EATON VISA series vacuum arc extinguishing chamber

来源: | 作者:FAN | 发布时间 :2026-03-10 | 17 次浏览: | Share:

3.3 Dual manufacturing base

Eaton has established dual manufacturing bases in North America and China, ensuring that customers can obtain stable supply from the other base regardless of production, delivery, or quality fluctuations in either region. This strategy greatly enhances the reliability and resilience of the supply chain.

3.4 Competitive pricing

Through standardized design, the VISA series avoids the high cost of customizing designs for each application in the past. Users can enjoy the price advantage brought by large-scale production while still receiving Eaton's consistent high-quality guarantee.

Overview of main application areas and corresponding models

The VISA series vacuum arc extinguishing chamber is widely used in various types of switchgear in medium and low voltage distribution systems, mainly including the following categories:

4.1 Circuit Breaker (VCB)

Used for the most stringent circuit protection scenarios, quickly disconnect overload and short-circuit currents. VISA Series-8 covers voltage levels from 12kV to 17.5kV, with a breaking capacity ranging from 25kA to 50kA; Series-9 covers voltage levels from 24kV to 40.5kV, with a breaking capacity ranging from 16kA to 40kA. Typical models include WL-41153 (17.5kV/31.5kA/1250A), WL-41456 (40.5kV/31.5kA/2500A), etc.

4.2 Recloser

Used for automatic opening and closing of distribution lines to cope with transient faults. Typical models such as WL-39352 (15.5kV/800A/16kA) and WL-42223 (27kV/1200A/16kA) have excellent automatic reclosing electrical life (E2 level).

4.3 Load switch (LBS)

Used for connecting and disconnecting normal load currents, with limited short-circuit closing capability. Typical models such as WL-41092 (24kV/630A/20kA) and WL-41093 (36kV/630A/16kA) meet the IEC 60265-1 and 62271-103 standards.

4.4 Contactor

Used for frequent operation of loads such as electric motors and capacitor banks. WL-41909 (12kV/400A/4kA) is designed specifically for high operating frequency applications of this type.

4.5 Railway Circuit Breaker

Used for traction power supply system, meeting single-phase 25kV/27.5kV railway standards. WL-41949WE (27.5kV/2500A/31.5kA) has a 250kV BIL insulation level and anti vibration design.


In depth analysis of core technical specifications

Select several typical models below and analyze their technical parameters and engineering significance in detail.

5.1 WL-41153:17.5kV/31.5kA/1250A arc extinguishing chamber for circuit breakers

This model is suitable for 12/15.5/17.5kV systems, with a rated current of 1250A and a rated short-circuit breaking current of 31.5kA.

Insulation level: The power frequency withstand voltage is 48kV, and the lightning impulse withstand voltage is 75/85/95kV (depending on the neutral grounding method), meeting the E2 level electrical life requirements.

Contact resistance:<15 μ Ω (@ 3300N contact force), low contact resistance means low power consumption and low temperature rise.

Mechanical characteristics: rated opening distance of 8.5 ± 0.5mm, average opening speed of 1.0-1.4m/s, closing speed of 0.9-1.1m/s, contact bounce time ≤ 2ms. These parameters ensure reliable opening and a long mechanical life (50000 operations).

Life indicator: The allowable wear of the contact is 3mm, and the storage life is 20 years (in original packaging, dry and clean environment).

5.2 WL-41456: Arc extinguishing chamber for 40.5kV/31.5kA/2500A circuit breaker

Suitable for 40.5kV system, high current 2500A, breaking capacity 31.5kA.

Insulation level: With a power frequency withstand voltage of up to 118kV and lightning impulse of 215kV, it meets the internal and external insulation requirements of higher voltage levels.

Mechanical requirements: opening distance 19 ± 1mm, average opening speed 1.6-2.0m/s, closing speed 1.4-1.6m/s, contact bounce ≤ 2ms. The larger opening distance and higher speed are for reliable arc extinguishing at higher voltages.

Additional quality requirements: It is stipulated that the mass of the moving part of the mechanism must be greater than twice the mass of the moving end (mu>2ma), in order to ensure sufficient closing kinetic energy and overcome the contact welding force.

5.3 WL-41092R: Arc extinguishing chamber for 24kV load switch

Compliant with IEC 62271-103 E3 level load switch requirements, rated current 630A, short-time withstand current 20kA/3s.

Special breaking capability: In addition to load current, it also has comprehensive capabilities such as closed-loop breaking, cable charging breaking, single capacitor bank breaking (400A), and ground fault breaking, reflecting the comprehensive performance of load switches.

Mechanical lifespan: 30000 operations, meeting frequent operation requirements.

5.4 WL-41949WE: 27.5kV Railway Special Circuit Breaker Arc Extinguishing Chamber

Single pole design, specifically designed for 25kV electrified railways.

Rated voltage: maximum permanent voltage 27.5kV, instantaneous maximum 29kV.

Insulation level: Power frequency withstand 95kV, lightning impulse 250kV, ensuring insulation reliability in harsh outdoor environments.

High current capability: rated current of 2500A, breaking 31.5kA, meeting the power supply needs of heavy-duty railways.

  • UNIOP eTOP20C-0050 Color HMI Touch Panel Data
  • UNIOP MD00R-02-0045 Text-Based Display Module
  • UNIOP eTOP05-0045 Operator Interface
  • UNIOP ETOP11-0050 HMI Color Operator Interface Data
  • UNIOP eTOP306 Industrial Touch Panel
  • UNIOP CP04F-04-0045 HMI Panel
  • UNIOP ETOP308U301 HMI Touch Panel
  • UNIOP MD00R-02-0045 Operator Panel
  • UNIOP ePALM10-0061 Handheld Teach Pendant
  • UNIOP CP05R-04-0045 HMI Operator Panel
  • UNIOP MD02R-04-0045 Text-Based Operator Module
  • UNIOP CP02R-04-0021 Compact Operator Panel
  • UNIOP CP04F-04-1945 Industrial HMI Control Panel
  • UNIOP ECT-16-0045 Communication Module Data Sheet
  • UNIOP EPALM10-0061 Handheld HMI Technical Specifications
  • UNIOP ERT-16-0042 Remote Terminal Unit
  • UNIOP ePAD04-0046 HMI Controller
  • UNIOP BKDR-16 Operator Interface Display
  • UNIOP MKDR-04-004 Control Unit Panel
  • UNIOP ETOP515U3P1 HMI Touch Panel
  • AMAT 0190-15779 Advanced Controller Module
  • Applied Materials AMAT 0010-23715 Mechanical Assembly
  • AMAT 0190-14502 Communication Interface Module
  • AMAT 0195-14157.RMA Power Distribution Module
  • Applied Materials AMAT 0021-84842 Precision Component
  • AMAT 0190-37519 DC Power Supply
  • AMAT 0100-71267 RF Generator Module
  • ALSTOM V4561484-0100 Analog Input Module
  • ALSTOM PIB903 Process Interface Board
  • ALSTOM 029.202.781 Protection Relay
  • ALSTOM 029.148.924 Enhanced Motor Relay
  • ALSTOM 029.148.906 Motor Protection Relay
  • ALSTOM 029.147.908 Transformer Protection Relay
  • ALSTOM 029.144.456 Advanced Feeder Relay
  • ALSTOM 029.144.440 Feeder Protection Relay
  • ALSTOM P40 AGILE MiCOM P141 Feeder Protection Relay
  • ALSTOM I/OBE2 12004-104-00 V1.0.0 I/O Interface Module
  • ALSTOM V4561983-0100 Industrial Control Module
  • ALSTOM VOOB8-B 12004-106-04 V1.0.0 Output Interface Board
  • ALSTOM VPS 12004-102-03 V1.0.0 Voltage Processing Board
  • ALSTOM POS1846 TRVC062333000 CP00000310 Position Control Module
  • ALSTOM DSI1817 TRVC062335000 CP00003934 Digital Input Module
  • ALSTOM CMP1838 TRVCO62345000 CP00005202 Processor Module
  • ALSTOM STO1726KO1 Integrated Control Module
  • ALSTOM I/OBUS2 12004-103-01 VER:V1.2.0 Communication Interface
  • ALSTOM 730475-D ELEMENTS-F2 Cabinet Heater
  • ALSTOM N897163510Q / N897163050Q MODEM and N897163100U Interface Unit
  • ALSTOM N897066 AOVD Analog Output Module
  • ALSTOM CMU 42015-115-00 Communication Unit
  • ALSTOM NRD108028 Digital Protection Relay
  • ALSTOM 42011-106-00 ITC_VIOM_VIOC VER.A01 Interface Card
  • ALSTOM N897093511D DIAGNOSTICA N897093400H Interface Unit
  • ALSTOM N895609510K N895609010R E32OUT Digital Output Module
  • ALSTOM MLU VER.A01 Main Logic Unit
  • ALSTOM NRD109475 8RDA44670G01 SA44670.E Control Module
  • ALSTOM VIIB16-C 12011-105-00 Interface Board Module
  • ALSTOM VCS232 590.043158 Control System Module
  • ALSTOM V0701596-001102 Industrial Control Module
  • ALSTOM N895313512X N95313012D SUP-AL Control Module
  • ALSTOM 12004-102-01 VPS Board Ver.C Power Control Board
  • ALSTOM NRD108034 8RDB44674G01 SA44674.C Control Card
  • ALSTOM N897092520B N897092057Y TRENO N897092500E
  • ALSTOM NRD108033 8RDC44667G01 SA44667.C Control Circuit Board
  • ALSTOM TRVC062105000 TRVC070938000 Series Specification
  • ALSTOM SDK-C0147 12004-101-00 SBS04M17C Control Module Technicals
  • ALSTOM N895313512X Digital Output Module
  • ALSTOM P70035W82V Feeder Protection Relay
  • ALSTOM N897164624A Digital Input Module
  • ALSTOM N897164611M Power Supply Module
  • ALSTOM N897164610L Communication Interface Module
  • ALSTOM N70032702L Protection Relay Module for Power Systems
  • ALSTOM MVAJ21L1GB0771B Voltage Protection Relay
  • ALSTOM MFAC34N1AA0001A Overcurrent Protection Relay
  • ALSTOM MCTI40N1AB0751G Current Differential Protection Relay
  • ALSTOM MCGG22L1CB0753E Overcurrent Protection Relay
  • ALSTOM MVAW 11B1AB0513A Trip Circuit Supervision Relay
  • ALSTOM MVTU 11K1CD0751G Voltage Transformer Supervision
  • ALSTOM MVAJ27L1FB0784D High Speed Tripping Relay Guide
  • ALSTOM MAVS01L1AB0501D Voltage Selection Relay Documentation
  • ALSTOM MVAW11B1AB9007A Trip Circuit Supervision Relay
  • ALSTOM MFAC14K1AA0001A Feeder Protection Relay
  • ALSTOM MCGG62N1CB0753F Generator Protection Relay
  • ALSTOM MAVS01L1AB0751D Protection Relay
  • ALSTOM PIB1201A 3BEC0067 Interface Module
  • ALSTOM V4555724-0100 Voltage Protection Relay
  • BENTLY 1900/65A-01-01-03-00-01 Monitor
  • BENTLY 3500/42-01-00 Proximitor Monitor
  • BENTLY 3500/54-03-00 Temperature Monitor
  • BENTLY 163179-02 Accelerometer
  • BENTLY 3500/94 145988 Display
  • Bently Nevada 1X35668 Replacement Internal Component Analysis
  • Bently Nevada 3500/22M 138607/01 Transient Data Interface
  • Bently Nevada 3500/40M 135489-04 Proximitor Monitor Module
  • Bently Nevada 3500/40M 125680-01 Proximitor Monitor
  • Bently Nevada 3500/15 127610-01 Power Supply Module
  • Bently Nevada 1900/65A-00-01-01-01-01 Machinery Monitor
  • Bently Nevada 3500/65 145988-02 Temperature Monitor
  • Bently Nevada 330876-03-50-00-00 Proximity Probe
  • BENTLY 3500/93 135785-02C System Display Module
  • BENTLY 3701/55 323174-01 ADAPT Input/Output Module
  • BENTLY 3500/42M 140734-99 Modification Module
  • BENTLY 3701/55 289761-01 ADAPT Emergency Shutdown Device
  • BENTLY 3500/42M 140734-02 Proximitor Seismic Monitor
  • BENTLY 3500/15 114M5330-01 Power Supply Module
  • BENTLY 3500/92 136180-01 Communication Gateway
  • BENTLY 3500/93 135799-01 LCD Display Module
  • BENTLY 3500/22 Transient Data Interface Module
  • BENTLY 9200-01-01-10-00 General Purpose Monitor
  • BENTLY 3500/65 145988-02 Temperature Monitor
  • BENTLY 1900/65A 172323-01 General Purpose Monitor
  • BENTLY 3500/22M 138607-01 Transient Data Interface
  • BENTLY 149986-01E 3300 XL 8mm Proximity Probe
  • BENTLY 1900/65A-01-01-03-00-01 General Purpose Monitor
  • BENTLY 136719-01 3500/92 Communication Gateway I/O
  • BENTLY 3500/22-01-01-00 Transient Data Interface Module
  • BENTLY 3500/22M 288055-01 Transient Data Interface
  • BENTLY 131151-01 3500/50 Tachometer I/O Module
  • BENTLY 1900/65-00-01-03-01-01 General Purpose Monitor
  • Bently Nevada 3500/54 133396-01 Overspeed Detection Monitor
  • Bently Nevada 3500/45 176449-04 Position Monitor
  • Bently Nevada 3500/42 140471-01 Proximitor Monitor
  • Bently Nevada 3500/94 147663-01 VGA Display Module
  • Bently Nevada 3500/42M 140482-01 Proximitor Monitor
  • BENTLY 3500/53 133396-01 Relay Module (Alternate Version)
  • BENTLY 3500/20 125744-01 Rack Interface Module
  • BENTLY 3500/53 133388-01 Relay Module
  • BENTLY 3500/15 114M5335-01 Power Supply Module
  • BENTLY 3500/40M 140734-01 Proximitor Monitor Module