Coolant requirements
All technical data is cooled by water, and data must be recalculated when using other media;
Prohibit the use of hard tap water (which is prone to scaling and damaging the motor and cooling system);
Anti corrosion additives that are compatible with the mixed installation of copper (cooling pipelines) and brass (joints) must be added;
Recommend using a closed-loop circuit and configuring a 100 μ m fine filter;
Prohibit the use of cutting lubricants generated during machining as cooling media;
Avoid contamination of the cooling medium and drift of chemical composition and pH value.
The setting of the coolant inlet temperature should be combined with the ambient temperature to prevent condensation: the minimum temperature that can be set should not be lower than 5 ° C below the ambient temperature. For example, when the ambient temperature is 20 ° C, the inlet temperature should be set at+15...+40 ° C.
Cooling circuit calculation
Flow rate: Q=Pco × 60000/(c ·ρ·Δ T), determined based on power loss corresponding to rated torque and 10 K temperature rise;
Pressure drop: Δ p=p1 − p2, which increases nonlinearly with the increase of flow rate. The total pressure drop of the system is composed of the pressure drops of various components such as motors, pipelines, and joints, which must be taken into account when selecting pumps;
Non aqueous medium torque reduction: kcred=√ (cx ·ρ x/(cw ·ρ w)) × 100%. If using heat transfer oil (c=1000 J/kg · K, ρ=887 kg/m ³), the torque availability relative to water will significantly decrease.
Series parallel connection of cooling system
Parallel connection: Each component can be cooled according to its own required flow rate, with consistent inlet temperature and pressure difference, and high thermal operation reliability - preferred for multi-component systems;
Series connection: When the same flow passes through all components, the accumulated pressure drop leads to an increase in system pressure, and the inlet temperature of downstream components gradually rises, resulting in uneven heating of the machine; Only applicable when the flow demand is similar, the pressure drop is small, or far away from the cold source;
The combination of serial and parallel can take into account the advantages of both methods.
Thermal removal equipment is divided into three categories: gas-liquid cooling units (temperature control accuracy ± 5K, suitable for independent machine tools without upstream cooling circuits), liquid-liquid cooling units (± 5K, suitable for systems with existing central feedback coolers), and refrigeration cooling units (± 1K, suitable for high-precision machining and other situations that require high thermal stability). Flow, pressure, and temperature monitoring systems should be installed in the cooling circuit.
Debugging process and key parameters
Due to the lack of parameter memory for frameless motors, all motor parameters must be manually entered or loaded during debugging (DriveTop debugging software can provide all Bosch Rexroth motor parameters). The core Sercos parameters include: pole number (P-0-0018), torque constant (P-0-0051), d/q-axis inductance (P-0-4016/4017), stator resistance (P-0-4048), encoder resolution (S-0-0116), etc. After inputting the motor parameters, it is not possible to immediately power on - the encoder parameter input, encoder polarity check, and commutation adjustment need to be completed first.
Encoder polarity
The effective direction of motor torque must be consistent with the counting direction of the encoder, otherwise uncontrolled motion will occur when powered on. Select polarity through S-0-0277 (position encoder type 1, Bit 3), and set all zeros for S-0-0085 (torque polarity), S-0-0043 (speed polarity), and S-0-0055 (position polarity). After setting, it must be verified that the encoder outputs a positive signal when the motor rotates clockwise.
Reversing adjustment
Reversing adjustment is the process of establishing a reference for the relative position of the rotor to the stator, ensuring that the stator current vector and rotor magnetic flux vector always maintain a 90 ° angle, thereby outputting the maximum constant torque. The following situations must be executed: debugging startup, change of mechanical connection method of encoder, replacement of encoder, change of mechanical connection of stator or rotor. Absolute encoders (such as Rexroth DSF/HSF) only need to perform one commutation adjustment during initial debugging; The incremental encoder needs to be executed every time it is powered on.
Control loop tuning
Debugging is carried out in the cascade order of "current loop (with motor parameters) → speed loop optimization → position loop optimization → acceleration feedforward". If there is mechanical resonance ("double mass oscillation" often occurs between 400-800 Hz), it can be selectively suppressed through a rejection filter: the attenuation is deepest at the notch frequency, and the bandwidth determines the attenuation range - the larger the bandwidth, the shallower the attenuation at the notch frequency. After suppressing mechanical resonance, the dynamic performance of the velocity and position loops can be further improved, resulting in higher contour accuracy and shorter positioning cycles.