Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS220PPRAS1A Emergency Turbine Protection Terminal Board
    ❤ Add to collection
  • GE IS220PPRAS1A Emergency Turbine Protection Terminal Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS220PPRAS1A Emergency Turbine Protection Terminal Board

    • ¥24587.90
      ¥24352.25
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:5.080KG
    • Quantity:
    • (Inventory: 16)
Description

GE IS220PPRAS1A Emergency Turbine Protection Terminal Board


GE IS220PPRAS1A Emergency Turbine Protection Terminal Board

Part Number IS220PPRAS1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS220PPRAS1A is an Emergency Turbine Protection Terminal Board manufactured and designed by General Electric as part of the Mark VIe Series used in distributed control systems. A backup Overspeed protection system that is independent is offered by the Emergency Turbine Protection (PPRA) I/O packs and related TREA terminal board. Inputs for the main control and isolated trip contacts are also given a separate watchdog role by them. 

A protection system is made up of three triple modular redundant (TMR) PPRA I/O packs that are mounted to a TREA terminal board and have a WREA option board attached. The standard Mark VIe PPRO Emergency Turbine Protection I/O pack is the ancestor of PPRA. In applications where dual-speed sensors per shaft are fanned to three protective I/O packs, it needs new hardware and modified code to provide six-speed inputs. The majority of the PPRA's settings, parameters, and behavior are the same as those in the PPRO. The TREA terminal board with the WREA option board is the only one that supports PPRA. Other settings that PPRO supports cannot be used with PPRA. In order to communicate with the control modules through IONet, PPRA additionally has an Ethernet connection. The primary and backup trip prevention systems for the Mark VIe control are built to work together at the trip terminal board level. The Turbine Primary I/O pack (PTUR), when connected with PPRA/TREA, operates a primary trip board (usually TRPA), providing primary protection. 

A TREA terminal board installed with PPRA offers backup protection. PPRA supports six-speed signals (specified as three sets of speed pairs) for hardware-implemented Overspeed protection, acceleration, and deceleration. It keeps an eye on the primary control's performance. Through a thorough set of feedback signals, PPRA keeps track of the status and functionality of the TREA trip board. The backup trip relays on the TREA board will trip in the event of a failure, and the primary control will also trip. The primary control operation has no impact on PPRA and is completely independent of it. 

 COMPATIBILITY: For usage in IEC 61511-approved safety loops, PPRA is offered in a version that is IEC 61508 certified. The certified versions of the PPRA module are PPRAS1A with TREAS1A and WREAS1A. When using TREA, which PPRA mounts on directly, the WREA option board must be installed on the PPRA application-specific circuit board Option Header connector. Only three PPRA I/O packets will work properly with a PPRA installed on a TREA with WREA. It is not possible to operate a single or twin pack. In systems with a single controller, the R network of the controller, the S network of the controller, the JY1 connector of the controller, and the JZ1 connector of the controller should all be linked to the PPRA. The same controller powers all three networks. INSTALLATION: Mount the TREA terminal board firmly. Immediately connect the TREA with three PPRA I/O packets. 

Using the holes on the terminal board mounting bracket, insert the threaded posts on PPRA that are situated on either side of the Ethernet ports. To ensure a tight fit between the DC-62 pin connector on the PPRA and the terminal board, adjust the bracket's position. Secure the mounting bracket firmly. Only one adjustment should be necessary during the lifespan of the product. Lock PPRA in place by firmly tightening the nuts on the threaded posts. Depending on the setup of the machine, connect either one or two Ethernet wires. Ethernet connections are not sensitive to PPRA, which chooses the appropriate operation over either port. Connect the module's power connector to an electrical source to supply power. 

The I/O module has a built-in soft-start feature that regulates current levels when used. Configure the module using the ToolboxST* program as appropriate. OPERATION: A processing board is shared by each Mark VIe Ethernet I/O pack or module. It contains the following: A quick processor with RAM and flash memory is number one. Two plugs for entirely independent 10/100 Ethernet ports Hardware reset and watchdog timer circuit A sensor for internal temperature LEDs that indicate the status The capacity to read IDs on other boards and electronic identification An input power connector with a current limiter and a soft start Local power supplies, which also include monitoring and sequencing.

SPECIFICATIONS:

Part Number: IS220PPRAS1A
Manufacturer: General Electric
Series: Mark VIe
Product Type: Emergency Turbine Protection Terminal Board
Board Size: 8.26 cm High x 4.19 cm
Technology: Surface Mount
Operating Temperature: -30 to 65oC
Repair: 3-7 Days
Country of Origin: USA
Availability: In Stock
Manual: GEH-6721L


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide