Equipment Overview

The MMS 3120/xxx-xxx dual channel bearing vibration transmitter is part of the improved MMS 3000 transmitter system, used for monitoring and protecting various types of turbomachinery. This transmitter has highly flexible hardware options and multiple combination possibilities, which can best adapt to the needs of the corresponding factory. It achieves economic measurement and monitoring of absolute bearing vibration through the use of seismic absolute vibration sensors, and complies with VDI 2056/.. And API 670 standards.


Application scenarios

Suitable for various types of turbomachinery, fans, compressors, gearboxes, pumps, and similar rotating machinery. Due to its bus capability, it is suitable for both large systems equipped with programmable logic controllers and hosts (such as power plants, refineries, and chemical plants) and small factories with few measurement points and scattered data processing. Can be used in conjunction with all EPR absolute bearing vibration sensors, such as PR 9268/20, PR 9268/30, PR 9268/60, and PR 9268/70.


Function and Design

Signal conversion: Convert the signal of a vibration sensor into two independent signals proportional to the vibration velocity or amplitude (peak to peak), or output signals proportional to the maximum value of these characteristic values.

Monitoring function: Integrated module and sensor monitoring function, capable of detecting faults in sensors and module electronic devices. In the event of an error, the status of the "OK" output will change, and the 4-20 mA current output will indicate 0 mA.

Configuration method: All necessary configurations are completed through MMS 3910W configuration software. The transmitter comes with standard configurations suitable for most applications at the factory, or other configurations can be made at the factory according to requirements.

Technical parameters

Sensor Input

Two independent inputs for PR 9268/20, PR 9268/30, PR 9268/60, and PR 9268/70 seismic vibration sensors.

Sensor connection: Harting connector.

Measurement range: It can be freely selected through configuration software based on the measurement range of the applied sensor.

Frequency range (-3dB): High pass filter 5/10/15 Hz; low-pass filter 50... 1500 Hz.

output

Current output: The standard is two current outputs, proportional to the selected characteristics and related to system grounding, which can be freely allocated to the measurement channel; Choose between two electrically isolated current outputs or no current output. The output range is 0/4... 20 mA or 20... 4/0 mA, with a maximum load of 500 ohms and open and short circuit protection.

Buffer sensor signal: Two signal outputs for analysis and diagnosis, one for each channel, proportional to the dynamic sensor signal, accessed through terminals, unfiltered voltage output of ± 5.0 V, with an error of ± 2.5%.

Function output: A total of 5 function outputs are provided, which can be freely allocated through configuration software to indicate limit values or clear channel status, etc. There are multiple options, such as no function output, 5 optocoupler outputs, 5 relay contacts (normally open contacts), 5 photoelectric MOS relays, etc.

Data interface: The standard is RS 232 interface, used for transmitter configuration and measurement data display; Optional RS485 bus (with epro protocol V2.0) and PROFIBUS DP.

Accuracy and stability

Linear error (without sensor): 0.2% at 25 ° C.

Linear error (with sensor):<2.2% at 25 ° C.

Output temperature stability:<0.08%/10K.

Long term drift: up to 1% of full scale.

Power supply: Optional redundant power supply, with diode decoupled LED, nominal voltage+24 V DC, voltage range+18...+31.2 V DC, power consumption depends on built-in options, maximum 6 W.

Shell and Protection

Shell: Aluminum, non corrosive.

Protection level: IP 65 (compliant with DIN 40050, IEC 144), CE certification, EMC testing in accordance with EN 55011 and EN 61326.

Environmental conditions (compliant with IEC 359, DIN 43745)

The maximum allowable temperature for installation surface is 65 ° C (90 ° C when installed on bolts with a spacing of 10mm).

Working temperature range: -20...+65 ° C (-20...+45 ° C when installed on 10 mm spaced bolts).

Allowable relative humidity: 0... 95%, no condensation.

Vibration and impact: impact 20 g/2 ms; Vibration at 5 g/60 Hz.

Installation and Dimensions: The preferred installation direction is downwards with the cable gland. Please refer to the drawing for the dimensions. The maximum net weight is 1.3 kg and the maximum gross weight is 1.5 kg.


Module and sensor monitoring

Internal module monitoring continuously checks the following functions: whether the input signal is within the predefined range; Is the cable between the transmitter and sensor normal (no short circuit/broken wire); System voltage. The monitoring status of modules and sensors can be signaled through the switch contacts of functional outputs.


Configure parameters and operating modes

Main configuration parameters: configured through MMS 3910W configuration software, adjustable parameters include KKS identification for each channel, operating mode, sensor sensitivity, series resistance of safety barriers, measurement range, etc. (may vary depending on the selected operating mode and measurement function).

  • National Instruments cRIO-9112 Chassis
  • National Instruments PXIe-1078 Chassis
  • National Instruments PCIe-6536 DIO Board
  • National Instruments NI-9425 Input Module
  • National Instruments PCI-5122 Digitizer Card
  • National Instruments 779072-01 Relay Module
  • National Instruments 783703-01 DAQ Module
  • National Instruments PXI-6515 Digital Module
  • National Instruments 781099-01 DAQ Device
  • National Instruments PXI-8183 PXI Controller
  • National Instruments sbRIO-9626 Single-Board RIO Controller
  • National Instruments PXIe-1435 Camera Link Frame Grabber
  • National Instruments NI 9237 Strain Bridge Input Module
  • National Instruments PXIe-4353 Thermocouple Input Module
  • National Instruments PCIe-6320 X Series DAQ Card
  • National Instruments NI 1454 Compact Vision System
  • National Instruments PCIe-6321 X Series DAQ Card
  • National Instruments PXIe-5172 PXI Oscilloscope Module
  • National Instruments cDAQ-9134 CompactDAQ Controller
  • National Instruments cRIO-9063 CompactRIO Controller
  • National Instruments PXI-4070 DMM Card
  • National Instruments cFP-BP-4 Backplane
  • National Instruments 779521-01 Bridge Module
  • National Instruments cDAQ-9172 Chassis
  • National Instruments NI 9236 Strain Module
  • National Instruments PXI-1042Q Chassis
  • National Instruments SCXI-1102 Input Module
  • National Instruments 776990-01 Input Module
  • National Instruments PXI-1045 PXI Chassis
  • National Instruments PCIe-6251 DAQ Device
  • National Instruments NI 9219 Universal Analog Input Module
  • National Instruments NI 9215 BNC Analog Input Module
  • National Instruments PXIe-6570 Digital Pattern Instrument
  • National Instruments NI-9477 Digital Output Module
  • National Instruments NI 9145 EtherCAT Chassis
  • National Instruments PCI-6521 Industrial Digital I/O Card
  • National Instruments NI 9239 BNC Voltage Input Module
  • National Instruments NI 9265 Current Output Module
  • National Instruments NI 9212 Thermocouple Input Module
  • National Instruments PXI-6229 Multifunction DAQ Module
  • National Instruments NI-9146 Chassis
  • National Instruments PXIe-5622 Digitizer
  • National Instruments PXI-6704 Output Module
  • National Instruments 782362-01 Input Module
  • National Instruments 779068-01 Digital Module
  • National Instruments 781063-01 Output Module
  • National Instruments PCI-7356 Motion Controller
  • National Instruments 779787-01 Input Module
  • National Instruments PXIe-1071 System
  • National Instruments NI 9219 Input Module
  • National Instruments NI 9214 Thermocouple Input Module
  • National Instruments PXIe-1085 18-Slot Chassis
  • National Instruments PCIe-6320 Multifunction DAQ Card
  • National Instruments USB-6211 Multifunction I/O Device
  • National Instruments USB-6341 X Series DAQ Device
  • National Instruments NI 9205 Analog Input Module
  • National Instruments NI 9149 8-Slot Chassis
  • National Instruments PXIe-2569 Relay Module
  • National Instruments NI 9230 Sound and Vibration Module
  • National Instruments cRIO-9047 CompactRIO Controller
  • National Instruments PCI-6534 Digital IO Card
  • National Instruments PXI-5122 Digitizer Module
  • National Instruments cDAQ-9188XT Chassis
  • National Instruments cDAQ-9184 Ethernet Chassis
  • National Instruments USB-6225 OEM DAQ Device
  • National Instruments NI 9205 Input Module
  • National Instruments NI 9207 Input Module
  • National Instruments NI-9862 CAN Module
  • National Instruments 781156-01 CAN Module
  • National Instruments FP-AO-200 Output Module
  • National Instruments NI 9264 Output Module
  • National Instruments IC-3173 Controller
  • National Instruments NI 9234 Vibration Module
  • National Instruments SMB-2163 DIO Accessory
  • National Instruments PXIe-1062Q DSA System
  • National Instruments USB-6289 DAQ Device
  • National Instruments NI 9233 Vibration Module
  • National Instruments PXIe-5840 VST
  • National Instruments PXI-1033 and PXI-6132 System
  • National Instruments GPIB-USB-HS+ Controller
  • National Instruments NI 9231 Sound and Vibration Module
  • National Instruments cRIO-9074 CompactRIO Controller
  • National Instruments 782536-01 DAQ Module
  • National Instruments 779781-01 DAQ Module
  • National Instruments PXIe-8388 MXI Express Controller
  • National Instruments SCXI-1520 Strain Bridge Module
  • National Instruments PCIe-6320 Multifunction DAQ Card
  • National Instruments NI 9234 Sound and Vibration Module
  • National Instruments USB-4431 Sound and Vibration Device
  • National Instruments NI 9227 Current Input Module
  • National Instruments PXI-1033 PXI Chassis
  • National Instruments NI 9213 Thermocouple Module
  • National Instruments PXI-1042 PXI Chassis
  • National Instruments PXI-6229 DAQ Card
  • National Instruments cRIO-9075 Controller
  • National Instruments PCI-6033E DAQ Card
  • National Instruments PCIe-6363 DAQ Card
  • National Instruments cDAQ-9174 Chassis
  • National Instruments PXIe-8880 PXI Controller
  • National Instruments NI 9242 Analog Input Module
  • National Instruments USB-6221 BNC DAQ Device
  • National Instruments NI 9220 Analog Input Module
  • National Instruments cRIO-9068 CompactRIO Controller
  • National Instruments PXI-4130 Source Measure Unit
  • National Instruments USB-6251 Multifunction DAQ Device
  • National Instruments PXI-8106 Embedded Controller
  • National Instruments USB-6218 Multifunction DAQ Device
  • National Instruments PCIe-1473R Camera Link Frame Grabber
  • National Instruments PXIe-4341 DSA Module
  • National Instruments PXI-8102 Embedded Controller
  • National Instruments cDAQ-9178 Chassis
  • National Instruments USB-6210 DAQ Device
  • National Instruments USB-6212 DAQ Device
  • National Instruments NI 9485 Relay Output Module
  • National Instruments NI 9208 Current Input Module
  • National Instruments PXIe-4141 SMU
  • National Instruments PCI-6154 DAQ Card
  • National Instruments cRIO-9038 Controller
  • National Instruments PCI-6133 DAQ Card
  • National Instruments LabVIEW RIO Kit 501684G
  • National Instruments PXIe-6396 Embedded Controller
  • National Instruments USB-8502 CAN Interface Device
  • National Instruments NI 9264 Spring Terminal Output Module
  • National Instruments NI 9213 Thermocouple Input Module
  • National Instruments NI-9205 Analog Input Module
  • National Instruments NI 9264 Analog Output Module
  • National Instruments USB-6212 Multifunction I/O Module
  • National Instruments PXI-4071 FlexDMM Multimeter Module