Connect the optical fiber jumper and pay attention to the cleanliness of the optical fiber interface (to avoid dust affecting transmission);

Caution: Only use HIRSCHMANN original SFP modules, non original modules may cause compatibility issues or equipment failures.

3. Installation of MB20 expansion module

Loosen the upper and lower fixing screws on the right side of the MICE basic module (rotate 1-3 turns without completely disassembling);

Remove the side cover of the basic module;

Fix the basic module on the guide rail (if not installed);

Push the MB20 expansion module along the guide rail to fit snugly with the base module, ensuring complete interface docking between modules;

Re tighten the two fixing screws on the basic module to secure the MB20 module.

4. Debugging and Startup

Power supply connection: Connect the NEC Class 2 standard power supply voltage through the terminal block of the basic module, lock the terminal block to prevent loosening;

Status check: Observe the LED indicator light on the module - the green Power light on indicates normal power supply; The port LED (green/yellow) status reflects the connection and data transmission status of the port (specific meaning depends on device settings);

Functional testing: Verify device interconnectivity through Ping commands and industrial communication protocol testing (such as Modbus, Profinet). The PoE module needs to test whether the terminal power supply is normal.

(3) Dismantling process

Disconnect the signal line of the module (the optical fiber needs to be pulled out first to avoid breakage);

Loosen the module fixing screws (media module) or unlock the SFP module locking device (SFP module);

Smoothly unplug the module to avoid violent pulling (to prevent damage to the interface pins);

Install protective covers for idle slots to prevent dust from entering.


Safety regulations and precautions

(1) Electrical safety

Power supply limitation: All modules only support NEC Class 2 standard power supply voltage. PoE modules require 48V DC safe low voltage and are prohibited from accessing voltage beyond specifications;

Explosion proof requirements: When used in Class I, Division 2, Groups A/B/C/D explosive hazardous areas, it is necessary to ensure that the equipment has been labeled with the corresponding explosion-proof identification, and only plug and unplug modules in environments where the system is powered off or there is no concentration of flammable gases; Replacing modules may affect explosion-proof compatibility and require the use of original spare parts;

Grounding requirements: The shielding layer of Twisted Air cables should be electrically conductive with the front panel of the equipment, and avoid forming a grounding loop during wiring to prevent electromagnetic interference.

(2) Static Electricity Protection (ESD)

The module contains electrostatic sensitive components (such as chips and interface circuits), and operation must comply with the IEC/TR 61340-5-2 standard:

Operators need to wear anti-static wristbands or touch grounded metal objects to release static electricity;

When storing modules, they should be placed in anti-static packaging bags to avoid contact with materials that are prone to static electricity, such as synthetic fibers and plastics;

It is prohibited to touch the exposed metal parts of the module's pins, interface gold fingers, etc. with your hands.

(3) Electromagnetic Compatibility (EMC)

The equipment has a Class A electromagnetic radiation rating and may cause radio interference when used in residential areas. Users are responsible for eliminating the interference themselves;

Strictly follow the wiring specifications in the manual during installation, use shielded cables (such as STP network cables), and avoid parallel laying with power cables (minimum spacing ≥ 30cm);

The equipment must meet the following EMC anti-interference standards:

Electrostatic discharge (EN 61000-4-2): Contact discharge ± 6kV, air discharge ± 8kV;

Electromagnetic radiation (EN 61000-4-3): 80~3000MHz, 10V/m;

Surge (EN 61000-4-5): Power port ± 4kV, data port ± 2kV;

Fast transient pulse (EN 61000-4-4): power port ± 2kV, data port ± 4kV.

(4) Environmental safety

Temperature limit: Standard module working temperature is 0 ℃~+60 ℃, expansion type (T/E grade) working temperature is -40 ℃~+70 ℃, storage temperature is -40 ℃~+85 ℃ (E grade with Confocal Coating anti condensation coating);

Humidity and air pressure: working humidity of 10%~95% (no condensation), maximum altitude of 2000m (795hPa), if exceeding the altitude, please consult the manufacturer in advance;

Pollution level: The environmental pollution level for use must be ≤ 2 (in accordance with IEC 60664-1), and should be avoided in environments with dust, oil, and corrosive gases. Otherwise, an enclosure with a protection level of IP54 or higher must be equipped.

(5) Other safety requirements

Cable specifications: Only use copper core wires with a temperature rating of 60/75 ℃ or 75 ℃. Twisted Pair cables require 4 pairs of types (such as Cat5e, Cat6), and PoE module cable length ≤ 3m;

Lid opening restriction: The device casing can only be opened by authorized HIRSCHMANN technicians. Unauthorized lid opening may result in equipment damage or loss of warranty eligibility;

  • Valmet Automation PLC Module A413171
  • Valmet Automation 542852-3A Rack-Mount Cross Connect Panel
  • Valmet Marine Damatic M851565 Main Keyboard
  • Valmet TIU 6 Printed Circuit Board A413110
  • Metso Valmet U4440253V1.1 RMI CPU 300
  • Metso Valmet A413016 Ver.12 NCU2
  • Valmet M851565 Damatic Keyboard
  • Valmet ATB16-4 16 Channel Relay Card
  • Valmet Metso A413331 SPU Power Supply
  • Valmet PUD 10B Automation Control Rack
  • Valmet MT917 ABMB DMU PCB I/O Module
  • Valmet M851565 Damatic Keyboard Mkb2
  • Valmet EDS-518A-MM-SC Ethernet Gateway
  • Valmet 542836-6A PCB Card
  • Valmet ATB16-4/2 Terminal Board 9144047
  • Valmet ATB16-4 Controller Board 0-50°C 4-20mA Analog Output
  • Valmet 542852-3A Slot Rack Chassis Module
  • Valmet A413026 Ver.M1 FBC Board
  • Valmet IQ Basis Weight SH Sending Assembly A418081
  • Valmet PMB 2R Monolithic Backplane 8-Slot PCB 542821-5A and -5B
  • Valmet ATB16-4 16-Channel Relay Card Controller Board 22195028
  • Valmet Diff-EL SL6NK227SF0 Pressure Transmitter 0-380 mBar
  • Valmet A413110 TIU6 Board Ver.M1
  • Neles Automation A413278 Control Module
  • Valmet BCUTB Terminal Module 10101006 11091002
  • Valmet Senso 160 Measuring Station Display 160.2
  • Valmet AIU 1A Analog Input Unit M851245
  • Valmet IQ Web Caliper Sensor A420734
  • Valmet M851040/M8510401 Memory Board
  • Valmet AN35S1MC02RA Valve
  • Valmet M851121 M2 Cross Connect Panel
  • Valmet AIU-8 Simulator Board 421522-1A
  • Metso BIU 82 D200533 Binary Input Unit
  • Valmet M851121 M2 Module Rack
  • Valmet A413383 PC Board Module
  • Valmet N0542 NO54 ABMB PCB - 545200-3A Board
  • Valmet Metso IOP304 Input Module 181503
  • Valmet PDP601 Distributed Processing Unit 181585
  • Valmet A413084 CPU Board - Processor Module for Automation Systems
  • Valmet AIU 16T Analog Input Module M8512081 M1
  • Valmet AIU 16 Analog Input Module 545100-3A and 545100-3B
  • Metso Valmet BIU4 A413146 Binary Input Unit
  • Valmet AIU-8 Simulateur Board 421522-1a Analog Simulator
  • Valmet BIU8A Binary Input Unit 542803-3B M851222 M1
  • Valmet IQ Web Color DH Photoelectric Sensor A418182 2.04
  • Valmet A413200 AIU-8 Simulator Board 191151 421522-1A
  • Valmet Automation SCU M851006 System Control Unit Module
  • Valmet 857565/851565 Damatic Keyboard IP40 5V Operator Interface
  • Valmet A413077 FBC2 Module Rev 06 Field Bus Controller
  • Valmet DMU 2 PCB Module 545142-3A DM Data Management Unit
  • Valmet AIU16T PCB Card M851208 Analog Input Module
  • Valmet A413181 PLU Board
  • Valmet m851006 SCU Module
  • Valmet Metso 181226 Digital Input Module
  • Valmet AIU16T Analog Input Module - 16-Channel 65421466-2B MT924 V1.3
  • Valmet WIN3136875 Slide Clutch
  • Metso Valmet TIU61 A413111 Temperature Input Unit
  • Valmet MC12S Slitter Motor
  • Valmet A413139 AOH4 Board - Analog Output High Module
  • Valmet A409001 BIU85 Board
  • Valmet A413063 DMU Board
  • Valmet A413325 IPU I/O Power Unit
  • Valmet M851004 M2 CPU Module
  • Valmet IOP345 Digital Input Module
  • Metso Valmet A413215 Communication Board
  • Valmet DIFF-EL 80 M1 Transmitter
  • Valmet A413001 CPU Module
  • Valmet M899520 TDC-2 Module
  • Valmet A409001 BIU85 Board
  • Metso Valmet A413005 CPU Module
  • VALMET PUD 10 B Process Automation Rack with CPU SCU Module
  • Valmet A413091 GDU1 Board
  • VALMET M851006 M2 SCU Module
  • Lyngso Valmet Marine 990.896.000 Position Loop Card
  • Valmet Cooking Liquor Measurement 3417H
  • VALMET ABMB MT831 PCB Card
  • Valmet Automation A413325 IPU I/O Power Unit
  • Valmet Metso Consistency Transmitter Smart Pulp M2
  • VALMET METSO A413274 Connection Module
  • VALMET PI33S1KSA02RSA-ELI26 Switch
  • VALMET ND9103HN-CE07-K05 Intelligent Valve Controller
  • VALMET PMB 2R 16 Slot Backplane PCB Card
  • NELES VALMET A413135 AOU 4 Output Module
  • Metso Valmet A413345 FPU Power Unit
  • VALMET A413171 PIC Module
  • VALMET A413620 Repeater Module
  • Valmet M851521 Memory Card
  • Valmet DIFF-EL 140 M1 Transmitter
  • Valmet A413064 DMU Module
  • Valmet IOP371 I/O Bus Extender Module
  • Valmet Cooking Liquor Measurement 3400 Model 3417H
  • Metso Valmet A413043 CPU Module – Industrial Processor
  • Valmet BIU4 M851221 Binary Input Module
  • Valmet PMB 1S CPU SCU Rack Module
  • Valmet A413248 Controller Module
  • Valmet PDP601 Distributed Processing Unit
  • VALMET M851004 M2 CPU Printed Circuit Board Module
  • Metso Valmet A413045 Ver.05 CPU Module
  • Valmet A413181 Ver.05 PLU1 Board
  • Lyngso Valmet ATB16 Controller Board
  • VALMET AIU 16 Analog Input Unit 545100-3A/3B
  • VALMET PUD 10 B Power Supply PCB Rack Module
  • Valmet MS-50V/120V Bearing Unit
  • Valmet PDP603 Distributed Processing Unit – DPU Module
  • Valmet A413110 TIU Board – Terminal Interface Unit
  • Valmet S420154 I/O Backplane PCB – Printed Circuit Board
  • Valmet A413173 Industrial Control Module
  • Valmet A413044 CPU Module
  • Valmet A4IU1 Analog I/O Module
  • Valmet A413325 IPU Power Unit – PLC Module
  • Valmet M851002 CPU Module – Central Processing Unit
  • Valmet PUD10B Power Supply Board
  • Valmet K00990 Master CPU Electronic Assy
  • Valmet Metso IOP345 Input Module
  • Metso Automation T545215 Board
  • Valmet Metso IOP304 Input Module
  • Valmet 542844-6A SCU Module
  • Metso A413043 Ver.11 Valmet CPU Module
  • Valmet Automation BIU 8A Input Module
  • Metso A413044 Ver05 Valmet CPU Module
  • VALMET 542821-5A Control System Rack Module
  • Metso A413005 Ver.04 Valmet CPU Module
  • Valmet M851207 AIU16 Card
  • Valmet BIU8 Binary Input Unit
  • VALMET 547070-2B CPU Printed Circuit Board Module
  • Valmet Automation A413325 Power Module
  • VALMET AUTOMATION A413135 AOU4 Module
  • VALMET ACU A413165 Model 9 Analog Controller