Product Overview
In the field of railway signal control, how to use a flexible, scalable, and safety certified controller to cover various scenarios from simple relay points to complex interlocking stations has always been a core issue of concern for operators. ElectroLogIXS launched by KB Signaling ® VLC (Vital Logic Controller) is an integrated interlocking and signal control platform designed for this purpose. As a core member of the ElectroLogIXS product family, VLC integrates Vital logic processing, I/O control, communication management, and diagnostic functions into the same chassis, providing an integrated solution for roadside equipment control.
The positioning of VLC is very clear: it is a fully integrated, safety level Wayside Device Controller that can be configured as an interlocking control system or signal control system, enabling control of electric point machines, direct interface with encoded track circuits, and self proving lighting control of AC and DC signal lights.
Core competitiveness and product highlights
The reliability of VLC is based on long-term on-site verification - with over 25000 devices in service worldwide and over 20 years of safe and stable operation. Its main highlights include:
A self-contained interlocking and signaling solution: complete roadside control tasks can be completed without the need for external control units;
Flexible modular configuration: Available in nine slot, four slot, and single slot chassis, equipped with 10 application modules and 5 system modules. Application modules of the same type can be stacked and installed to meet I/O capacity requirements;
Easy incremental upgrade: All controllers use a unified third-generation security processing module (VPM-3), with a smooth upgrade path;
Sharing modules and tools with other products: with ElectroLogIXS ® EC5, XP4, and VHLC products share hardware modules, design concepts, and programming tools, which can reduce design time, simplify installation and maintenance, reduce spare parts inventory, and improve training efficiency;
Integrated PTC WIU function: natively supports the roadside interface unit function required for train active protection (PTC).
Flexibility and Scalability Design
The "Flexible" feature of VLC is reflected in its plug and play module combination method. Engineering personnel only need to install the required application modules and system modules in the chassis to customize configurations for different station sizes. The stacking of multiple application modules of the same type allows for on-demand expansion of I/O capacity, avoiding overinvestment.
In terms of scalability, with the help of the VPM-3 secure processor, multiple ElectroLogIXS system units can be interconnected through a vital link, connecting up to 32 remote units - including other VLC, VHLC, XP4, EC5 controllers, ElectroBlox I/O modules, and track occupancy detection devices such as axis counters. This architecture enables large-scale interlocking networks to be deployed in a distributed manner while maintaining the integrity of security information.
System architecture and human-machine interface
The system architecture of VLC consists of the following components: chassis backplane assembly, control display unit (CDU), system module, application module, and personality module with high-density wiring terminals, used to hard wire the system to roadside signal equipment and track circuits. All modules are equipped with health status and function indicator lights on the front for real-time monitoring of I/O signals during operation.
In terms of human-machine interface, VLC provides a two-tier solution:
Durable Control Display Unit (CDU): Suitable for direct operation in harsh on-site environments;
Web GUI graphical interface: can be accessed through any networked web device, supports system installation, maintenance, and troubleshooting, and can access status, diagnostics, log files, and configuration information through system management protocols such as SNMP, SCP, SSH, Telnet, FTP, SNTP, etc.
This dual interface design of "local+remote" significantly reduces the technical threshold for on-site maintenance.

Advanced roadside signal function
VLC has made significant design optimizations in terms of availability and maintainability:
Graceful Degradation: A single I/O failure will not affect other operating modules, ensuring maximum overall system availability;
One person digital setting: The parameter setting of signal lights and track circuits can be completed by a single person, reducing the workload of debugging;
Simplified diagnosis and recording function: The built-in event recorder can store 100000 events, 5000 error records, and 1000 configuration variables, providing complete data for fault tracing.
Application development toolchain
The application logic of VLC is implemented through KB Signaling's LogicStation ™ Development kit completed. The suite includes file management, compiler for generating application equations based on relay logic diagram, verification tools for verifying compiled files, and simulator for debugging applications before installation. It is worth noting that LogicStation is also applicable to ElectroLogIXS XP4, VHLC, and Electro Code 5 products, which means that engineers only need to master one set of tools to cover multiple product lines, significantly reducing learning and training costs.
Safety Certification (CENELEC)
For safety critical systems, independent certification is an important basis for procurement decisions. The configuration provided by VLC has been independently evaluated and fully complies with European safety standards:
EN 50129: Safety requirements for railway signal safety electronic systems;
EN 50128: Railway software safety integrity requirements;
EN 50126: Railway System RAMS (Reliability, Availability, Maintainability, Safety) Lifecycle Management.
Communication and Protocol Support
VLC is equipped with 2 Ethernet ports and up to 4 serial ports, supporting the industry's widest range of critical communication standards:
Secure Link Protocol: RP2000, RP2009, FSFB/2, up to 32 remote secure links;
Non secure protocols: Genisys, ATCS, BCS, ARES, SCS-128, UCE, LCP, Modbus, CTC over ITCM, providing 2 links each with 1000 controls/1000 representation, and 1 link with 128 controls/128 representation;
PTC protocol: EMP Class D, wireless crossing ITCS, Capable of generating fully compliant PTC messages;
Locomotive signal: up to 2 16 channel locomotive signal control modules, with code rate controlled by the application.
Quick overview of key specifications
Working voltage 9.5-16.5 V DC
The cycle time safety equation is stable within 250ms; Non safety equation stable within 100ms
Logical equations can have up to 10000 safe equations and 10000 non safe equations
127 safe timers and 1023 non safe timers
512 safety recorders for each recorder/temporary variable; 4096 secure temporary variables each
Up to 8 24000 foot track circuits (3 Ω/thousand feet ballast impedance) can be installed on the track circuit, and each circuit can be equipped with locomotive signal output
Up to 9 self proving direct drive modules with 110 VAC/12 VDC for lighting control (8 lights per AC module and 16 lights per DC module); 6 stabilized DC modules (6 lights per module)
Up to 9 12/24/50 V modules (8 inputs and 6 outputs per module) for safety I/O, with an additional 4 redundant inputs/4 redundant outputs configuration