Dangerous motion protection: Incorrect wiring, misoperation, sensor/encoder failure, component defects, or software errors can all cause dangerous motion - it can occur immediately after power on or after a period of trouble free operation. Upper level monitoring or measures must be set up above the device; The emergency stop switch must be installed within easy reach of the operator and verified before starting; Isolate the driving power supply through emergency stop circuit or start suppression system; After the vertical axis is powered off, it is necessary to prevent falling - mechanical locking, external brake/clamping mechanism, or counterweight balance can all be used, but standard motor brake or servo driven direct control external brake are not sufficient to ensure personnel safety.
Other protections: wearers of pacemakers, metal implants, and hearing aids are not allowed to enter the storage, operation, and maintenance areas of motor permanent magnets; Wait for 10 minutes for cooling before touching high-temperature components; Batteries are strictly prohibited from being heated, reactivated, charged, ignited, or disassembled. As hazardous materials, they must be disposed of separately according to legal requirements (explosion risk, applicable to land, sea, and air transportation); The pressurized system (compressed air, hydraulic oil, coolant) must be depressurized and drained before disassembly.

Front panel and keyboard system
Soft drive cover and reset button: A reset button (accessible with a fine object such as a ballpoint pen) and an external keyboard connector are located below the soft drive cover. When there is no PCK03 external keyboard, this connector can be used as a service interface. Pressing the reset button will terminate all open applications without saving and restart the computer. During the operation of the floppy drive, the cover plate must be kept open. Closing the cover plate may cause read and write errors.
Status display: There are three LEDs under the cover plate: TEMP (temperature monitoring), POWER (always on when powered on), and HDD (lights up when accessing the hard drive).
Button system:
Function keys (F2-F9) and operation keys (OP2-OP9): The second function of the dual function key needs to be activated by pressing the "up arrow" (Shift) key simultaneously; The OP key line can also be configured with an insert tab bar;
PC keyboard simulation: OP2 → OP9 corresponds to CTRL+SHIFT+ALT+F2 → F9, PROG corresponds to CTRL+SHIFT+ALT+Q, NEXT corresponds to CTRL+SHIFT+ALT+N, INFO corresponds to CTRL+SHIFT+ALT+I, Menu corresponds to ALT, Change windows corresponds to CTRL+F6, Grass window corresponds to CTRL+F7, Maximize in cursor center corresponds to CTRL+SHIFT+ALT+M;
Machine function keys (L1-L8 on the left, R1-R8 on the right): used as direct hard wired inputs in PLC, addressing by absolute address (L1=% I0.1480.0 to L8=% I0.1480.7, R1=% I0.1481.0 to R8=% I0.1481.7), used to start configured PLC or CNC movements; It can also be addressed with address constants MFT-L (A # iMFK-L) and MFT-R (A # iMFK-R). PLC program example: MFT.L.L1;
PLC function keys (S1-S14, with LED) and key switch (Operator/Prog): illuminated pluggable label keys, connected to the PLC together with the key switch, replacing standard switch components that fix PLC functions (such as "return to reference point" or "end of cycle shutdown"); Key addresses% I *. 0.0 to% I *. 1.7, LED addresses% Q *. 0.0 to% Q *. 1.7, two free logical addresses must be allocated in the PLC configuration.
Insert label replacement: 14 PLC function keys and OP key rows can be replaced. Insert labels - cut by line, pinch the right end and slide it in. The labels must be inserted into the foil bag attached to the front panel (otherwise only the first baffle can be inserted). After sliding to the bottom, check the fit between the button and the label. If it is not suitable, cut it short and reinsert it from the right side. The remaining part can be cut but the possibility of replacement must be retained.
Keyboard language: Adjust the external keyboard in the Windows NT control panel (Keyboard → Input localities); The built-in embossed keyboard needs to be set through the "BTV20" icon on the control panel (in American English/German/British English/Italian/Spanish). If the icon does not exist, the SWD-BTV20 * - UTI-01VRS tool disk needs to be installed. The selected language must be consistent with the external keyboard settings in the operating system.
Quick Overview of Technical Data
Project specifications
Processor Pentium Slot CPU with a minimum frequency of 300 MHz, integrated graphics controller
Main memory/hard disk 64 MB/minimum 3 GB
Interface 1: Serial RS232, 1: Parallel Centronics, 1: Indramat RS232/422/485
Display 10.4 "TFT color
Slot 3 x PCI, 1 x PCI/ISA, 4 x ISA
Keyboard machine operation keyboard, 16 machine function keys
Protection front IP65, chassis IP20 (DIN 40 050, IEC 529)
Panel color RAL 7035 light gray
Dimensions (rear shell/including panel) 372 × 335 × 209/407 × 370 × 220 mm (B × H × T)
Power supply 115/230 VAC ± 15% automatic switching, maximum 250 VA