Electrical Connection Specification
Safety prerequisite: Electrical work can only be carried out by certified electricians and VDE electrical tools must be used. The first five steps of the homework process are: isolation (including auxiliary circuits) → anti reclosing → confirmation of no voltage → grounding and short circuiting → shielding of adjacent live parts. After completion, the process is lifted in reverse order. Permanent magnet motors will generate a voltage of>60 V at the motor terminals when the rotor rotates - all operations can only be carried out when the motor is stationary, and it is strictly prohibited to plug or unplug connectors with power on.
Connector scheme (RLS 110/1200/1300 power supply, RGS 1000/1010 encoder): prioritize the use of Rexroth finished cables; Connect the wires according to the circuit diagram in the project planning manual; The vibration O-ring is not visible after the screw connector is fully tightened; The connection should only be made in a power-off, dry, and clean state; Prevent the connector from being subjected to external forces. When adjusting the orientation of the rotatable connector, the maximum torque for RGS1000/RGS10/RLS1 100 is 12 Nm, and for RLS1 200 it is 18 Nm. The orientation adjustment should not exceed 10 times.
Junction box scheme (RZK3100/RKL1200/RKL1300): torque of 4 screws on the cover plate is 5.9-7.1 Nm; maximum power wiring is 16 mm ² (U/V/W M6 terminal 2.5 Nm, PE M8 terminal 3.8 Nm, temperature/brake spring terminal 0.2-2.5 mm ²); Adaptation board screw 9 Nm ± 10%; Apply Loctite 243 to the cover plate screws and tighten them with 6.5 Nm ± 10%. Before installing the cover, check the condition of the adhesive sealing strip. Double cable wiring is used in situations where a single cable has limited bending radius or cross-section. F1 fuses are selected based on the current carrying capacity of the cable cross-section and installed as close as possible to the controller output. The shielding layer of the motor power cable must be extensively connected to the control cabinet on the motor side of the fuse. Unused cable entrances must be sealed to ensure dust and water resistance.
Fan wiring: Connect single-phase plug RLS0780 (115/230 V) to three-phase RLS0782 (400 V) according to the nameplate voltage; The "T" type fan has built-in thermal protection and does not require an external motor protection circuit, while the "N" type requires external configuration.
Operation monitoring and typical fault troubleshooting
The prerequisites for operation include: completing the disposal according to the storage time (running in bearings, heavy grinding and holding brakes, etc.), correctly connecting all connectors to prevent loosening, applying a holding brake voltage of 24 V ± 10% and functioning properly, ensuring that all components of the motor and drive chain are intact, and preventing key components from being ejected. The brake check and voltage adjustment should be implemented item by item.
Continuous inspection items during operation: abnormal noise, increased vibration, cleanliness of motors and fans, sealing of cooling connections, controller monitoring and diagnostic/error messages. Once deviating from the normal operating state, the machine should be stopped immediately for troubleshooting.
Typical Fault Comparison Table:
Possible causes and measures for troubleshooting
Motor not running, controller enable signal missing/controller malfunction/power supply missing/holding brake not released activation enable signal; Check according to the controller documentation; Check the control voltage; Check the activation of the holding brake
Poor balance of vibration coupling or accessories/insufficient alignment of shaft end accessories (coupling, gearbox)/loose installation screws for rebalancing; Re centering; Lock the threaded connection according to specifications
Running noise, foreign objects inside the motor/damaged bearings, shutdown → return to the factory for repair
Motor temperature is too high/temperature monitoring activation exceeds rated data operation/heat dissipation is obstructed, load reduction is carried out and selection is checked; Clean the motor; Fan cleaning and fence inspection function; Liquid cooling inspection cooling circuit
Temperature display error or failure. The temperature sensor is not connected or the sensor is damaged and connected to the sensor; Shutdown and return to the factory or connect backup sensors
Maintenance, replacement, and disassembly
Cleaning and maintenance: Excessive dirt, chips, and dust can affect the function of the motor, and in extreme cases, the motor may be scrapped - the cooling fins should be cleaned at least once a year to ensure sufficient heat dissipation area. Damaged connecting cables must be replaced immediately and the equipment must be stopped. Temporary repair of connecting wires is strictly prohibited; Regularly inspect for defects in the drag chain and ensure the integrity and fastening of the protective conductor connections.
Wear life of vulnerable parts: The life of seals and bearings varies with operating mode, speed, vibration impact, and frequent commutation. Suggest replacing bearings after 30000 operating hours (the short-term replacement interval may be earlier depending on the results of the operation inspection); It is recommended to conduct regular visual inspections on the shaft seal ring, and replace it if necessary after 5000 hours of operation. The above repair suggestions should be handled by Bosch Rexroth service.