Switch position valve type comparison: plug and play configuration for over 50 valve types
The core value of the amplifier lies in the direct selection of valve type by the rotary switch, without the need for external parameterization tools. The switch position is a two digit number (ten positions x one position, 0-0 to 9-8), divided into two sets of mapping tables according to the number of valve electromagnets:
VT-MSPA1 (single electromagnet) main mapping (component series requirements in parentheses):
0-0 No valve; 0-1 is 4WRA6... -2X; 0-2 is 4WRA10... -2X; 0-3 is 4WRZ... -7X; 0-4 is 3DREP6... -2X; 0-5 is 4WRPH6... -2X (SO855); 0-6 is DBEP6... -1X; 0-7/0-8 are DBET-6X/7X... G24 (G24-8 variant); 0-9/1-0 is DBTX-1X... G24-25/G24-8; 1-1 to 1-7 are (Z) DBE6-2X and DBEM10/20/30... -7X series (G24/G24-8); 1-8 to 1-9 are (Z) DRE6... -1X and ZDRE10... -2X... G24; 2-0 to 2-6 are ZDRE10, DRE... 10/20/30... -6X series (G24-8 variant); 2-7/2-8 is 3DRE... -7X... G24 (G24-8); 2-9/3-0 is 3FREX6/10... -1X... G24-25; 3-1 is 3DREP6... -2X... (SO674); 3-2 is Z3DRE10... -1X... G24 (starting from component series 21); 3-3 to 3-6 are DBE6X-1X... G24-25/G24-8, DRE6X-1X-G24-8, DBET-1X... HG24-8 (starting from component series 21);
Pump control dedicated position: 3-7 pump control 1 (0.7 A) EP2 (A7VO); 3-8 pump control 2 (0.6 A) ED72/ER72 (A10VSO/31); 3-9 pump control 3 (0.6 A) EP2/EK2 (A10VSO/52,53), L4/E2 (A15VSO...), EP2,6 (A6VM); 4-4 pump control 4 (1.9 A) U7 (A15VSO...), EC4 (A10VSO...); 4-5 Pump Control 5 (2.7 A) U8 (A15VSO...), EB4 (A10VSO...) - Pump Control 4/5 requires component series starting from 23;
4-0/4-1 refers to DBE10Z-1X... G24-8, DRE10Z-1X... G24-8 (starting from component series 21); 4-2/4-3 are (Z) 3DRE6... -2X/... G24 (G24-8, component series 22 onwards);
Universal position: 9-6 universal (0.8 A), 9-7 universal (1.6 A), 9-8 universal (2.5 A) - used for valve types not listed in the table.
VT-MSPA2 (Dual Electromagnetic) Mapping: Only 0-1 to 0-6 (4WRA6/10... -2X, 4WRZ... -7X, 3DREP6... -2X, 3DREP6... -2X (SO674), DBEP6... -1X), 3-7 Pump Control 1 (0.74 A) EP (A4CSG), and 9-6/9-7/9-8 universal positions are valid, while the rest of the switch positions are "-" (invalid) - the selection range for dual electromagnetic applications is significantly narrowed, and the table must be checked before selection.
Installation, Environment, and EMC Compliance
Installation position: Vertical installation; To ensure the breathing and heat dissipation of the device, the top and bottom ventilation ducts should be at least 2 cm away from the cover plate, wall, etc. When the ambient temperature exceeds 50 ℃, the distance between adjacent devices should be 1 cm. The ambient temperature should be 0...+60 ℃; Storage (UV protection)+5...+40 ℃; Transportation -40...+70 ℃; Relative humidity 10... 95% (no condensation); Maximum usage altitude of 2000 meters; maximum temperature change of 5 ℃/min; Start time<1 s; UV resistance is conditional (prolonged exposure may cause discoloration); Free drop of 1 meter from original packaging; glass fiber reinforced polyamide shell; Prohibit contact with conductive dust and avoid contact with hydraulic oil.
Mechanical strength: sinusoidal test at 10... 500 Hz/maximum 2 g/10 cycles/3-axis (EN 60068-2-6); Noise test 20... 500 Hz/2.2 gRMS/6.6 g peak/0.5 h/3 axes (EN 60068-2-64); Transport impact 15 g/11 ms/3-axis (EN 60068-2-27); IP20 (EN 60529) - Only for installation inside control cabinets.
EMC Matrix (CE compliant with EMC Directive 2014/30/EU, RoHS 2011/65/EU): EN 61000-6-2 Immunity - ESD 4 kV CD/8 kV AD (BWK B), HF radiation 10 V/m(80…6000 MHz,BWK A)、Burst 2 kV(5/100 kHz,BWK B)、Surge 0.5 kV(2 Ω/12 Ω) to operating voltage and 1 kV (42 Ω) to signal (BWK B), HF conduction 10 Veff (150 kHz... 80 MHz, BWK A), magnetic field 50/60 Hz 100 A/m (BWK A); EN 61000-6-3/6-4 emission - Interference voltage 0.15... 30 MHz (Class A), RF interference field strength 30... 6000 MHz (Class B, EN 55016-2-1/-2-3)。

Terminal allocation and operation panel
12 Terminal Allocation Table: XH1- Terminal 1+UB, Terminal 2 0 V, Terminal 3 Electromagnetic B+, Terminal 4 Electromagnetic B −; XH2-5-terminal digital input, 6-terminal Ready, 7-terminal electromagnet A+, 8-terminal electromagnet A − (VT-MSPA2 only); X2A -9-terminal instruction value+, 10 terminal instruction value -, 11 terminal actual value+, 12 terminal actual value -.
Five elements of the front panel: ① Status LED group (displaying the current operating status, menu hierarchy, and error conditions); ② SET key (edit selected parameters, select work run, enter "expert mode"); ③ +/- keys (select parameters and adjust parameter values); ④ Rotary switch (valve type selection, 0-9 scale x two layers); ⑤ Measurement sockets (IB, IA, v, ⊥) - command value/set "v" to 0... ± 10 V, actual current value IA/IB to 0... ± 2.5 V (V ≙ A), reference potential "⊥", can be connected to an external multimeter for real-time observation of each node in the signal chain.
LED status diagnosis matrix (the first entry point for troubleshooting)
Yellow "Digital input" LED: normally running, constantly on/off=digital input status; Flashing in settings=standard settings activated; Setting to disable=Expert setting to activate; Settings: Bright/Flash/Tremble=Expert settings: Digital input settings.