Konica Minolta CM-3700A-U Plus spectrophotometer

F: | Au:FAN | DA:2025-09-20 | 1250 Br: | 🔊 点击朗读正文 ❚❚ ▶ | Share:

Measurement area indicator light (1X3): indicates the specifications of the measurement area.

Communication status indicator light (CONNECT): It lights up when the device is connected to the computer (connected to PC software).


Measurement process and operation steps

(1) Overview of Measurement Process

Refer to page number for step-by-step operation content

1. Connect the computer using a USB cable to connect the device to the computer 16

Connect the device to a power outlet using an AC adapter

3. Start the computer to open the connection (start the Windows system)-

4. Turn on the device power. 17. Turn on the device power

5. Start the SpectraMagic NX2 software and enable the control function-

6 Installation of calibration target mask Installation of calibration target mask (CM-A310/SAV) 18

7. Install the zero calibration box and perform zero calibration 20

8. Install the white calibration board and perform white calibration (when using the WAA function, perform it after white calibration, which takes about 20 seconds) 21

9 Installation of measurement target mask Installation of suitable measurement target mask 18

10. Set the sample and place it into device 22

11. Perform measurements using SpectraMagic NX2 software, or set the trigger measurement mode and press the measurement button on the device status panel to perform measurements-

After completing the measurement, turn off the device power, exit SpectraMagic NX2 software, and turn off the computer power


(2) Specific operational steps

Connecting Computers

In general, USB cables can be plugged and unplugged when the device is turned on, but it is recommended to connect them when the device is turned off: first turn off the device power, connect the B-type connector of the USB cable to the USB terminal of the device (make sure it is fully inserted and firmly connected), then connect the A-type connector to the USB port of the computer, and then connect the AC adapter and turn on the device power; If prompted to install a USB driver, you need to specify the USB driver that comes with the software that can connect and operate the device to complete the installation. After installation, you need to turn off the power and then turn it back on.

Attention: The USB communication of the device complies with the USB 2.0 standard; The device cannot be powered through a USB cable and needs to be connected to an AC adapter before use; When connecting/disconnecting USB cables, hold the connector tightly and do not pull or forcefully bend the cable to avoid cable breakage; Ensure that the cable length is sufficient to avoid connection failure or cable breakage caused by tension.

Connect the communication adapter

First, confirm that both the device and computer power are turned off (LED lights are not on). Connect the DC output plug of the AC adapter to the DC input terminal on the side of the device, and then connect the power plug of the AC adapter to a 100V (50/60Hz) AC socket; Note that the AC adapter (AC-A312F) that comes with the device must be used, and the plug must be fully inserted. Before plugging in or unplugging the DC output plug, make sure the power switch is turned off.

Turn on/off the power

Power on: When the power is turned off, press and hold the power button for about 1 second to turn on the power, and the LED light above the power button will turn blue; Note that when the power button is pressed, the LED light flashes to indicate that the AC adapter cannot be unplugged during the power on process.

Shutdown: Press and hold the power switch for about 3 seconds to turn off the power. The LED light will flash and then turn off; Similarly, the flashing LED light indicates that the AC adapter cannot be unplugged during the shutdown process.

Install target mask

First, pull out the sample rack in your own direction and keep it open. Then, pull out and remove the currently installed target mask or protective cover in your direction (the target mask is fixed by a magnet, and there are grooves on both sides of its contact surface with the device. Place your thumb and index finger in the grooves for easy removal; make sure the device is facing you when removing it, and remove it in a straight line to avoid tilting and damaging device components).

Then align the positioning holes of the target mask with the positioning pins of the device's target mask, and install the target mask onto the device (ensuring that the white coating surface on the inside of the target mask faces the device (CM-3700A-U Plus side), and that the text such as "SAV" on the surface faces up). Finally, restore the sample rack to its original position.

Attention: When performing zero calibration or white calibration, the target mask CM-A310 (SAV) must be used; If the target mask is installed in the wrong direction, it will not be installed correctly. It is necessary to check the direction and install it to ensure that there is no looseness or warping; Do not scratch the inner surface of the target mask (white coating surface) to avoid fingerprints or other dirt; The target mask may change color when exposed to light, and should be stored in the attachment storage space when not in use; Do not let the device have the target mask installed for a long time.

  • National Instruments cDAQ-9189 Chassis
  • National Instruments PXIe-8394 MXI Module
  • National Instruments PXIe-4112 Power Supply
  • National Instruments 778472-01 Module
  • National Instruments cFP-DO-401 Module
  • National Instruments PXIe-8379 Interface Card
  • National Instruments PXIe-7965R Module
  • National Instruments NI-9485 Relay Module
  • National Instruments 181045-01 Module
  • National Instruments TB-4302 Terminal Block
  • National Instruments PXI-2533 Matrix Switch Module
  • National Instruments PCI-6220 Analog Input Card
  • National Instruments PXI-2529 Matrix Switch Module
  • National Instruments 783732-01 Ordering Part Number
  • National Instruments PXI-6542 Digital Waveform Module
  • National Instruments PCI-1411 Image Acquisition Card
  • National Instruments PXI-6511 Industrial Digital I/O Module
  • National Instruments TPC-2012 Touch Panel Computer
  • National Instruments PXI-8101 Embedded Controller
  • National Instruments cRIO-9035 CompactRIO Controller
  • National Instruments PXIe-5114 Digitizer Card
  • National Instruments SCXI-1315 Block
  • National Instruments PXI-7842R Card
  • National Instruments PCI-6031E DAQ Device
  • National Instruments NI-9792 Gateway
  • National Instruments PXI-4132 SMU
  • National Instruments USB-5132 Digitizer
  • National Instruments NI 9244 Input Module
  • National Instruments SCXI-1163R Module
  • National Instruments PCI-6221 DAQ Device
  • National Instruments cFP-2120 Compact FieldPoint Controller
  • National Instruments cRIO-9073 CompactRIO Controller
  • National Instruments PCI-8516 CAN Interface Card
  • National Instruments PXIe-1073 5-Slot Chassis
  • National Instruments NI 9421 DSUB Digital Input Module
  • National Instruments PXI-4204 High Voltage Input Module
  • National Instruments PCI-6111 Multifunction DAQ Card
  • National Instruments cRIO-9035 CompactRIO Controller
  • National Instruments NI 9759 Powertrain Control Module
  • National Instruments 187254A-01 Ordering Part Number
  • National Instruments PXI-6624 Module
  • National Instruments cDAQ-9137 Chassis
  • National Instruments PXIe-8133 Controller
  • National Instruments 779139-01 Module
  • National Instruments FP-DI-301 Module
  • National Instruments 194021D-01L Module
  • National Instruments PXI-1000B Chassis
  • National Instruments PXIe-8510 Module
  • National Instruments PXI-6221 DAQ Card
  • National Instruments cDAQ-9188 Chassis
  • National Instruments PXI-5421 Arbitrary Waveform Generator
  • National Instruments cRIO-9023 CompactRIO Controller
  • National Instruments PCI-6221 Multifunction DAQ Card
  • National Instruments PXI-4065 Digital Multimeter Card
  • National Instruments NI 9477 Digital Output Module
  • National Instruments cDAQ-9185 TSN Ethernet Chassis
  • National Instruments NI 9147 4-Slot cRIO Chassis
  • National Instruments USB-6259 Mass Termination DAQ Device
  • National Instruments 184120F-01 Ordering Part Number
  • National Instruments PCI-4472B Sound and Vibration Module
  • National Instruments SCXI-1130 Switch
  • National Instruments VB-8012 VirtualBench
  • National Instruments PXI-7350 Controller
  • National Instruments eDAQ-9174 Chassis
  • National Instruments PXI-4461 DSA Module
  • National Instruments PCI-6280 DAQ Card
  • National Instruments PXI-6251 DAQ Card
  • National Instruments PXI-6653 Module
  • National Instruments PCI-6509 DIO Device
  • National Instruments NI 9751 Driver Module
  • National Instruments PXIe-6361 Multifunction I/O Module
  • National Instruments cRIO-9014 CompactRIO Controller
  • National Instruments PCI-7390 Motion Control Card
  • National Instruments PXI-8512 CAN Interface Module
  • National Instruments sbRIO-9636 Single-Board Controller
  • National Instruments IC-3120 Industrial Controller
  • National Instruments PCI-6220 M Series DAQ Card
  • National Instruments PXI-8176 Embedded Controller
  • National Instruments PXI-6132 S Series DAQ Module
  • National Instruments NI 9206 Analog Input Module
  • National Instruments PXI-2584 Switch Module
  • National Instruments 196541B-01L Module
  • National Instruments 778075-01 Module
  • National Instruments FP-RLY-420 Module
  • National Instruments USRP-2920 Radio
  • National Instruments PCIe-6351 DAQ Card
  • National Instruments cRIO-9040 Controller
  • National Instruments NI 9201 Input Module
  • National Instruments NI 9411 Input Module
  • National Instruments NI 9216 Input Module
  • National Instruments PCI-6221 DAQ Device
  • National Instruments PXI-4498 DSA Module
  • National Instruments PXI-6259 DAQ Card
  • National Instruments PXI-7354 Motion Controller
  • National Instruments FP-AI-110 Input Module
  • National Instruments 192172F-04L Module
  • National Instruments PXIe-8115 Controller
  • National Instruments 142931B-01L Module
  • National Instruments PXI-2503 Switch Module
  • National Instruments 776246-01 Module
  • National Instruments CFP-2110 Compact FieldPoint Controller
  • National Instruments 779429-01 Ordering Part Number
  • National Instruments NI-9149 8-Slot EtherCAT Chassis
  • National Instruments PXI-4110 Programmable DC Supply
  • National Instruments 192061-10 Ordering Part Number
  • National Instruments cDAQ-9181 Chassis Module Carrier
  • National Instruments NI 9437 Digital Input Module
  • National Instruments cFP-2020 Compact FieldPoint Controller
  • National Instruments PCI-6259 Multifunction DAQ Card
  • National Instruments FP-TC-120 Thermocouple Module
  • National Instruments NI-9174 CompactDAQ Chassis
  • National Instruments PXI-6030E DAQ Module
  • National Instruments PXIe-5160 Oscilloscope
  • National Instruments PXI-4462 DSA Module
  • National Instruments PXI-8109 Controller
  • National Instruments PXI-6259 DAQ Card
  • National Instruments PXI-6030E DAQ Card
  • National Instruments cRIO-9056 Controller
  • National Instruments PXIe-8370 MXI Kit
  • National Instruments USB-6212 DAQ Device
  • National Instruments RMX-4000 Electronic Load System
  • National Instruments 785040-01 Ordering Part Number
  • National Instruments cFP-AI-110 Analog Input Module
  • National Instruments cDAQ-9189 8-Slot Chassis
  • National Instruments PXIe-4139 Source Measure Unit
  • National Instruments PXI-5620 Digitizer Module
  • National Instruments PCIe-8371 MXI-Express Card
  • National Instruments 196762B-01L Ordering Part Number