F: | Au:FAN | DA:2025-09-20 | 1020 Br: | 🔊 点击朗读正文 ❚❚ | Share:

Measurement area indicator light (1X3): indicates the specifications of the measurement area.

Communication status indicator light (CONNECT): It lights up when the device is connected to the computer (connected to PC software).


Measurement process and operation steps

(1) Overview of Measurement Process

Refer to page number for step-by-step operation content

1. Connect the computer using a USB cable to connect the device to the computer 16

Connect the device to a power outlet using an AC adapter

3. Start the computer to open the connection (start the Windows system)-

4. Turn on the device power. 17. Turn on the device power

5. Start the SpectraMagic NX2 software and enable the control function-

6 Installation of calibration target mask Installation of calibration target mask (CM-A310/SAV) 18

7. Install the zero calibration box and perform zero calibration 20

8. Install the white calibration board and perform white calibration (when using the WAA function, perform it after white calibration, which takes about 20 seconds) 21

9 Installation of measurement target mask Installation of suitable measurement target mask 18

10. Set the sample and place it into device 22

11. Perform measurements using SpectraMagic NX2 software, or set the trigger measurement mode and press the measurement button on the device status panel to perform measurements-

After completing the measurement, turn off the device power, exit SpectraMagic NX2 software, and turn off the computer power


(2) Specific operational steps

Connecting Computers

In general, USB cables can be plugged and unplugged when the device is turned on, but it is recommended to connect them when the device is turned off: first turn off the device power, connect the B-type connector of the USB cable to the USB terminal of the device (make sure it is fully inserted and firmly connected), then connect the A-type connector to the USB port of the computer, and then connect the AC adapter and turn on the device power; If prompted to install a USB driver, you need to specify the USB driver that comes with the software that can connect and operate the device to complete the installation. After installation, you need to turn off the power and then turn it back on.

Attention: The USB communication of the device complies with the USB 2.0 standard; The device cannot be powered through a USB cable and needs to be connected to an AC adapter before use; When connecting/disconnecting USB cables, hold the connector tightly and do not pull or forcefully bend the cable to avoid cable breakage; Ensure that the cable length is sufficient to avoid connection failure or cable breakage caused by tension.

Connect the communication adapter

First, confirm that both the device and computer power are turned off (LED lights are not on). Connect the DC output plug of the AC adapter to the DC input terminal on the side of the device, and then connect the power plug of the AC adapter to a 100V (50/60Hz) AC socket; Note that the AC adapter (AC-A312F) that comes with the device must be used, and the plug must be fully inserted. Before plugging in or unplugging the DC output plug, make sure the power switch is turned off.

Turn on/off the power

Power on: When the power is turned off, press and hold the power button for about 1 second to turn on the power, and the LED light above the power button will turn blue; Note that when the power button is pressed, the LED light flashes to indicate that the AC adapter cannot be unplugged during the power on process.

Shutdown: Press and hold the power switch for about 3 seconds to turn off the power. The LED light will flash and then turn off; Similarly, the flashing LED light indicates that the AC adapter cannot be unplugged during the shutdown process.

Install target mask

First, pull out the sample rack in your own direction and keep it open. Then, pull out and remove the currently installed target mask or protective cover in your direction (the target mask is fixed by a magnet, and there are grooves on both sides of its contact surface with the device. Place your thumb and index finger in the grooves for easy removal; make sure the device is facing you when removing it, and remove it in a straight line to avoid tilting and damaging device components).

Then align the positioning holes of the target mask with the positioning pins of the device's target mask, and install the target mask onto the device (ensuring that the white coating surface on the inside of the target mask faces the device (CM-3700A-U Plus side), and that the text such as "SAV" on the surface faces up). Finally, restore the sample rack to its original position.

Attention: When performing zero calibration or white calibration, the target mask CM-A310 (SAV) must be used; If the target mask is installed in the wrong direction, it will not be installed correctly. It is necessary to check the direction and install it to ensure that there is no looseness or warping; Do not scratch the inner surface of the target mask (white coating surface) to avoid fingerprints or other dirt; The target mask may change color when exposed to light, and should be stored in the attachment storage space when not in use; Do not let the device have the target mask installed for a long time.

  • Metso Valmet BIU4 A413146 Binary Input Unit
  • Valmet AIU-8 Simulateur Board 421522-1a Analog Simulator
  • Valmet BIU8A Binary Input Unit 542803-3B M851222 M1
  • Valmet IQ Web Color DH Photoelectric Sensor A418182 2.04
  • Valmet A413200 AIU-8 Simulator Board 191151 421522-1A
  • Valmet Automation SCU M851006 System Control Unit Module
  • Valmet 857565/851565 Damatic Keyboard IP40 5V Operator Interface
  • Valmet A413077 FBC2 Module Rev 06 Field Bus Controller
  • Valmet DMU 2 PCB Module 545142-3A DM Data Management Unit
  • Valmet AIU16T PCB Card M851208 Analog Input Module
  • Valmet A413181 PLU Board
  • Valmet m851006 SCU Module
  • Valmet Metso 181226 Digital Input Module
  • Valmet AIU16T Analog Input Module - 16-Channel 65421466-2B MT924 V1.3
  • Valmet WIN3136875 Slide Clutch
  • Metso Valmet TIU61 A413111 Temperature Input Unit
  • Valmet MC12S Slitter Motor
  • Valmet A413139 AOH4 Board - Analog Output High Module
  • Valmet A409001 BIU85 Board
  • Valmet A413063 DMU Board
  • Valmet A413325 IPU I/O Power Unit
  • Valmet M851004 M2 CPU Module
  • Valmet IOP345 Digital Input Module
  • Metso Valmet A413215 Communication Board
  • Valmet DIFF-EL 80 M1 Transmitter
  • Valmet A413001 CPU Module
  • Valmet M899520 TDC-2 Module
  • Valmet A409001 BIU85 Board
  • Metso Valmet A413005 CPU Module
  • VALMET PUD 10 B Process Automation Rack with CPU SCU Module
  • Valmet A413091 GDU1 Board
  • VALMET M851006 M2 SCU Module
  • Lyngso Valmet Marine 990.896.000 Position Loop Card
  • Valmet Cooking Liquor Measurement 3417H
  • VALMET ABMB MT831 PCB Card
  • Valmet Automation A413325 IPU I/O Power Unit
  • Valmet Metso Consistency Transmitter Smart Pulp M2
  • VALMET METSO A413274 Connection Module
  • VALMET PI33S1KSA02RSA-ELI26 Switch
  • VALMET ND9103HN-CE07-K05 Intelligent Valve Controller
  • VALMET PMB 2R 16 Slot Backplane PCB Card
  • NELES VALMET A413135 AOU 4 Output Module
  • Metso Valmet A413345 FPU Power Unit
  • VALMET A413171 PIC Module
  • VALMET A413620 Repeater Module
  • Valmet M851521 Memory Card
  • Valmet DIFF-EL 140 M1 Transmitter
  • Valmet A413064 DMU Module
  • Valmet IOP371 I/O Bus Extender Module
  • Valmet Cooking Liquor Measurement 3400 Model 3417H
  • Metso Valmet A413043 CPU Module – Industrial Processor
  • Valmet BIU4 M851221 Binary Input Module
  • Valmet PMB 1S CPU SCU Rack Module
  • Valmet A413248 Controller Module
  • Valmet PDP601 Distributed Processing Unit
  • VALMET M851004 M2 CPU Printed Circuit Board Module
  • Metso Valmet A413045 Ver.05 CPU Module
  • Valmet A413181 Ver.05 PLU1 Board
  • Lyngso Valmet ATB16 Controller Board
  • VALMET AIU 16 Analog Input Unit 545100-3A/3B
  • VALMET PUD 10 B Power Supply PCB Rack Module
  • Valmet MS-50V/120V Bearing Unit
  • Valmet PDP603 Distributed Processing Unit – DPU Module
  • Valmet A413110 TIU Board – Terminal Interface Unit
  • Valmet S420154 I/O Backplane PCB – Printed Circuit Board
  • Valmet A413173 Industrial Control Module
  • Valmet A413044 CPU Module
  • Valmet A4IU1 Analog I/O Module
  • Valmet A413325 IPU Power Unit – PLC Module
  • Valmet M851002 CPU Module – Central Processing Unit
  • Valmet PUD10B Power Supply Board
  • Valmet K00990 Master CPU Electronic Assy
  • Valmet Metso IOP345 Input Module
  • Metso Automation T545215 Board
  • Valmet Metso IOP304 Input Module
  • Valmet 542844-6A SCU Module
  • Metso A413043 Ver.11 Valmet CPU Module
  • Valmet Automation BIU 8A Input Module
  • Metso A413044 Ver05 Valmet CPU Module
  • VALMET 542821-5A Control System Rack Module
  • Metso A413005 Ver.04 Valmet CPU Module
  • Valmet M851207 AIU16 Card
  • Valmet BIU8 Binary Input Unit
  • VALMET 547070-2B CPU Printed Circuit Board Module
  • Valmet Automation A413325 Power Module
  • VALMET AUTOMATION A413135 AOU4 Module
  • VALMET ACU A413165 Model 9 Analog Controller
  • VALMET AUTOMATION A413511-02 Slot Rack with I/O Backplane
  • Valmet A413148 BIE 4 Rev 08 Board
  • Valmet ATB16-4 Controller Board
  • Neles Automation BOR82 A413292 Processor Module
  • Valmet A413015 NCU Module – Network Control Unit
  • Valmet AIU 16 Analog Input Unit – M8512071
  • Metso Valmet A413091 GDU Board
  • Valmet M851565 Damatic Main Keyboard
  • Metso A413082 CPU Module
  • Valmet A403037 GDC – Graphics Display Controller
  • Valmet A413076 FBC Board
  • Valmet A413015 NCU Module – Network Control Unit
  • Valmet A413082 CPU Module
  • VALMET AUTOMATION A413620 Fieldbus Repeater
  • Valmet Metso IOP341R Positioner Module
  • Metso A413082 Ver.04 CPU Module
  • Valmet Metso MCA FT250/10 10 Inch Sensor
  • Valmet N0542 ABMB Printed Circuit Board
  • Valmet A413000 Ver.07 CPU Module
  • Valmet A413061 Ver.05 DMU Module
  • Valmet M851241 M1 BCU Binary Input Module
  • Valmet Automation NCU A413015 Circuit Board
  • Valmet A413046 Ver.06 CPU Module
  • Valmet A651B001 Panel Mount Keyboard
  • Valmet IQ Scanner A418080R Basis Weight Detector Head
  • Metso Valmet A413370 ESU Ethernet SCSI Unit
  • Valmet A413340 FPU Power Supply Unit
  • Valmet SKF GE 400/600 Spherical Plain Bearing
  • Valmet SCU PCB Card 542844-7B – System Control Unit
  • Valmet A413075 FBU Fieldbus Controller Module
  • Valmet A413171 PIC Card Binary Output
  • Valmet A413002 Ver.05 CPU
  • Valmet ABMB PCB Card – Industrial Control Board
  • Valmet PMB 2R 542821-4A PCB Card
  • Metso Valmet A413001 CPU Module
  • Metso Valmet A413050 RSU 6 Serial Controller Unit
  • Valmet ABMB MT241 Input Mother Board
  • Valmet DAMATIC M851565 Keyboard
  • Valmet A413075 Ver05 FBC Board
  • VALMET K14891 FLEXI-U Operating Terminal
  • VALMET AUTOMATION MKB2 DAMATIC Keyboard