Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

YASKAWA MEMOCON-SC 2000 series reversible counter module

F: | Au:FAN | DA:2025-12-26 | 613 Br: | 🔊 点击朗读正文 ❚❚ | Share:

YASKAWA MEMOCON-SC 2000 series reversible counter module

Core specifications of the product

1. General specifications

Category parameter details

Working environment temperature: 0~55 ℃ (storage: -20~85 ℃); Humidity: 10~90% RH (without condensation)

Environmental restrictions: no explosive, flammable, or corrosive gases; No severe vibration/impact (compliant with JIS C0911/C0912 standards)

Electrical performance and insulation strength: 1500VAC/1 minute; Insulation resistance: ≥ 100M Ω (500VDC); Anti noise: 1500V (noise simulator)

Physical dimensions: 38 (width) x 250 (height) x 104 (depth) mm (including terminal block); Weight approximately 0.6kg

Power consumption 5VDC ± 3%, 0.25A (internal consumption current)

2. Performance specifications

Detailed description of core parameters

Counter configuration with 2 independent counter circuits, supporting separate configuration function

Count digit GL20 adaptation: 6-digit decimal (0~999999); GL60S adaptation: 8-bit decimal (0~99999999)

Counting speed multiplier X1: 50kpps; X2:100kpps; X4:200kpps

Pulse input supports voltage levels of 5VDC, 12VDC, and 24VDC; Input mode: Phase A/B pulse, signed pulse

External coincidence output capability: open collector, maximum load 29V/250mA; Response time ≤ 5ms

External signals support external counting enable, external reset, and external sampling (1 counter per channel)

Test Input Common ADD Test (TST1), SUBTRACT Test (TST2) Input (Supports 12V/24V)


System configuration and installation requirements

1. System composition

Core components: Power module → CPU module → B2801 reversible counter module → Other I/O modules → Programming panel (P150) → Pulse generator

Connection relationship: The CPU module communicates with B2801 through the I/O interface, and external devices (pulse generators, sensors) are connected to B2801 through terminals, supporting multi module expansion

2. Installation specifications

(1) Environmental requirements

Prohibited installation scenarios: direct sunlight, temperatures exceeding 0-55 ℃, humidity>95% or condensation, contact with water/oil/chemicals, areas with severe vibration/impact

Installation operation: The fixing screws need to be tightened and checked regularly; Unused connector cover plates must not be removed (to prevent foreign objects from entering)

(2) Wiring requirements

Power specification: Use a power supply that meets the rated specifications to avoid overload and fire hazards

Anti interference measures:

The signal line adopts shielded twisted pair cable, and the shielding layer is grounded at a single point

The distance between the I/O line and the power line is ≥ 30cm, and bundling or wiring in the same pipe is prohibited

Install insulation transformer and noise filter on external power supply

Wiring taboos: Avoid foreign objects such as wire shavings from entering the module or installation base

(3) Switch settings

SW1: Counting bit switching (OFF=6-digit mode/GL20; ON=8-bit mode/GL60S)

SW2: Reserved unused (factory default OFF)

8c246f63-3421-4d9f-9f18-0bc94326b89d.png

Four core counter functions

B2801 supports four independent counter functions, which can be configured with two separate counters through initial settings. The counting operation is not affected by the running status of the CPU (counting can still continue when the CPU stops).

1. Comparison Counter

(1) Core functions

Basic ability: addition and subtraction bidirectional counting (supports carry/borrow), outputs coincidence signals by comparing the current count value with the preset value

Coincidence mode: 3 options (current value>preset value, current value=preset value, current value<preset value)

Signal characteristics: Coincidentally, the ON/OFF state of the output is controlled by the "output disable" signal (no output when disabled in>/<mode; reset ON state when disabled in mode)

(2) Key operations

Reset logic: When powered on, the module is reset, or switched to the comparison counter mode, the current value is reset to zero from the preset value

Notes:

When the preset value is set to the maximum value (such as 999999), the>mode does not meet the coincidence condition

When the preset value is set to 0, the<mode does not meet the coincidence condition

Coincidentally, the ON/OFF time of the signal needs to be longer than the CPU scanning time to avoid unrecognized states

(3) Ladder diagram configuration

Initial settings: Configure pulse input mode, counting multiplier, and coincidence output mode through output registers 4001-4004

Example parameters: Coincidence preset value=500, pulse input mode=phase A/B, counting multiplier=X1

2. Cyclic Counter

(1) Core functions

Basic ability: Automatically reset when the current count value reaches the preset value or counting width, repeat counting in a loop

Default configuration: After initial setting, the preset value and count width are automatically set to 100

Coincidentally output: When the target value is reached, an ON signal is output, which needs to be reset through the "output disable" signal

(2) Key operations

Count width: When set to 0, the counter stays at 0 and does not perform addition or subtraction counting

Time requirement: The preset value and counting width must meet the requirement of t>5ms (to avoid signal conflicts)

  • Basler D90 96801 100 PCB Card
  • Basler XR2002F Voltage Regulator (110 VAC, 48-480 Hz)
  • Basler SR8A-2B14B3A Regulator
  • Basler 9561500100 Module
  • Basler DECS-400 BE1-11 System
  • Basler DECS-100-B15 Excitation Control
  • Basler SCP 210 Frequency Controller
  • Basler SR4A-2B15B3A Static Voltage Regulator
  • Basler BE1-32R Power Relay
  • Basler PIA2400-17GM Power Interface Adapter
  • Basler MVC 232 Manual Voltage Control Module
  • Basler SSR 32-12 Static Voltage Regulator
  • Basler 5MW AVR Generator Voltage Regulator
  • Basler VR63-4B Voltage Regulator
  • Basler DECS-100-A05 AVR for Engine Generator
  • Basler DECS-100-B15 Automatic Voltage Regulator
  • Basler BE1-32R Directional Power Relay
  • Basler BE1-87B Differential Relay
  • Basler UFOV 260A Protective Module
  • Basler 9-2614-02-100 PCB Rev M
  • Basler DECS-100-B15 Digital AVR
  • Basler 9284900103 PS DECS-400N
  • Basler D4N3H1U Intertie Protection
  • Basler DECS-100-B15 A15 AVR
  • Basler KR4F Voltage Regulator
  • Basler BE26434 T14 Transformer
  • Basler SR8A-2B15B3A Regulator
  • Westinghouse 774B472A12 AR Relay
  • Basler DECS-100-B15 AVR
  • Basler XR2002F Regulator 110V
  • Basler SR125-E Static Regulator
  • Basler SSR 125-12 Regulator
  • Basler MOC2599 Motor Pot
  • Basler BE1-DFPR Feeder Relay
  • Basler CBS 305 Current Boost
  • Basler BE1-25 AutoSync
  • Basler MVC 300 Voltage Control
  • Basler BE3-25A AutoSync
  • Basler KR7FF Static Regulator
  • Basler 90-49000-100 Regulator
  • Basler 880 kVA Dry Type Transformer Specs
  • Basler Electric BE1-25 Sync-Check Relay Specs
  • Basler SSR 125-12 Voltage Regulator Specs
  • Basler Electric BE1-851 Overcurrent Relay Review
  • Basler Electric 149D930G02 Control Sub-Assembly
  • Basler Electric BE1-81O/UT Frequency Relay Specs
  • Basler Electric BE1-51/27C Overcurrent Relay
  • Basler Electric 149D956G02 Industrial Component
  • Basler Electric BE1-51A Overcurrent Relay Specs
  • Basler Electric BE1-40Q Loss of Excitation Relay
  • Basler DECS-200 Excitation Control System
  • Basler DECS-200 Voltage Regulator 56-277V AC / 125V DC
  • Basler BE1-87T Transformer Differential Relay
  • Basler RDP-110-S1 Protection Relay
  • Basler BE1-700V Digital Protective Relay
  • Basler BE1-951 Overcurrent Protection System
  • Basler DECS-300 Digital Excitation Control
  • Basler DECS-200 Digital Excitation Control
  • Basler DECS-200-1C Excitation Control System
  • Basler DECS-200-1L Digital Excitation Control
  • Basler Electric BE1-GPS Generator Protection System
  • Basler Electric DECS-200-1C Digital Excitation Controller
  • Basler Electric DECS125-15 Excitation Control with Power Module
  • Basler Electric BE1-87G Differential Relay
  • Basler Electric BE1-11 Protection System I5A3M2P2N0EA00
  • Basler Electric DECS-200-1C Excitation Control System
  • Basler Electric BE1-11g Generator Protection Relay
  • Basler Electric DECS 125-15-B2C1 V2.0.9 Excitation Control
  • Basler Electric BE1-81O/UT3ED1JA7N2F Frequency Relay
  • Basler Electric BE1-81O/UT3EE1YB7N1F Frequency Relay
  • Basler Electric DECS-200-1L Digital Excitation Control System
  • Basler DECS125-15-B2C1 Excitation Control
  • Basler 9507900205 SSR Retrofit Voltage Regulator
  • Basler BE2000E Digital Voltage Regulator
  • Basler BE1-GPS Generator Protection System
  • Basler DECS-250-CN1CN1N Digital Excitation Control
  • Basler DGC-2020 Genset Controller
  • Basler BE1-81O UT3ED1LA7N0F Frequency Relay (Variant)
  • Basler BE1-81O UT3EE1YA9S0F Frequency Relay (Variant)
  • Basler BE1-81O Over/Under Frequency Relay
  • Basler DECS125-15 Digital Excitation Control
  • Basler Electric BE1-951 Overcurrent Protection System
  • Basler Electric BE1-700V Digital Protective Relay
  • Basler Electric APR63-5 Automatic Voltage Regulator
  • Basler Electric BE1-851 Overcurrent Protection System
  • Basler Electric DECS-250-LN1SN1N Excitation Control
  • Basler Electric BE1-87T Transformer Differential Relay
  • Basler Electric DECS-200-1L Excitation Control System
  • Basler Electric 9310300100 DECS-300 Excitation Control
  • Basler Electric SSE-N 125-4.5KW Shunt Exciter Regulator
  • Basler Electric DGC-2020HD-5NS1DNSBA Genset Controller
  • Basler Electric BE1-81-O/UT3EE1JB7N1F Frequency Relay
  • Basler Electric BE1-81T1EE1WA0N1F Frequency Relay
  • Basler Electric BE1-25M1EA6PN5R1F Sync-Check Relay
  • Basler Electric BE1-GPS Generator Protection System
  • Basler Electric DECS-250-LN1SN1N Excitation Control Rev V
  • Basler Electric DECS-250-CN2CN1N Excitation Control
  • Basler Electric BE1-50/51B-207 Overcurrent Relay
  • Basler Electric DECS-300-C0N0 Excitation Control System
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric DECS-250-LN1CN1N Excitation Unit
  • Basler Electric DECS-250 LN2SA1D Excitation Unit Specs
  • Basler Electric BE1-87T Transformer Relay Review
  • Basler Electric BE1-11 Protection System
  • Basler Electric BE1-GPS100-E4N1H1N Protection System
  • Allen-Bradley 442G-MABH-R Safety Module
  • Beckhoff CX1030-0111 PLC Assembly Profile
  • FANUC IC693CPU364 PLC Module
  • Orange Denmark Type 200816 220 PLC Specs
  • OMRON C200H-SNT31 Sysmac PLC Module
  • Allen Bradley 20AB022A3AYNANC0 PowerFlex 70
  • OMRON C200HW-PCU01 Position Control Unit
  • ABB AO845A-eA Analog Output Module
  • OMRON CJ1M-CPU22 CPU Unit
  • Allen Bradley 100-E265ED11 Contactor
  • Honeywell 51304511-100 Interface Module
  • SOLEXY BXF3S0101N0018 Gateway Module
  • OMRON CJ2H-CPU65 CPU Unit
  • Automation Direct GS2-45P0 AC Drive
  • M68-2000 2-Axis Motion CNC Controller
  • OMRON CJ1M-CPU11 V3.0 PLC CPU Unit
  • OMRON CJ1W-NC413 4-Axis Positioning Controller
  • OMRON 3G2A3-PRO16 Programming Console HMI
  • Siemens 3VT8440-2AA04-2GA2 Molded Case Circuit Breaker
  • Siemens 3RT5045 Contactor Series
  • OMRON C200HS-CPU01-E SYSMAC PLC Controller
  • OMRON C500-NC103-E Positioning Control Unit
  • OMRON CJ1W-TC001 Temperature Control Unit