Cable and plug: No damage or aging, and the plug has good contact.
Run every 8 hours (or after each use)
Oil level check: Add oil to the standard level (not exceeding the "H" mark).
Fuel filter inspection: Observe whether there is moisture or impurities in the sedimentation cup. If there are, unscrew the drain screw to drain it, and then tighten it again.
3. Long term storage and maintenance (over 3 months)
Preparation before storage:
Cleaning: Thoroughly wipe off dust and oil stains on the surface of the body, clean up debris from the heat sink and ventilation vents.
Fuel treatment:
Method 1 (Adding Stabilizer): Fill up with fresh fuel, add fuel stabilizer (according to the instructions), start the engine and run for 5 minutes, let the stabilizer circulate to the fuel system, and close the fuel valve and battery switch.
Method 2 (Drain Fuel): Close the fuel valve, unscrew the carburetor float drain screw, and drain the fuel; Unscrew the fuel tank drain screw, drain the fuel from the tank, and then tighten all screws.
Oil change: Change the engine oil according to the procedure (to avoid impurities in the old oil corroding the engine).
Cylinder rust prevention: Remove the spark plug, inject 1 teaspoon of new engine oil into the cylinder, pull the starting rope 3-5 times (without ignition) to evenly distribute the engine oil on the cylinder wall, then reinstall the spark plug and pull the starting rope until the piston is in compression stroke (valve closed to prevent moisture from entering).
Battery handling: Disconnect the battery, store it separately after fully charging, and recharge it every 1-2 months (to avoid battery depletion).
After storage, remove and use:
Remove the dust cover and check the appearance of the generator for any damage or debris.
Connect the battery and check the oil level (replenish if insufficient).
Add fresh fuel (do not use fuel that has been stored for too long).
According to the normal start-up process, the engine may emit smoke for a short period of time (residual oil in the cylinder), which is a normal phenomenon and will disappear after running for 1 minute.
4. Maintain taboos and precautions
Do not use flammable solvents such as fuel or banana oil to clean components (such as air filters and machine bodies) to avoid causing fires.
It is prohibited to mix different brands and models of engine oil, and it is forbidden to use two-stroke engine oil or inferior engine oil (which can damage the engine).
When replacing spark plugs, the recommended model must be used and the tightening torque should not be too high (to avoid damaging the cylinder head threads).
When cleaning the air filter, do not twist or tear the foam filter element, and do not wash the paper primary filter with water (only air blowing).
After all maintenance operations, it is necessary to ensure that the components are securely installed and the screws are tightened to avoid detachment during operation.

Deep troubleshooting of common faults (including causes and solutions)
Possible causes of malfunction, troubleshooting steps, and solutions
Unable to start: 1. Battery depletion (electric start/remote start failure); 2. Insufficient or deteriorated fuel; 3. Spark plug malfunction (carbon buildup, improper clearance, moisture); 4. The fuel valve is not open; 5. Air filter blockage; 6. Incorrect position of the air door (manual start); 7. CO sensor triggering protection: 1. Check the battery voltage (≥ 12V), and charge or replace it if it is low on power; 2. Check the fuel gauge and add fresh fuel; 3. Remove the spark plug and check its condition; 4. Confirm that the fuel valve is in the "ON" position; 5. Check if the air filter is clogged; 6. The air door of the refrigeration unit needs to be closed, and the heating unit needs to be opened; 7. Transfer to a ventilated area and wait for 10 minutes before restarting. 1. Charge or replace the battery; 2. Replace with fresh fuel; 3. Clean spark plugs, adjust clearances, air dry if damp, replace if damaged; 4. Open the fuel valve; 5. Clean or replace the air filter; 6. Adjust the position of the air door; 7. If restarting after ventilation is still ineffective, contact after-sales service
Stop immediately after startup. 1. Low oil protection (insufficient engine oil); 2. Fuel pipeline blockage; 3. The load is not disconnected; 4. Excessive concentration of CO; 5. Overheating protection (engine temperature too high) 1. Check if the low oil warning light is on and replenish the engine oil; 2. Check for blockages in the fuel filter and fuel pipes; 3. Confirm that all loads have been disconnected; 4. Transfer to a ventilated area; 5. Check if the heat sink is blocked and if the ambient temperature is too high. 1. Add engine oil to the standard level; 2. Clean the fuel filter and unclog the fuel pipe; 3. Restart after disconnecting the load; 4. Restart after ventilation; 5. Clean the heat sink and move it to a cool place for operation
Insufficient power/unstable speed during operation 1. Load exceeding the standard; 2. Insufficient fuel supply (clogged fuel filter, leaking fuel pipe); 3. Air filter blockage; 4. Spark plug carbon deposition; 5. Blockage of carburetor; 6. Ignition coil fault: 1. Check if the total load exceeds 9500W; 2. Check if there are impurities in the fuel filter and if the fuel pipe is leaking; 3. Check the status of the air filter; 4. Clean the spark plug; 5. Check if the carburetor is clogged; 6. Test the ignition coil output. 1. Reduce the load to the rated range; 2. Clean the fuel filter and repair the leaking oil pipe; 3. Clean or replace the air filter; 4. Clean or replace spark plugs; 5. Disassemble and clean the carburetor (professional operation); 6. Replace the ignition coil