2. Multi circle limit setting
Parameter: Pn205 (multi turn limit value), set as the number of rotations of the load axis -1
Effective: After modification, Fn013 (multi turn limit reset) must be executed, otherwise A.CC0 alarm will be triggered
Maintenance and troubleshooting
(1) Regular maintenance system
1. Daily maintenance (daily)
Appearance inspection: The cable is free of wear, looseness, oil and water stains
Operating status: No abnormal vibration or noise, motor temperature ≤ 60 ℃
Indicator light: No alarm light on, CHARGE light will turn off within ≤ 5 minutes after power failure
2. Annual maintenance
Insulation testing: Disconnect the servo amplifier and measure the resistance between the motor U/V/W and FG using a 500VDC insulation resistance meter. A resistance of ≥ 10M Ω is considered normal
Gap calibration: Use a non-magnetic feeler gauge to measure the gap between the rotor and the magnetic track. If the deviation exceeds 0.5mm, it needs to be adjusted
Cable inspection: The shielding layer is not damaged, the joints are firm, and there is no aging at the bends
3. Overhaul cycle (every 5 years)
Component replacement: cooling fan, aluminum electrolytic capacitor, cable (frequent bending scenario)
Comprehensive testing: winding insulation, magnetic track magnetism, sensor calibration (contact YASKAWA technical personnel)
(2) Common faults and solutions
Alarm code, fault name, possible cause, and solution
A. 830 absolute encoder battery fault, low battery voltage, poor battery contact. Replace the battery, check the battery wiring, restart and clear
A. 9A0 over travel warning limit switch triggered, P-OT/N-OT signal wiring error checked limit switch status, verified signal wiring, sent ALM_CLR to clear
A. F10 main circuit phase loss power supply wiring loose, single-phase/three-phase setting error check power supply wiring, confirm Pn00B. 2 setting matches power supply type
A. Insufficient capacity of 320 regeneration overload regeneration resistor, frequent replacement of larger capacity regeneration resistor for braking, and prolonged deceleration time
A. Eb1 safety function signal timing error HWBB signal single input, signal delay exceeding 10 seconds. Check HWBB dual wiring to eliminate signal interference
(3) Principles of troubleshooting
Power off before troubleshooting: Do not measure live signals, operate only after the CHARGE light is turned off
Mechanical first, electrical later: prioritize checking mechanical clearances and fixing screws, then checking wiring and parameters
Basic first, then complex: first confirm power supply, grounding, and wiring, then investigate parameters and communication
Compliance and environmental requirements
(1) Compliance standards
North America: UL 508C, UL 1004-1, CSA C22.2 No.100, branch circuits require specified semiconductor fuses
EU: CE certification (EMC Directive 2014/30/EU, LVD Directive 2014/35/EU), compliant with EN 61800-3 (C2 environment)
UK: UKCA certification, compliant with Supply of Machinery (Safety) Regulations, etc
China: Energy Efficiency Labeling for Permanent Magnet Synchronous Motors (CEL 038-2020, GB 30253-2013)
(2) Environmental Protection and Scrapping
Environmental requirements: RoHS Directive 2011/65/EU, restricting six harmful substances including lead and mercury
Scrap disposal:
Demagnetization treatment: Heat the magnetic track to above 300 ℃ and maintain it for 1 hour to eliminate magnetism
Classification and recycling: Separate electronic components (windings, sensors), metal components (magnetic tracks, shells), plastic components
Prohibited from littering: Dispose of by professional environmental organizations in accordance with the WEEE directive