Oil monitoring: Check the oil level every 8 hours, and replenish if it is below the "L" mark; Add fuel promptly when the fuel level is below 1/4.
Temperature monitoring: There are no abnormal hot hands on the side of the body during operation, and there are no foreign objects blocking the heat dissipation port. If the engine overheats, it will automatically shut down. After cooling, clean the heat dissipation fins and restart.
Adjustment operation:
If the circuit breaker trips due to excessive load, immediately disconnect part of the load, press the circuit breaker reset button, and then reconnect.
If the engine speed fluctuates during operation, it may be due to insufficient fuel supply or clogged air filter. Check if the fuel shut-off valve is fully open and if the air filter is clean.
Long term operation (exceeding 2 hours) requires regular inspection of the equipment's operating status to avoid overheating and cable overheating.
4. Shutdown process (operating in different scenarios)
(1) Normal shutdown
Disconnect all loads (unplug or turn off the device switch).
Run the generator without load for 3-5 minutes to cool down the engine and generator (to avoid direct shutdown due to high temperatures causing carbon buildup).
Turn the start switch to the "STOP" position to shut down the engine; Close the fuel shut-off valve (set to "OFF").
Close all waterproof covers of sockets and cover with dust covers (if not used for a short period of time).
(2) Emergency shutdown (fire, leakage, abnormal noise, etc.)
Directly turn the start switch to the "STOP" position and force the machine to stop (without disconnecting the load).
Follow up processing: Investigate the cause of the malfunction (such as fuel leakage, engine noise), eliminate the fault before use, and prohibit restarting without troubleshooting.
(3) Long term shutdown (exceeding 1 month)
Disconnect the load according to the normal shutdown process and run it without load for 1 minute.
Close the fuel shut-off valve and allow the engine to continue running until the fuel runs out and automatically shuts down (to avoid fuel deterioration and blockage in the carburetor).
Disconnect the battery connection (first unplug the negative cable, then unplug the positive cable), fully charge the battery, and store it separately (to avoid damage due to low battery).
Clean the dust and oil stains on the surface of the generator, check the condition of the air filter and spark plug, and clean them if necessary.
Inject 1 teaspoon of new engine oil into the cylinder and pull the starting rope 3-5 times (without ignition) to evenly distribute the oil on the cylinder wall (rust prevention).
Cover with a dust cover and store in a dry, ventilated, and cool room (do not store in flammable areas).

Complete maintenance process (including cycle and details)
1. Preparation before maintenance
Safety measures: Turn off the generator, disconnect the battery connection, and allow the engine to cool to room temperature (to avoid high-temperature burns); Operate in a well ventilated area and prepare tools (wrench, oil pan, funnel, wire brush, etc.).
Tool list: Cross/Phillips screwdriver, spark plug socket wrench, 10mm/13mm wrench, oil pan, funnel, cleaning cloth, compressed air (optional), new engine oil, fuel stabilizer, spare spark plug.
2. Routine maintenance items (executed on a periodic basis)
Before/after each use
Cleaning: Use a dry cloth to wipe the dust and oil stains on the surface of the machine body, clean the debris on the heat sink and ventilation openings (to avoid blockage that affects heat dissipation); Check if the waterproof cover of the socket is intact.
Check:
Appearance: The components are not loose or damaged, and the oil pipes and oil pipe joints are not leaking.
Oil level: The engine oil level is between "L" and "H", the fuel gauge shows sufficient, and there is no leakage.
Battery: The connection is firm, without bulging or leakage (lead-acid batteries need to check the electrolyte level, and if it is insufficient, add distilled water).
Cable and plug: No damage or aging, and the plug has good contact.
GFCI test: After starting the generator, test the leakage protection function of the socket (press the "TEST" button to trip and the "RESET" button to reset).
Run every 8 hours (or after each use)
Oil level check: Add oil to the standard level (not exceeding the "H" mark).
Fuel filter inspection: Observe whether there is moisture or impurities in the sedimentation cup. If there are, unscrew the drain screw to drain it, and then tighten it again.
3. Long term storage and maintenance (over 3 months)
Preparation before storage:
Cleaning: Thoroughly wipe off dust and oil stains on the surface of the body, clean up debris from the heat sink and ventilation vents.
Fuel treatment:
Method 1 (Adding Stabilizer): Fill up with fresh fuel, add fuel stabilizer (according to the instructions), start the engine and run for 5 minutes, let the stabilizer circulate to the fuel system, and close the fuel shut-off valve and battery switch.
Method 2 (Drain Fuel): Close the fuel shut-off valve, unscrew the carburetor float drain screw, and drain the fuel; Unscrew the fuel tank drain screw, drain the fuel from the tank, and then tighten all screws.