Personnel management: Children and pets should stay away from the running generator (at least 3 meters away); Do not operate the generator when fatigued, under the influence of alcohol, or after taking medication (which affects judgment).
Emergency response:
If symptoms such as dizziness, nausea, and fatigue occur after inhaling carbon monoxide, immediately transfer to fresh air and seek medical attention in severe cases.
If burns occur (due to contact with high-temperature components such as mufflers), immediately rinse the burned area with cold water, and seek medical attention in severe cases.
If a fire occurs, use ABE or BE type fire extinguishers to extinguish it (it is prohibited to directly extinguish electrical or fuel fires with water).
Complete operation process (assembly → start → run → stop)
1. First use assembly and preparation
Open box inspection:
Remove the generator and its accessories (wheel kit, feet, tool kit, oil, battery, manual, quick guide).
Check that the appearance of the generator is undamaged, the components are not loose, the sockets and switches are functioning properly, and the battery is fully charged (voltage ≥ 12V).
Install wheels and feet:
Tilt the generator (ensuring that the fuel shut-off valve is closed to avoid fuel leakage), and use the attached M8 flange bolts to secure the support feet on both sides of the bottom of the fuselage.
Thread the wheel axle pin through the wheel and body bracket, insert the washer, insert the split pin and bend it to lock, ensuring that the wheel rotates flexibly and is securely installed (which can drive the generator to test stability).
Install battery:
Find the battery compartment on the body, first connect the red positive cable to the positive pole (+) of the battery, and put on an insulating sheath; Connect the black negative cable to the negative pole of the battery (-), and also cover it with a protective sheath (to avoid short circuits between the positive and negative poles).
Confirm that the cable connection is secure, fix the battery in the battery compartment, and avoid shaking during operation.
Add engine oil:
Place the generator on a level surface, unscrew the oil filler cap on the side of the body, and take out the dipstick.
Slowly add the recommended model of engine oil (SAE 10W-30) and check the dipstick while adding until the oil level is between the "L" (lowest) and "H" (highest) marks (not exceeding the "H" mark to avoid excessive oil accumulation and oil leakage).
Tighten the oil filler cap and dipstick, and wipe off any remaining oil with a dry cloth.
Add fuel:
Unscrew the fuel tank cap (counterclockwise) and clean the impurities around the fuel inlet.
Add unleaded gasoline of grade 87 or above, with the fuel level not exceeding the lower edge of the filling port, and tighten the fuel tank cap (clockwise).
Check for leaks at the connection between the fuel tank and oil pipe. If there is any overflow, wipe it clean immediately.
2. Start the process
Preprocessing:
Confirm that the generator is placed horizontally, the fuel shut-off valve is turned to the "ON" position, all loads have been disconnected, and the circuit breaker is in the reset state.
Cold engine start: Set the air door to the "ON" position (close the air door to increase fuel concentration); Hot engine start: Keep the air door in the "OFF" position (open the air door).
Startup mode selection:
Electric start: Press and hold the "START" button on the control panel for 1 second, and release it immediately after the engine starts (to avoid damaging the starter motor); If it fails to start once, try again after a 15 second interval (up to 3 times, if unsuccessful, switch to manual start).
Manual start: Turn the start switch to the "RUN" position, slowly pull the start rope until there is resistance (piston compression stroke), and then quickly and forcefully pull the handle; After starting the engine, slowly release the starting rope.
Stable operation:
After starting, let the generator run without load for 3-5 minutes, and gradually turn the air damper to the "OFF" position (adjust according to the engine operating status to avoid unstable idle).
Observing the control panel: The hour meter is counting normally, the fuel gauge shows sufficient, the circuit breaker is not tripped, and there is no abnormal noise (such as knocking or whistling).
Load connection:
According to the principle of "high power first, low power later", connect the devices one by one, ensuring that the plug is fully inserted to avoid loosening and heating.
If connecting to a 240V device, a dedicated L14-30R locking plug is required. After insertion, rotate it clockwise 1/4 turn to lock it; If 120V devices are used simultaneously, the load should be balanced through socket color identification (red/green identification for each device with the same power) to avoid abnormal generator vibration.
3. Monitoring and regulation during operation
Real time monitoring points:
Power monitoring: Total operating power ≤ 6000W, avoid long-term full load operation (recommended ≤ 80% load to extend engine life).