Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

HIRSCHMANN MICE series modular industrial communication equipment

来源: | 作者:FAN | 发布时间 :2025-12-31 | 414 次浏览: | 🔊 Click to read aloud ❚❚ | Share:

Connect the optical fiber jumper and pay attention to the cleanliness of the optical fiber interface (to avoid dust affecting transmission);

Caution: Only use HIRSCHMANN original SFP modules, non original modules may cause compatibility issues or equipment failures.

3. Installation of MB20 expansion module

Loosen the upper and lower fixing screws on the right side of the MICE basic module (rotate 1-3 turns without completely disassembling);

Remove the side cover of the basic module;

Fix the basic module on the guide rail (if not installed);

Push the MB20 expansion module along the guide rail to fit snugly with the base module, ensuring complete interface docking between modules;

Re tighten the two fixing screws on the basic module to secure the MB20 module.

4. Debugging and Startup

Power supply connection: Connect the NEC Class 2 standard power supply voltage through the terminal block of the basic module, lock the terminal block to prevent loosening;

Status check: Observe the LED indicator light on the module - the green Power light on indicates normal power supply; The port LED (green/yellow) status reflects the connection and data transmission status of the port (specific meaning depends on device settings);

Functional testing: Verify device interconnectivity through Ping commands and industrial communication protocol testing (such as Modbus, Profinet). The PoE module needs to test whether the terminal power supply is normal.

(3) Dismantling process

Disconnect the signal line of the module (the optical fiber needs to be pulled out first to avoid breakage);

Loosen the module fixing screws (media module) or unlock the SFP module locking device (SFP module);

Smoothly unplug the module to avoid violent pulling (to prevent damage to the interface pins);

Install protective covers for idle slots to prevent dust from entering.


Safety regulations and precautions

(1) Electrical safety

Power supply limitation: All modules only support NEC Class 2 standard power supply voltage. PoE modules require 48V DC safe low voltage and are prohibited from accessing voltage beyond specifications;

Explosion proof requirements: When used in Class I, Division 2, Groups A/B/C/D explosive hazardous areas, it is necessary to ensure that the equipment has been labeled with the corresponding explosion-proof identification, and only plug and unplug modules in environments where the system is powered off or there is no concentration of flammable gases; Replacing modules may affect explosion-proof compatibility and require the use of original spare parts;

Grounding requirements: The shielding layer of Twisted Air cables should be electrically conductive with the front panel of the equipment, and avoid forming a grounding loop during wiring to prevent electromagnetic interference.

(2) Static Electricity Protection (ESD)

The module contains electrostatic sensitive components (such as chips and interface circuits), and operation must comply with the IEC/TR 61340-5-2 standard:

Operators need to wear anti-static wristbands or touch grounded metal objects to release static electricity;

When storing modules, they should be placed in anti-static packaging bags to avoid contact with materials that are prone to static electricity, such as synthetic fibers and plastics;

It is prohibited to touch the exposed metal parts of the module's pins, interface gold fingers, etc. with your hands.

(3) Electromagnetic Compatibility (EMC)

The equipment has a Class A electromagnetic radiation rating and may cause radio interference when used in residential areas. Users are responsible for eliminating the interference themselves;

Strictly follow the wiring specifications in the manual during installation, use shielded cables (such as STP network cables), and avoid parallel laying with power cables (minimum spacing ≥ 30cm);

The equipment must meet the following EMC anti-interference standards:

Electrostatic discharge (EN 61000-4-2): Contact discharge ± 6kV, air discharge ± 8kV;

Electromagnetic radiation (EN 61000-4-3): 80~3000MHz, 10V/m;

Surge (EN 61000-4-5): Power port ± 4kV, data port ± 2kV;

Fast transient pulse (EN 61000-4-4): power port ± 2kV, data port ± 4kV.

(4) Environmental safety

Temperature limit: Standard module working temperature is 0 ℃~+60 ℃, expansion type (T/E grade) working temperature is -40 ℃~+70 ℃, storage temperature is -40 ℃~+85 ℃ (E grade with Confocal Coating anti condensation coating);

Humidity and air pressure: working humidity of 10%~95% (no condensation), maximum altitude of 2000m (795hPa), if exceeding the altitude, please consult the manufacturer in advance;

Pollution level: The environmental pollution level for use must be ≤ 2 (in accordance with IEC 60664-1), and should be avoided in environments with dust, oil, and corrosive gases. Otherwise, an enclosure with a protection level of IP54 or higher must be equipped.

(5) Other safety requirements

Cable specifications: Only use copper core wires with a temperature rating of 60/75 ℃ or 75 ℃. Twisted Pair cables require 4 pairs of types (such as Cat5e, Cat6), and PoE module cable length ≤ 3m;

Lid opening restriction: The device casing can only be opened by authorized HIRSCHMANN technicians. Unauthorized lid opening may result in equipment damage or loss of warranty eligibility;

  • TEAM BL0170 PC0010-P Industrial Controller
  • TEAM BG0090 PC0006 Industrial Control Board
  • Techno KR-505M Stepper Motor Controller
  • Teikoor CPCIAC-6U-500 CompactPCI AC Power Supply
  • TEL MBMY-001A VME Memory Board
  • TEL VME-U10 B VME Single Board Computer
  • TEL TVB-1202-1 ANET VME Bus Termination Board
  • ALSTOM GDS1168-6216 Signal Converter Module
  • Tokyo FAO111A Industrial Control Module
  • Toshiba AFX-90L-RH XRF Analyzer Tube
  • Toshiba GBU648E S Bridge Rectifier Module
  • Toshiba TCPSV Servo CPU Module J7000 Series
  • Toshiba HFAS11S Servo Drive Module
  • TOYOA MC256-C Servo Controller Module
  • TEL TVB6002-1 1308-644857-12 RF Control Interface
  • TEL TVB3101-1 1381-644957-16 RF Module Specs
  • Telemecanique BW06 Industrial Limit Switch
  • Teradyne A1004-00003 398-723-00 Interface Board
  • Leybold THERMOVAC TR301 15740 Vacuum Transmitter
  • TOKYO TK6132A8 Industrial Control Module
  • TOYOPUC OUT-16 THK-2791 PLC Output Module
  • TPC FFLC6-3483-B Industrial Interface
  • TPC FPX86-9345-B Pneumatic Control
  • TR Electronic ZE65M Absolute Encoder
  • TRACO POWER T1032-07C Industrial DC/DC Converter
  • TRACO POWER T1023-07C High-Efficiency Power Module
  • Trafo SLOV4.6/5.3 3BHL000734P0003 Isolation Transformer
  • Trafotek CHK0520 Current Transformer
  • Transcend 128MB PC133 SDRAM Memory Module
  • Transition Networks J/E-CF-02 Media Converter
  • TRASFOR DRMBW20/L 3BHB009181P0001 Drive Power Module
  • TRASFOR DRMBW30/L 3BHB009182P0001 Rectifier Transformer Module
  • Trenew VME-GrundSystem VMEbus Chassis
  • Trumpf TE 1605341 VER02 Circuit Board
  • Trumpf MBE3-50 Laser Control Electronics
  • TSC Carat 1008FC Industrial Power Module
  • Turck FDNL-L0800-T DeviceNet Fieldbus I/O Module
  • Turck MK35-LI-EX0 Intrinsically Safe Isolation Amplifier
  • Turck MK33-LI-EX0 Intrinsically Safe Inductive Sensor
  • Turck JBBS-49-E413/3 PROFIBUS DP Junction Box
  • Turck BL20-16DI-24VDC-P Digital Input Module
  • TWUNCOM J592S-450550 Dual Serial I/O Module
  • TE Connectivity KUEP-11D15-24 General Purpose Relay
  • UE LDP1WC 250P-16 Low Differential Pressure Switch
  • UniOP ETT-VGA-0045 Operator Panel
  • UniOP TCM08A Communication Module
  • UniOP ETT-VGA HMI Terminal Technical Specifications
  • Vacon PC00459G CM210901 Control Board
  • Valmet CXW D201435L Controller
  • Valmet A413305 I/O Module
  • Valmet A413280 DNA System Processor Module
  • Valmet CPR1 A413280 Processor Module
  • Valmet A413295 Valve Controller Module
  • Valmet A413285 Industrial Control Module
  • Valmet A413052 8-Channel Analog Output Module
  • Valmet A413045 Industrial Control CPU Module
  • VIBRO-METER 200-595-002-011 Interface Module
  • VIBRO-METER 573-935-202C Monitoring Module
  • VIBRO-METER VM600 MPC4 200-510-111-034 Monitoring Card
  • VIBRO-METER MPC4 200-510-076-115 Protection Monitoring Card
  • VIBRO-METER CMC16 200-530-022-014 Communication Module
  • VIBRO-METER MPC4 200-510-111-035 Machinery Protection Card
  • VAT 65040-PACV-AYU2/9049 Vacuum Valve Controller
  • Vibrack VK5488E-107S Vibration Transmitter
  • Vibro-Meter VM600 IOC16T 200-565-000-013 I/O Specs
  • Vibro-Meter 200-566-000-012 IOCN Network Interface
  • Vibro-Meter VM600 200-560-000-113 IOC4T Input Output Card
  • Vibro-Meter VM600 200-582-915-032 Power Supply
  • Vibro 573-935-202C VM600 Control Module
  • Vibro 200-595-002-011 VM600 CPUM Processor Module
  • Vibro-meter VM600 MPC4 200-510-111-034 200-510-070-113 Protection Card
  • Vibro-meter MPC4 200-510-076-115 Machinery Protection Card
  • Vibro-meter CMC16 200-530-022-014 Machinery Protection Rack
  • Vibro-meter MPC4 200-510-111-035 Vibration Monitoring Module
  • Vibro-meter CMC16 16-Slot Machinery Protection Rack
  • Vibro-meter MPC4 4-Channel Protection Card
  • Vibro-meter VM600 IOC4T 4-Channel I/O Module
  • Vibro-meter VM600 204-040-100-012 System Controller
  • Vibro-meter VM600 PNR200-570-000-111 Relay Module
  • Vibro-Meter VM600 IOCN 200-566-000-112 Network Interface
  • Vibro-Meter VM600 IOC16T 200-565-000-013 I/O Card
  • Vibro-Meter VM600 RPS6U 200-582-500-013 Power Supply
  • Vibro-Meter VM600 CMC16 200-530-022-014 Monitoring Card
  • Vibro-Meter VM600 MPC4 200-510-070-113 Protection Card
  • Vibro-meter VM600 204-040-100-012 System Controller
  • Vibro-meter VMF IOCN Network I/O Module
  • Vibro-meter VMF RLC16 Relay Output Module
  • Vibro-meter VMF IOC4T 4-Channel I/O Module
  • Vibro-meter VMF IOC16T 16-Channel I/O Module
  • Vibro-Meter CMC16 200-530-111-013 Condition Monitoring Card
  • Vibro-Meter CPUM 200-595-046-114 Advanced Rack Controller
  • Vibro-Meter MPC4 200-510-111-034 Machinery Protection Card
  • Vibro-Meter CPUM 200-595-045-114 Rack Controller
  • Vibro-Meter SIM-275A 200-582-500-013 Signal Interface
  • Vibro-Meter VM600-CSA 204-040-100-211 Redundancy Module
  • Vibro-meter VM600 204-040-100-012 System Controller
  • Vibro-meter VM600 RLC16 Relay Module
  • Vibro-meter VM600 RPS6U Redundant Power Supply
  • Vibro-meter VM600 CMC16 Machinery Protection Rack
  • Vibro-meter VM600 ABE042 System Controller Card
  • Vibro-Meter VM600 RPS6U 200-582-200-011 Power Supply
  • Vibro-Meter VM600 RLC16 Relay Card
  • Vibro-Meter VM600 IOC4T 200-560-000-018 Input Output Card
  • Vibro-Meter VM600 XIO16T 620-003-111-112 Input Output Module
  • Vibro-meter VM600 XMV16 Vibration Measurement Card
  • Vibro-meter VM600 ABE040 System Controller Card
  • Vibro-Meter 444-680-000-511 Signal Conditioning Module
  • Vibro-meter VM600 CMC16 Machinery Protection System
  • VIPA 62K-NHC0-DH Touch Panel HMI
  • VIPA 972-0DP10 PROFIBUS DP Interface Module
  • VMIC Assy 11993R2 Circuit Board Assembly
  • VMIC 11-1001245-01 Industrial Module
  • VMIC ZT5524A1A CompactPCI Intelligent Controller
  • VMIC VMIVME-2533 32-Channel Digital I/O Module
  • Vortran LST200 Laser Diode Control System
  • Vortran Stradus 405nm Laser Module
  • Vishay 120NQ045R Schottky Rectifier Diode
  • VMIC VMIVME-7740-840 Pentium III VME SBC
  • VMIC VMIVME-7740-855 PowerPC VME Single Board Computer
  • VMIC VMIVME-1128 128-Bit High Voltage Digital Input Board
  • VMIC ASSY 12149 VMEbus Single Board Computer
  • VMIC ASSY 11994R13 VMEbus Industrial I/O Module
  • Wavecrest DTS-2079 High-Performance Controller Module
  • Wurth Elektronik 74271132 WE-STAR-TEC Snap Ferrite
  • Woodward 9907-165 Digital Turbine Control Module
  • DS1230Y-150+ 256Kb Non-Volatile SRAM Maxim Integrated
  • ZIPPE MWS10/A Industrial Weighing Transmitter Module
  • ZNYX ZX370 Series Fast Ethernet PCI Adapter