (supporting primary or backup redundant dual rings), and SSI standard absolute value encoder simulation module DSA01.1M; The CLC-D02.3M integrated control card supports centralized synchronization control of multiple digital drivers in SYNAX applications.
5. Configure nameplates - record the model codes of the entire machine, basic units, software modules, and each slot module (HDS U1-U4, HDD U1-U2). In case of malfunction, spare parts can be quickly locked based on the nameplate; Any configuration changes should be synchronized with the updated nameplate, and the actual configuration should be verified to be consistent with the nameplate before starting up.
Interpretation of Model Code
The HDS model code structure is: product group (HDS)+serial number (02/03/04/05)+version (2)+cooling method (W=built-in fan air cooling)+rated current (040/075/100/200/300A)+other versions (N=no special)+controller family (H=DIAX04)+command communication (A=analog, S/T=SERCOS)+function identification code+function version+FW firmware identification. For example, HDS02.2-W040N-HS01-01-FW. HDD02.2-W040N-HD32 is a fixed configuration dual axis controller with command code D (SERCOS), and each axis integrates a 1Vpp sine incremental measurement system interface.

Core technical parameters
Model Rated current A Continuous current (4k/8kHz) Power consumption W Weight kg
HDD02.2-W040N-HD32 40 15/10, 110 per axis, 8 per axis
HDS02.2-W040N 40 20/15 125 6.5
HDS03.2-W075N 75 40/30 220 11
HDS03.2-W100N 100 50/35 280 11
HDS04.2-W200N 200 120/80 800 19
HDS05.2-W300N 300 175/100 1200 25
Environmental conditions: The rated data is suitable for an ambient temperature of+5 to+45 ℃ and an altitude of 0 to 1000 meters. Exceeding the range requires the use of a derating factor - the temperature load factor fT decreases linearly to approximately 0.6 at 55 ℃ after 45 ℃; The altitude coefficient fH decreases after 1000 meters and is about 0.65 at 2000 meters. When both temperature and altitude exceed the standard, multiply the two coefficients and then multiply by the rated value. Protection level IP10 (EN 60529), must be installed in a control cabinet or enclosed enclosure (EN 50175 clause 6.1.3). Storage and transportation temperature -30 to+85 ℃.