The LAUER SYSTEME LCA142 is a compact, DIN‑rail‑mountable industrial controller designed for decentralized automation tasks. It combines a powerful logic engine with a versatile set of communication interfaces, enabling seamless integration into existing fieldbus networks. The unit is particularly suitable for machine‑side control, conveyor systems, and auxiliary process loops where space is limited but reliability is paramount.
The LCA142 is equipped with a 32‑bit ARM Cortex‑M4 processor running at 120 MHz, with 512 KB of flash memory for firmware and user programs, and 128 KB of SRAM for runtime data. The real‑time clock (RTC) is battery‑backed (coin cell) with a typical lifetime of 5 years. The controller supports up to 16 user‑defined tasks with cycle times as low as 1 ms, making it capable of handling high‑speed interlocks and time‑critical signal processing.
Digital Inputs: 8 channels, 24 V DC (sink/source, IEC 61131‑2 type 1), optically isolated
Digital Outputs: 6 channels, 24 V DC, 0.5 A per channel, short‑circuit protected
Analog Inputs: 2 channels, 0‑10 V or 4‑20 mA (software‑selectable), 12‑bit resolution
Communication Ports: 1x RS‑232 (programming/debug), 1x RS‑485 (Modbus RTU master/slave), 1x CANopen (DS301)
Ethernet: 10/100 Base‑T with Modbus TCP, OPC UA (optional firmware)
Expansion Bus: LAUER S‑Bus for up to 4 additional I/O modules (digital, analog, temperature)
The LCA142 is programmed using the LAUER Ladder Studio software, which supports all five IEC 61131‑3 languages (LD, FBD, ST, IL, SFC). The programming environment includes a built‑in simulator, online monitoring, and a watchdog configuration tool. The controller retains the user program in non‑volatile memory; a boot‑up self‑test checks the program integrity via CRC. For remote diagnostics, the controller supports the LAUER Service Protocol (LSP) over Ethernet, allowing secure access to variables, error logs, and performance metrics.
Housing: Polyamide (UL 94 V‑0), width 45 mm, height 100 mm, depth 75 mm
Mounting: DIN rail (EN 50022) – snap‑on
Protection Rating: IP20 (requires enclosure for IP54 applications)
Operating Temperature: –10 °C to +55 °C
Storage Temperature: –20 °C to +70 °C
Relative Humidity: 5 – 95 % (non‑condensing)
Power Supply: 24 V DC ±15 %, max 150 mA (plus load on outputs)
Snap the controller onto the DIN rail until the latch clicks. Use the removable spring‑clamp terminal blocks for all I/O connections – strip wires to 8 mm and insert firmly. For the analog inputs, use shielded twisted‑pair cables and connect the shield to the ground terminal (GND) of the controller. The RS‑485 port requires a terminating resistor (120 Ω) at both ends of the bus; the controller has an onboard switch to enable/disable the termination. After wiring, apply 24 V DC power; the green LED will illuminate. The unit is ready for program download via the Ethernet or RS‑232 port.
Upon power‑up, the controller runs a self‑diagnostic routine; a successful start is indicated by a steady green RUN LED. The integrated web server provides a simple status page showing I/O states, firmware version, and communication counters. For advanced diagnostics, use the LAUER Diagnostic Tool (LDT) to view the error history, force outputs, or trace variable values in real time. Common faults: “Watchdog Timer Expired” – check for infinite loops in the user code; “Bus Off” – verify CAN termination and baud rate; “I/O Configuration Mismatch” – ensure the expansion modules are correctly addressed.
The LCA142 is maintenance‑free except for the replacement of the RTC battery (CR2032) every 5 years. Firmware updates are released periodically; they can be applied through the Ethernet port using the LAUER Update Manager. Always back up the user program before performing an update. In the event of a hardware fault, the unit is designed to be replaced quickly – the terminal blocks are removable, so wiring does not need to be re‑terminated. Order the same part number LCA142 to ensure full compatibility with existing expansion modules and software licenses.