GE AT868 AquaTrans ™ Ultrasonic water flowmeter

来源: | 作者:FAN | 发布时间 :2025-08-12 | 423 次浏览: | 🔊 Click to read aloud ❚❚ | Share:

GE AT868 AquaTrans ™  Ultrasonic water flowmeter

Product Overview

Core functions

AT868 is an ultrasonic water flow meter (supporting 1 or 2 channels) that measures water flow velocity, volumetric flow rate, and mass flow rate based on the principle of time difference. It is suitable for flow monitoring of single-phase fluids such as clean water and sewage. It emits and receives signals through ultrasonic sensors, calculates fluid flow velocity, and converts it into flow data, supporting real-time display, data recording, and multiple output methods (analog, pulse/frequency).

Main features 

Multi channel configuration: Standard 1 channel, optional 2 channels, improve accuracy by measuring average, difference, or sum through dual channels.

Flexible sensor types: Supports wet and clamp on sensors to meet different pipeline installation requirements.

Rich output and communication: equipped with 0/4-20mA analog output, pulse/frequency output (for total count), supports RS232/RS485 serial communication, compatible with PanaView ™ Software remote operation.

High adaptability: Suitable for pipe diameters ranging from 0.04 inches to 200 inches (1mm to 5m), with flow rates ranging from -40 to 40 feet per second (-12.2 to 12.2m/s), meeting the needs of industrial pipeline flow monitoring.

Installation and wiring

1. Installation points

Sensor location: It needs to be installed in a straight pipe section, with at least 10 times the upstream pipe diameter and at least 5 times the downstream pipe diameter without turbulence interference (such as valves, elbows); Prioritize installation on the side of the pipeline (to avoid gas accumulation at the top or slag accumulation at the bottom).

Electronic enclosure: Adopting NEMA 4X/IP66 protection level, suitable for indoor and outdoor installation, should be close to the sensor to shorten the cable length (supporting up to 1000 feet/300 meters).

Pipeline requirements: It is necessary to measure the outer diameter, wall thickness, material and other parameters of the pipeline and program them to ensure the accuracy of flow calculation.

2. Wiring specifications

Power supply: Supports 85-265VAC or 12-28VDC, requires an external power-off device (such as a switch) that complies with the EU Low Voltage Directive, installed within a range of 6 feet.

Sensor wiring: Plug in or clip on sensors are connected through coaxial cables, and the cable length needs to be matched (with an error of ≤ 4 inches for frequencies ≤ 2MHz and ≤ 0.5 inches for frequencies>2MHz).

Output wiring:

Analog output (0/4-20mA): Load resistance ≤ 600 Ω, used for transmitting flow signals.

Pulse/frequency output: used for total count or frequency proportional to flow, maximum load 3A@100VDC .

Communication wiring: RS232 is used to connect to PCs or printers, RS485 supports multi device networking, and must follow shielding grounding specifications to resist interference.

Programming and Settings

1. Basic parameter configuration

Channel activation: Activate the channel through the CHx ACTIV menu and select the sensor type (standard or special).

System parameters: Set the flow unit (such as gallon/minute, cubic meter/hour), total unit, and decimal places in CHx SYSTM, and optional mass flow rate (fluid density needs to be entered).

Pipeline and sensor parameters: Enter pipeline material, outer diameter, wall thickness, sensor frequency, path length (P), and axial length (L) in CHx PIPE. For clamp on sensors, lining parameters (material, thickness) also need to be set.

2. Advanced feature settings

Response time: Set the average measurement response time through the AVRG menu. It is recommended to select the "STATS" mode (fast response in steady state, fast tracking when flow changes).

Zero flow cutoff: Set a zero flow threshold (0-1 feet/second) in CHx I/O to avoid reading deviations caused by small fluctuations.

Tracking window: When the fluid sound velocity is unknown or fluctuates greatly, enable Tracing WINDOW to automatically track the sound velocity to ensure measurement accuracy.

Display function

1. Display screen and indicator lights

LCD display screen: A 2-line x 16 character LCD display screen that supports backlight adjustment and can display real-time measurement data, set parameters, and error codes.

Display content: It can be configured to display up to 4 parameters, including:

Flow rate (feet/second, meters/second)

Volume flow rate (such as gallons per minute, cubic meters per hour)

Accumulated total amount (such as total cubic feet, total cubic meters)

Diagnostic parameters (such as signal strength, sound speed, time difference, etc.)

Wheel display function: If multiple parameters are configured, the display screen will cycle at set intervals, with each parameter staying for a few seconds.

2. Display settings

Enter the settings menu:

Press [ESC]+[ENTER]+[ESC] to enter the user program.

Navigate to PROG → GLOBL → I/O → LCD, set the number of display parameters and specific parameters.

Parameter selection: Select the content to be displayed from the measured values (flow rate, flow rate) and diagnostic values (signal strength, sound velocity), supporting custom units (imperial/metric).

  • ABB UFC921A101 Main Control Board
  • ABB UFC921A Main Control Unit
  • ABB UFC911B108 Drive Main Control Unit
  • ABB UFC911B106 Drive Main Control Unit
  • ABB UFC911B101 Drive Main Control Unit
  • ABB UFC765AE102 Drive Control Interface Board
  • ABB UFC762AE101 I/O and Communication Extension Board
  • ABB UFC760BE41 I/O and Communication Extension Board
  • ABB UFC760BE145 I/O and Communication Extension Module
  • ABB UFC721BE101 Fieldbus Communication Adapter Module
  • ABB UFC721AE101 3BHB002916R0101 Network Interface
  • ABB UFC718AE101 HIEE300936R0101 Communication Module
  • ABB UDC920BE01 3BHE034863R0001 Communication Module
  • GE IS420UCSCH1A-F-VO.1-A Controller Module
  • GE UCSC H1 IS420UCSCH1A Controller Station Card
  • ABB UCD240A101 3BHE022287R0101 Process Controller
  • ABB UCD224A103 Process I/O Module
  • ABB UCD224A102 Analog Input Module
  • WOODWARD 9907-838 Load Sharing Module
  • B&R X20CP1485-1 Industrial PC CPU Module
  • ELAU MC-4/11/22/400 4-Axis Servo Drive
  • ELAU C600/10/1/1/1/00 Configurable Safety Relay
  • BENTLY 60R/SIM01 Proximitor Power Supply
  • BENTLY 60R/PPM01 Protection Processing Module
  • BENTLY 60R/PNL01 Operator Control Panel
  • BENTLY 60R/PIM01 Panel Interface Module
  • BENTLY 60R/INP07 Isolated DC Input Module
  • BENTLY 60R/INP01 4-Channel Analog Input Module
  • BENTLY 60R/CMM01 Communication Multiplexer Module
  • BENTLY 60R/CHA02 System Chassis Rack Enclosure
  • BENTLY 60R/CGW01 Condition Monitoring Gateway
  • Pacific Scientific P70360-SDN Servo Motor
  • HONEYWELL 05701-A-0284 Signal Conditioner
  • YOKOGAWA NFCP501-W05 Pressure Transmitter
  • ABB CI541V1 3BSE0146666R1 Control Interface
  • ABB DSTC176 57310001-KT Terminal Base Unit
  • ABB DSDP170K02 3BSE019925R1 Analog Input Module
  • ABB DSBC173 57310001-KH Terminal Base Unit
  • ABB DSAI130K01 5730-030-UC Thermocouple Input
  • ABB DSRF182 57310255-AL Relay Output Module
  • ABB SC520 3BSE003816R1 Compact PLC
  • ABB DSDP140A 57160001-ACT Analog Input Module
  • ABB DSAI130 57120001-P Analog Input Module
  • ABB SCYC55830 3AFE58063282 MCCB
  • Fireye 95DSS3-1CEX UV Flame Scanner
  • ABB DSDP170 57160001-ADF Analog Input Module
  • ABB CI532 3BSC140120R1 Communication Interface
  • ABB DSAO120A 3BSE018293R1 Analog Output Module
  • ABB CI869K01 3BSE049110R1 Ethernet Interface
  • ABB CI522A 3BSE018460R1 PROFIBUS DP Master
  • GUTOR OP6257 Rectifier Control Unit
  • Meggitt C327845-11 Gas Shutoff Valve
  • ABB SACO64D4 4-Pole Digital Annunciator Unit
  • ABB CI522AK04 3BSE018451R1 PROFIBUS DP Module
  • ABB DSAI130DK01 3BSE020828R1 Temperature Input Module
  • ABB CI546 3BSE012610R1 PROFIBUS DP Master Module
  • ABB SC510 3BSE003832R1 Compact PLC Controller
  • ABB CI540 3BSE001077R1 PROFIBUS DP Slave Module
  • ABB CI532V03 3BSE003828R1 AF 100 PROFIBUS DP Master
  • ABB DSBC172 57310256-EL Digital Input Terminal Base
  • Rexroth VT2000-5X Frequency Converter AC Drive
  • GE MAVS01L1AB0751D-140393N Soft Starter
  • ABB REF615 HBFDACADNAA1BCN1XE Relay
  • ABB SACO16D1 1-Pole Digital Annunciator Unit
  • ABB UNITROL 1000 3BHE014557R0003 Static Excitation System
  • Woodward 8273-1011 Electro-Hydraulic Actuator
  • Eaton MC2-442-57CQB-1-2A Molded Case Circuit Breaker
  • Siemens 3AY1715-6L VS30029P VS30041 Auxiliary Contact Block
  • ABB PCD235B101 3BHE032025R0101 Digital I/O Control Module
  • Socapel PAM-R1R-H8F-AP-P V10800 Programmable Axis Manager
  • Rexroth VT-HNC100-1-23N-08-P-0 Digital Hydraulic Amplifier
  • Woodward 5448-890 SPM-D10 Digital Synchronizer
  • TDK-Lambda HWS1500-24 Industrial Power Supply
  • Land M2300/1100C-V Infrared Pyrometer
  • Lantronix 080-332-000-R Industrial Device Server
  • LED E14 3W Miniature LED Lamp
  • LEM LC100S/SP7 Hall Effect Current Sensor
  • Lenel LNL-1320 Dual Reader Interface Module
  • Lenze L5311 Industrial Control Module
  • Lenze EPZ-10203 Safety Controller
  • Lenze EPL10200 Industrial Drive Module
  • Lenze EPL-10200-XX Drive Controller
  • Lam Research 810-801237-021 Industrial Part
  • Lam Research 810-073479-215 Precision Part
  • Lam Research 853-001983-110 Assembly Data
  • Lam Research 810-017034-005 Semiconductor Part
  • Lambda LZS-A1500-3 AC-DC Power Module
  • Lambda LZS-1500-3 Industrial Power Supply
  • LAM 810-072907-005 Chamber Interface Control Module
  • LAM 810-068158-014 Semiconductor Process Control Module
  • LAM 810-800081-018 Vacuum System Interface Module
  • LAM 810-068158-013 Semiconductor Control Module
  • Leybold CM330 Vacuum Gauge Controller
  • Leybold 850-400-G1 Vacuum Pump Module
  • LIFTMASTER 71-1550B18LGH Electric Actuator
  • LKB Bromma 2211 Pressure Sensor
  • LLASERGAS AO2000 LS25 12944-E Gas Analyzer Module
  • Load Controls PH-3A Three-Phase Power Sensor
  • Ludlum 2401-P Pancake GM Survey Meter
  • LUST VF1410LHFS41 AC Servo Drive
  • LUTZE UBE-FL/34M Terminal Block Contact
  • Marposs E78 Dynamic Balancing Controller
  • LENZE E84AVSCE1534VX0 Servo Drive Controller
  • LENZE EVF8212-E Frequency Inverter Drive
  • LENZE EA-4/10 Drive Expansion Module
  • LENZE BG10 Brake Module
  • LEUZE DDLS 200/200.1-50-M12 Data Link Data
  • LEUZE DDLS 200/200.2-50-M12 Optical Data
  • LEYBOLD TURBOVAC 361 Turbomolecular Pump
  • LEYBOLD TR211 Vacuum Controller Data
  • LEYBOLD SV40BI Rotary Vane Pump Specifications
  • LEYBOLD PR25 Vacuum Pressure Sensor Data
  • MARPOSS E9066 Precision Measurement Control Unit
  • MATROX Y7116-04 REV A Industrial Vision Processing Board
  • MATROX Y7116-01 REV A Industrial Video Processing Board
  • MCS SA1000 Industrial Signal Amplifier Module
  • MECS CS-1000 Control System Hardware Data
  • MECS UTX1010 Industrial Control Module
  • MECS UTX-1000A Industrial Module
  • MECS UTV-F2500HA High-Power Thyristor Data
  • MECS EXT-2 Advanced Expansion Interface
  • MECS EXT-1 Interface Extension Module
  • MECS CPU-1000 Industrial PLC Controller
  • MEN A201SR04 Embedded Computer
  • MERAK 681H10078 681K10078 681K10079 Control Modules
  • Mercury Step C-663 Stepper Motor Controller
  • MERLIN GERIN MX+0F 26948 Shunt Trip Release
  • MERLIN GERIN 32570 Miniature Circuit Breaker