Typical heat dissipation of 100 W/maximum of 200 W
Weight approximately 10.5 kg
Power supply unit: Input range 90... 132/180... 264 VAC, 47... 63 Hz; Input current 4.2 A @ 115 V/2.0 A @ 230 V; Surge current 35/70 A; output+5 V (5... 20 A,+5%/-4%), -5 V,+12 V (2... 8 A), -12 V; Maximum output of 200 W, efficiency of 70% @ 230 V/200 W; Working temperature: 0... 45 ° C @ 200 W/0... 55 ° C @ 100 W.
Environmental conditions: Operating temperature+5 ° C to+45 ° C (storage/transportation -20 ° C to+60 ° C); Temperature change rate 10 K/h (15 K/h); Relative humidity of 75% average/80% occasional (storage without condensation, DIN 40 040 F level); Air pressure 860-1060 hPa to 1500 m; maximum external magnetic field 6 × 10 ⁻⁴ Tesla; Vibration (without FDD access) 5-55 Hz ± 0.0375 mm sine three-axis, 55-500 Hz 0.5g; Impact 15g/11ms half sine (storing 30g).
Vulnerable parts (not covered by warranty): fan, backlight tube, floppy disk drive, hard disk, Slot CPU battery. The average life expectancy is 5 years or 20000 operating hours. The HDD lifespan specifications are based on: 40 read/write cycles/day x 200 days/year, 10 ⁵ seek cycles/day x 200 days/year, 14 h/day power supply, 8 h/day read/write, and no vibration or impact in an environment of 25 ° C/50% RH/100kPa.
Size and Installation
The panel opening size is 373 × 336 mm; the installation adopts a front installation method: 10 × sealed M5 × 16 bolts pass through the panel, and are fixed to the installation panel with 10 × M5 combination nuts, locking washers, and flat sealing rings. At least 20 mm gap must be left between the rear and sides for air circulation; The connector space requirement is about 100mm.
Detailed explanation of connections and interfaces
Power supply and grounding: 115/230 VAC ± 15% automatic switching, P–250 VA,50/60 Hz; Connect the minimum 6 mm ² grounding terminal to the central grounding terminal.
Slot CPU interface: serial port COM1(Pin1 DCD、2 RxD、3 TxD、4 DTR、5 GND、6 DSR、7 RTS、8 CTS、9 N.C.)——CPU The board is driven by a capacitive charge pump RS232 and only powered by 5V; Due to COM1's RS232/RS422/RS485 multifunctional capability, RI (ring indicator) signal is not supported and is used as output in RS232 mode. Do not connect any signal. SVGA screen connection and Ethernet 10Base-T (Pin1 TxD+, 2 TxD -, 3 RxD+, 6 RxD -) are complete.
LPT1 and SIS: The two interfaces are directly connected to Slot CPU via printed circuit board PSU02; COM2 (X16) is wired according to Indramat standard (SIS) and supports RS485/RS232/RS422; LPT1 has standard Centronics pins. The GPIO configuration of PSU02 is determined by BIOS settings (Inside Utilities), and the output level combination of General Purpose IO 1/4/6 determines the RS485 (Auto/Input/RTS-Control//RTS Control) and RS422 (Off/Auto/Output/Input/RTS-Control) functions - the factory default is the Output (high) x 3 combination.
BIB05 card insertion (PC version): The PC variant (with the 4th digit of the function type code being "P") only includes a CPU module and no controller. Equipped with a BIB05 card, the machine's function keys and key switches can be accessed via Interbus and ISA buses. BIB05 is a short 8-bit PC card: 8 consecutive I/O addresses are allocated on the ISA bus (configurable base addresses 0000h-03C0h), and the rotary encoding switch selects the base address (factory base address 140h is the 'A' bit); The two bus systems can independently read all keys simultaneously, but only one bus system can write the S1-S14 keys and key switch LED. The three position sliding switch selects write access (1-way circuit=ISA, middle=disabled, 2-way slot board=Interbus), and the factory configuration is "Interbus write access"; ID-COde 03h (digital device with input/output data), with a data width of 2 words. ISA address mapping: Base+0=S8... S1, Base+1='Prog' key switch/'Operator' key switch/S14... S9, Base+2=R8... R1, Base+3=L8... L1, Base+4/5=LED - buttons L1-L8, R1-R8, S1-S14 and the key switch are indicated by '1' for corresponding contact closure. Interbus side PLC function key address% I *. 4.0-% I *. 5.7, machine function keys L1-L8=% I *. 7.0-. 7, R1-R8=% I *. 6.0-. 7.
INTERBUS connection (X65 out/X66 in): X65 includes DO/DI, GND,+5V, RBST (9-pin); X66 is for DO1/DI1 data entry and exit.

Application examples
MTS-P+INTERBUS: The MTS-P X60 of BTV20 is connected to RECOM12 (RMK12.1-IBS-BKL module) via IKS 0056 INTERBUS-S cable, with Remote Bus Interconnect supporting more INTERBUS-S devices, supplying power from 3 × 0.75 mm ² to+24 VDC;
BTA10/20 and BTC06: MTS-P0x. 2 (marked as 2D in the configuration code) and Fast PLC (marked as 2F) have integrated a 15 pin Indramat standard interface in their slots, connected to BTA20 via IKB0015 cable; Up to 6 BTA10s can be operated, and only one BTC06 can be operated at a time. The key switch activates the interface on the BTA module; Only RS422 communication is available between units (IKB0015 has a maximum RS422 length of 400 meters);
SIO extension: By configuring code S4 (such as CFG BTV20.3E-NN-2T-NN-BB-S4-B1-2D-2E-NN), two additional interface slots can be connected to BTA10 through SIO on the printed circuit board using IKB0016;