After starting the engine, slowly return the handle (to avoid rebounding and hitting the body) and gradually open the air door (pull out).
Hot engine start: If the engine has been preheated, there is no need to close the air door, simply pull the start rope.
(4) Stable process after startup
Run without load for 3-5 minutes, allow the engine and generator to fully warm up, observe the data center: voltage 230-250V, frequency 58-62Hz, no fault indicator light on (CO alarm light, low fuel alarm light, etc. are all off).
Check engine sound: The sound is uniform during normal operation and there is no abnormal noise (such as knocking or whistling); If there is any abnormal noise, stop the machine immediately for inspection.
Load connection: According to the principle of "high power first, low power later", connect the devices one by one, ensuring that the plug is fully inserted during connection to avoid loosening and heating.
3. Monitoring and regulation during operation
Real time monitoring points:
Data center: Regularly check voltage, frequency (fluctuation range should not be too large), and cumulative operating time (remind maintenance cycle).
Indicator lights: CO alarm light, low oil alarm light, overheating alarm light, overload alarm light should all be turned off. If they are turned on, follow the fault handling process.
Fuel gauge: Observe the remaining fuel level and replenish it in a timely manner (to avoid shutting down due to running out of fuel).
Adjustment operation:
If the overload alarm (circuit breaker tripping) is caused by excessive load, immediately disconnect part of the load, press the circuit breaker reset button, and then reconnect.
If the engine speed fluctuates during operation, it may be due to insufficient fuel supply or clogged air filter. Check if the fuel valve is fully open and if the air filter is clean.
Long term operation (exceeding 2 hours) requires regular checks of engine temperature (with no abnormal overheating on the side of the body) to ensure good heat dissipation.
4. Shutdown process (operating in different scenarios)
(1) Normal shutdown
Disconnect all loads (unplug or turn off the device switch).
Run the generator without load for 3-5 minutes to cool down the engine and generator (to avoid direct shutdown due to high temperatures causing carbon buildup).
Press the "START/STOP" button on the control panel for 1 second or the "STOP" button on the remote control to shut down the engine.
Turn off the battery switch (OFF) and fuel valve (OFF).
Close all waterproof covers of sockets and cover with dust covers (if not used for a short period of time).
(2) Emergency shutdown (fire, leakage, abnormal noise, etc.)
Press and hold the "START/STOP" button on the control panel for 3 seconds to force a shutdown (without disconnecting the load).
Follow up processing: Investigate the cause of the malfunction (such as fuel leakage, engine noise), eliminate the fault before use, and prohibit restarting without troubleshooting.
(3) Long term shutdown (exceeding 1 month)
Disconnect the load according to the normal shutdown process and run it without load for 1 minute.
Close the fuel valve and allow the engine to continue running until the fuel runs out and automatically shuts down (to avoid fuel deterioration and blockage in the carburetor).
Disconnect the battery connection (unplug the quick connector), fully charge the battery and store it separately (to avoid damage due to low battery).
Clean the dust and oil stains on the surface of the generator, check the condition of the air filter and spark plug, and clean them if necessary.
Inject 1 teaspoon of new engine oil into the cylinder and pull the starting rope 3-5 times (without ignition) to evenly distribute the oil on the cylinder wall (rust prevention).
Cover with a dust cover and store in a dry, ventilated, and cool room (do not store in flammable areas).
Complete maintenance process (including cycle and details)
1. Preparation before maintenance
Safety measures: Turn off the generator, disconnect the battery connection, and allow the engine to cool to room temperature (to avoid high-temperature burns); Operate in a well ventilated area and prepare tools (wrench, oil pan, funnel, wire brush, etc.).
Tool list: Phillips/Phillips screwdriver, spark plug socket wrench, oil pan, funnel, cleaning cloth, compressed air (optional), new oil, fuel stabilizer, spark plug (spare), air filter cleaning fluid.
2. Routine maintenance items (executed on a periodic basis)
Before/after each use
Cleaning: Use a dry cloth to wipe the dust and oil stains on the surface of the machine body, clean the debris on the heat sink and ventilation openings (to avoid blockage that affects heat dissipation); Check if the waterproof cover of the socket is intact.
Check:
Appearance: The components are not loose or damaged, and the oil pipes and oil pipe joints are not leaking.
Oil level: The engine oil level is between "L" and "H", the fuel gauge shows sufficient, and there is no leakage.
Battery: The connection is firm, without bulging or leakage (lead-acid batteries need to check the electrolyte level, and if it is insufficient, add distilled water).
Email:wang@kongjiangauto.com