Operation, maintenance, and troubleshooting
Maintenance Strategy
The IndraDyn H motor body is maintenance free, but preventive inspections should be performed within the overall maintenance cycle:
Measure interval
Check the cooling system function according to the overall plan, at least every 1000 operating hours
Check mechanical and electrical connections at least every 1000 operating hours
Check for smooth operation, vibration, and bearing noise at least every 1000 operating hours
Clean the motor casing, heat dissipation surface, and joint dust according to the degree of pollution, at the latest once a year
Typical faults and their handling
Excessive casing temperature: Possible reasons may include cooling system failure, changes in machining cycles, modified motor parameters, or bearing wear. Disposal includes checking/flushing the cooling circuit, reviewing the layout of the drive load, and restoring the original parameters. Special attention: After the cooling system of the liquid cooled motor fails, do not immediately restart or use low-temperature coolant - thermal shock can cause damage, wait for the motor temperature to drop to about 40 ° C before restarting.
The winding temperature reading is abnormally high but the casing temperature is normal: it is mostly due to sensor wiring errors/disconnections, diagnostic system failures, or PTC failures. The resistance of the sensor can be checked by comparing the characteristic curve with the resistance range of a multimeter (KTY84-130 should be 1000 Ω at 100 ° C).
Motor or machine tool vibration: investigate factors such as poor coupling/damage, expired bearing life, loose installation, unstable control system, etc; Damaged components must not be used again.
Position instruction not received: Common reasons include encoder cable wiring errors or misplaced pins, insufficient shielding, encoder parameter errors, loose mechanical connections, or encoder itself faults. Suggest restoring the original parameter values according to the debugging report.
Electrical testing
Electrical faults can be determined through measurement: the resistance and electrical induction between phases 1-2, 2-3, and 1-3 are consistent with each other (with an error within a specific tolerance); The insulation resistance to ground should not be less than 1 M Ω. If the difference is significant, there may be phase to phase short circuits, turn to turn faults, or ground short circuits. Bosch Rexroth customer service should be contacted.
Summary of Safety Notice Points
The safety requirements that run through the entire lifecycle include:
Risk of strong magnetic field: The rotor permanent magnet generates a strong magnetic field, and wearers of pacemakers, metal implants, and hearing aids are not allowed to enter the relevant areas; Watches, credit cards, and magnetic stripe media must be kept away from magnetic components; The ferromagnetic fixture and worktable will adsorb the rotor, and non-magnetic materials must be used;
Electrical safety: When operating live parts above 50 V, power must be disconnected; The waiting time for capacitor discharge is at least 30 minutes; Electric drives must not use residual current protection devices (RCD) and must use overcurrent protection devices to prevent indirect contact;
Dangerous motion protection: Parameter input errors, wiring errors, software failures, etc. can all lead to accidental movements; The vertical axis must be equipped with mechanical locking, external braking/holding brakes, or balancing measures - standard motor holding brakes or driver direct control holding brakes are not sufficient to ensure personal safety;
Hot set operation: Both 135-145 ° C hot rotor and -20 ° C cold spindle require heat-resistant/antifreeze protective equipment;
Hydraulic operation: Only manual oil pump is allowed for dismantling the 2N rotor (ensuring that the pressure immediately returns to zero in case of leakage), and a safety valve is installed to prevent the oil pressure from exceeding 1500 bar.