Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

Westinghouse WH7500V portable generator

F: | Au:FAN | DA:2025-11-13 | 699 Br: | 🔊 点击朗读正文 ❚❚ | Share:

Westinghouse WH7500V portable generator

Detailed explanation of core product information

1. In depth analysis of technical parameters

Category parameter details note explanation

Power performance: Continuous power 6000W, peak power 7500W, voltage 120/240V single-phase, frequency 60Hz. Peak power is only used to start inductive loads (such as motor equipment), and continuous operation requires ≤ 6000W

The engine system is a four stroke single cylinder OHV engine with a cylinder diameter of 66 × 90mm and an ignition method of TCI (transistor ignition). The OHV design improves combustion efficiency and extends engine life; Forced air cooling for heat dissipation, suitable for long-term operation

Oil specifications: Oil capacity 1.1 liters, recommended models: SAE 10W-30 (normal temperature -10~40 ℃), 5W-30 (low temperature<-10 ℃), SAE 30 (high temperature>30 ℃). API SJ or higher grade four stroke engine oil is required, and the use of two-stroke engine oil or mixed engine oil is strictly prohibited

The fuel tank capacity of the fuel system is 25 liters (6.6 gallons), suitable for unleaded gasoline of grade 87 and above. E15/E85 ethanol gasoline is prohibited if the ethanol content is ≤ 10% (which can easily cause corrosion and blockage of the fuel system); 50% load can run for more than 10 hours under full oil condition

Starting method: Electric start (12V lead-acid battery), manual manual start (emergency backup). Electric start requires sufficient battery power, and manual start is an emergency plan suitable for battery depletion scenarios

The physical characteristics are equipped with universal wheels and a telescopic single handle. The body is made of steel frame, and the bottom is equipped with shock-absorbing pads for easy short distance movement by a single person. The shock-absorbing pads reduce vibration during operation; The net weight is relatively heavy (about 100kg), and long-distance transportation requires the cooperation of two people or mechanical assistance

Safety protection includes low fuel automatic shutdown, GFCI leakage protection, circuit overload protection, spark suppressor, and fuel shut-off valve to comprehensively avoid operational risks. The spark suppressor prevents sparks from leaking out of the muffler and is suitable for outdoor dry environments

2. Analysis of core components and control panel

(1) Core component functions

Engine compartment: Built in four stroke OHV engine, including air filter, spark plug, muffler (with spark suppressor), oil filling port/dipstick, oil drain bolt, engine block with heat sink to enhance heat dissipation.

Fuel system: large capacity fuel tank (with fuel gauge), fuel shut-off valve (controlling fuel supply on/off), fuel filter (sedimentation cup type, filtering impurities), carburetor (atomizing fuel).

Power generation system: AC generator (with AVR voltage regulator, stable output), equipped with main circuit breaker and branch circuit breaker to prevent overload and short circuit.

Mobile and Fixed Components: Universal Wheels (Wear resistant and Anti slip), Telescopic Handle (Rubber Anti slip Grip), Bottom Support Feet (Enhance Placement Stability), Shock Absorbers (Reduce Operating Vibration).

(2) Control panel full analysis

Component Name Function Description Operation Points

The electric start switch (START/RUN/STOP) integrates the functions of starting, running, and stopping. Press "START" for 1 second to start, keep "RUN" for running, and set "STOP" for stopping

The hour meter records the cumulative operating time of the generator to remind maintenance intervals (such as 50 hours of oil change), and only counts under load conditions

Two 120V 20A GFCI dual socket outlets output 120V AC power with leakage protection. The maximum load of a single socket is 2400W, and the total load of the dual sockets is ≤ 4800W. After use, close the waterproof cover plate

120/240V 30A locking socket (1) outputs mixed voltage, suitable for high-power equipment (such as air conditioning, water pump) with a maximum load of 7200W (240V) or 3600W (120V), requiring the use of a dedicated L14-30R locking plug

Circuit breaker (20A/25A) 20A corresponds to a 120V socket, 25A corresponds to a 240V socket, and automatically trips when overloaded/short circuited. Before resetting, the fault needs to be investigated (such as reducing the load and repairing the short circuit)

The grounding terminal is used for external grounding (such as when connected to a household power distribution system). The neutral wire is already connected to the body and does not require additional grounding when used separately; Grid connection must be grounded according to regulations

The fuel gauge visually displays the remaining fuel level in the fuel tank. When the fuel level is less than 1/4, it should be replenished in a timely manner to avoid running out of fuel and shutting down during operation

image.png

Safety operation standards (including risk avoidance)

1. Environment and placement safety

Core requirements for placement:

Only use in fully open and well ventilated outdoor areas, at least 6 feet (about 1.8 meters) away from doors, windows, ventilation openings, tents, etc., to prevent carbon monoxide exhaust from entering indoors (the engine exhaust contains highly toxic carbon monoxide, which is colorless and odorless).

  • Basler D90 96801 100 PCB Card
  • Basler XR2002F Voltage Regulator (110 VAC, 48-480 Hz)
  • Basler SR8A-2B14B3A Regulator
  • Basler 9561500100 Module
  • Basler DECS-400 BE1-11 System
  • Basler DECS-100-B15 Excitation Control
  • Basler SCP 210 Frequency Controller
  • Basler SR4A-2B15B3A Static Voltage Regulator
  • Basler BE1-32R Power Relay
  • Basler PIA2400-17GM Power Interface Adapter
  • Basler MVC 232 Manual Voltage Control Module
  • Basler SSR 32-12 Static Voltage Regulator
  • Basler 5MW AVR Generator Voltage Regulator
  • Basler VR63-4B Voltage Regulator
  • Basler DECS-100-A05 AVR for Engine Generator
  • Basler DECS-100-B15 Automatic Voltage Regulator
  • Basler BE1-32R Directional Power Relay
  • Basler BE1-87B Differential Relay
  • Basler UFOV 260A Protective Module
  • Basler 9-2614-02-100 PCB Rev M
  • Basler DECS-100-B15 Digital AVR
  • Basler 9284900103 PS DECS-400N
  • Basler D4N3H1U Intertie Protection
  • Basler DECS-100-B15 A15 AVR
  • Basler KR4F Voltage Regulator
  • Basler BE26434 T14 Transformer
  • Basler SR8A-2B15B3A Regulator
  • Westinghouse 774B472A12 AR Relay
  • Basler DECS-100-B15 AVR
  • Basler XR2002F Regulator 110V
  • Basler SR125-E Static Regulator
  • Basler SSR 125-12 Regulator
  • Basler MOC2599 Motor Pot
  • Basler BE1-DFPR Feeder Relay
  • Basler CBS 305 Current Boost
  • Basler BE1-25 AutoSync
  • Basler MVC 300 Voltage Control
  • Basler BE3-25A AutoSync
  • Basler KR7FF Static Regulator
  • Basler 90-49000-100 Regulator
  • Basler 880 kVA Dry Type Transformer Specs
  • Basler Electric BE1-25 Sync-Check Relay Specs
  • Basler SSR 125-12 Voltage Regulator Specs
  • Basler Electric BE1-851 Overcurrent Relay Review
  • Basler Electric 149D930G02 Control Sub-Assembly
  • Basler Electric BE1-81O/UT Frequency Relay Specs
  • Basler Electric BE1-51/27C Overcurrent Relay
  • Basler Electric 149D956G02 Industrial Component
  • Basler Electric BE1-51A Overcurrent Relay Specs
  • Basler Electric BE1-40Q Loss of Excitation Relay
  • Basler DECS-200 Excitation Control System
  • Basler DECS-200 Voltage Regulator 56-277V AC / 125V DC
  • Basler BE1-87T Transformer Differential Relay
  • Basler RDP-110-S1 Protection Relay
  • Basler BE1-700V Digital Protective Relay
  • Basler BE1-951 Overcurrent Protection System
  • Basler DECS-300 Digital Excitation Control
  • Basler DECS-200 Digital Excitation Control
  • Basler DECS-200-1C Excitation Control System
  • Basler DECS-200-1L Digital Excitation Control
  • Basler Electric BE1-GPS Generator Protection System
  • Basler Electric DECS-200-1C Digital Excitation Controller
  • Basler Electric DECS125-15 Excitation Control with Power Module
  • Basler Electric BE1-87G Differential Relay
  • Basler Electric BE1-11 Protection System I5A3M2P2N0EA00
  • Basler Electric DECS-200-1C Excitation Control System
  • Basler Electric BE1-11g Generator Protection Relay
  • Basler Electric DECS 125-15-B2C1 V2.0.9 Excitation Control
  • Basler Electric BE1-81O/UT3ED1JA7N2F Frequency Relay
  • Basler Electric BE1-81O/UT3EE1YB7N1F Frequency Relay
  • Basler Electric DECS-200-1L Digital Excitation Control System
  • Basler DECS125-15-B2C1 Excitation Control
  • Basler 9507900205 SSR Retrofit Voltage Regulator
  • Basler BE2000E Digital Voltage Regulator
  • Basler BE1-GPS Generator Protection System
  • Basler DECS-250-CN1CN1N Digital Excitation Control
  • Basler DGC-2020 Genset Controller
  • Basler BE1-81O UT3ED1LA7N0F Frequency Relay (Variant)
  • Basler BE1-81O UT3EE1YA9S0F Frequency Relay (Variant)
  • Basler BE1-81O Over/Under Frequency Relay
  • Basler DECS125-15 Digital Excitation Control
  • Basler Electric BE1-951 Overcurrent Protection System
  • Basler Electric BE1-700V Digital Protective Relay
  • Basler Electric APR63-5 Automatic Voltage Regulator
  • Basler Electric BE1-851 Overcurrent Protection System
  • Basler Electric DECS-250-LN1SN1N Excitation Control
  • Basler Electric BE1-87T Transformer Differential Relay
  • Basler Electric DECS-200-1L Excitation Control System
  • Basler Electric 9310300100 DECS-300 Excitation Control
  • Basler Electric SSE-N 125-4.5KW Shunt Exciter Regulator
  • Basler Electric DGC-2020HD-5NS1DNSBA Genset Controller
  • Basler Electric BE1-81-O/UT3EE1JB7N1F Frequency Relay
  • Basler Electric BE1-81T1EE1WA0N1F Frequency Relay
  • Basler Electric BE1-25M1EA6PN5R1F Sync-Check Relay
  • Basler Electric BE1-GPS Generator Protection System
  • Basler Electric DECS-250-LN1SN1N Excitation Control Rev V
  • Basler Electric DECS-250-CN2CN1N Excitation Control
  • Basler Electric BE1-50/51B-207 Overcurrent Relay
  • Basler Electric DECS-300-C0N0 Excitation Control System
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric DECS-250-LN1CN1N Excitation Unit
  • Basler Electric DECS-250 LN2SA1D Excitation Unit Specs
  • Basler Electric BE1-87T Transformer Relay Review
  • Basler Electric BE1-11 Protection System
  • Basler Electric BE1-GPS100-E4N1H1N Protection System
  • Allen-Bradley 442G-MABH-R Safety Module
  • Beckhoff CX1030-0111 PLC Assembly Profile
  • FANUC IC693CPU364 PLC Module
  • Orange Denmark Type 200816 220 PLC Specs
  • OMRON C200H-SNT31 Sysmac PLC Module
  • Allen Bradley 20AB022A3AYNANC0 PowerFlex 70
  • OMRON C200HW-PCU01 Position Control Unit
  • ABB AO845A-eA Analog Output Module
  • OMRON CJ1M-CPU22 CPU Unit
  • Allen Bradley 100-E265ED11 Contactor
  • Honeywell 51304511-100 Interface Module
  • SOLEXY BXF3S0101N0018 Gateway Module
  • OMRON CJ2H-CPU65 CPU Unit
  • Automation Direct GS2-45P0 AC Drive
  • M68-2000 2-Axis Motion CNC Controller
  • OMRON CJ1M-CPU11 V3.0 PLC CPU Unit
  • OMRON CJ1W-NC413 4-Axis Positioning Controller
  • OMRON 3G2A3-PRO16 Programming Console HMI
  • Siemens 3VT8440-2AA04-2GA2 Molded Case Circuit Breaker
  • Siemens 3RT5045 Contactor Series
  • OMRON C200HS-CPU01-E SYSMAC PLC Controller
  • OMRON C500-NC103-E Positioning Control Unit
  • OMRON CJ1W-TC001 Temperature Control Unit