Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS220PPRAS1A Emergency Turbine Protection Terminal Board
    ❤ Add to collection
  • GE IS220PPRAS1A Emergency Turbine Protection Terminal Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS220PPRAS1A Emergency Turbine Protection Terminal Board

    • ¥24587.90
      ¥24352.25
      ¥24587.90
      ¥24587.90
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:5.080KG
    • Quantity:
    • (Inventory: 16)
Description

GE IS220PPRAS1A Emergency Turbine Protection Terminal Board


GE IS220PPRAS1A Emergency Turbine Protection Terminal Board

Part Number IS220PPRAS1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS220PPRAS1A is an Emergency Turbine Protection Terminal Board manufactured and designed by General Electric as part of the Mark VIe Series used in distributed control systems. A backup Overspeed protection system that is independent is offered by the Emergency Turbine Protection (PPRA) I/O packs and related TREA terminal board. Inputs for the main control and isolated trip contacts are also given a separate watchdog role by them. 

A protection system is made up of three triple modular redundant (TMR) PPRA I/O packs that are mounted to a TREA terminal board and have a WREA option board attached. The standard Mark VIe PPRO Emergency Turbine Protection I/O pack is the ancestor of PPRA. In applications where dual-speed sensors per shaft are fanned to three protective I/O packs, it needs new hardware and modified code to provide six-speed inputs. The majority of the PPRA's settings, parameters, and behavior are the same as those in the PPRO. The TREA terminal board with the WREA option board is the only one that supports PPRA. Other settings that PPRO supports cannot be used with PPRA. In order to communicate with the control modules through IONet, PPRA additionally has an Ethernet connection. The primary and backup trip prevention systems for the Mark VIe control are built to work together at the trip terminal board level. The Turbine Primary I/O pack (PTUR), when connected with PPRA/TREA, operates a primary trip board (usually TRPA), providing primary protection. 

A TREA terminal board installed with PPRA offers backup protection. PPRA supports six-speed signals (specified as three sets of speed pairs) for hardware-implemented Overspeed protection, acceleration, and deceleration. It keeps an eye on the primary control's performance. Through a thorough set of feedback signals, PPRA keeps track of the status and functionality of the TREA trip board. The backup trip relays on the TREA board will trip in the event of a failure, and the primary control will also trip. The primary control operation has no impact on PPRA and is completely independent of it. 

 COMPATIBILITY: For usage in IEC 61511-approved safety loops, PPRA is offered in a version that is IEC 61508 certified. The certified versions of the PPRA module are PPRAS1A with TREAS1A and WREAS1A. When using TREA, which PPRA mounts on directly, the WREA option board must be installed on the PPRA application-specific circuit board Option Header connector. Only three PPRA I/O packets will work properly with a PPRA installed on a TREA with WREA. It is not possible to operate a single or twin pack. In systems with a single controller, the R network of the controller, the S network of the controller, the JY1 connector of the controller, and the JZ1 connector of the controller should all be linked to the PPRA. The same controller powers all three networks. INSTALLATION: Mount the TREA terminal board firmly. Immediately connect the TREA with three PPRA I/O packets. 

Using the holes on the terminal board mounting bracket, insert the threaded posts on PPRA that are situated on either side of the Ethernet ports. To ensure a tight fit between the DC-62 pin connector on the PPRA and the terminal board, adjust the bracket's position. Secure the mounting bracket firmly. Only one adjustment should be necessary during the lifespan of the product. Lock PPRA in place by firmly tightening the nuts on the threaded posts. Depending on the setup of the machine, connect either one or two Ethernet wires. Ethernet connections are not sensitive to PPRA, which chooses the appropriate operation over either port. Connect the module's power connector to an electrical source to supply power. 

The I/O module has a built-in soft-start feature that regulates current levels when used. Configure the module using the ToolboxST* program as appropriate. OPERATION: A processing board is shared by each Mark VIe Ethernet I/O pack or module. It contains the following: A quick processor with RAM and flash memory is number one. Two plugs for entirely independent 10/100 Ethernet ports Hardware reset and watchdog timer circuit A sensor for internal temperature LEDs that indicate the status The capacity to read IDs on other boards and electronic identification An input power connector with a current limiter and a soft start Local power supplies, which also include monitoring and sequencing.

SPECIFICATIONS:

Part Number: IS220PPRAS1A
Manufacturer: General Electric
Series: Mark VIe
Product Type: Emergency Turbine Protection Terminal Board
Board Size: 8.26 cm High x 4.19 cm
Technology: Surface Mount
Operating Temperature: -30 to 65oC
Repair: 3-7 Days
Country of Origin: USA
Availability: In Stock
Manual: GEH-6721L


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice