Core parameters and characteristics of the product
1. Basic hardware specifications
Category detailed parameters
Channel configurations MSO54 (4 channels), MSO56 (6 channels), and MSO58 (8 channels) all support FlexChannel technology, and a single channel is compatible with:
-Analog probe (TekVPI) ® Or BNC interface)
-8-channel digital probe (TLP058 FlexChannel Logic Probe)
Bandwidth range: Basic bandwidth of 350 MHz (default), supports upgrades: 500 MHz, 1 GHz, 2 GHz (requires corresponding bandwidth options, such as SUP5-BW3T54)
Sampling performance with a maximum sampling rate of 6.25 GS/s, supporting real-time sampling, interpolation real-time sampling, and equivalent time sampling (only applicable to repetitive signals)
Record length standard 62.5 M points/channel, optional upgrade to 125 M points/channel (options 5-RL-125M/SUP5-RL-125M)
15.6-inch HD capacitive touch screen (1920 × 1080 pixels) with optimized touch operation logic, supporting multi finger gestures, double-click configuration, etc
Capture capability up to 500000 waveforms per second, FastAcq mode can reduce waveform acquisition dead time and accurately capture transient events such as spikes and short pulses
Optional integrated functions include a 50 MHz arbitrary function generator (AFG), digital multimeter (DVM), and trigger frequency counter
2. Core technological advantages
FlexChannel technology: No need to replace hardware modules, single channel can switch between analog/digital signal acquisition, flexible adaptation to mixed signal debugging scenarios.
Multidimensional triggering system: covering basic triggering, advanced triggering, and bus triggering, it can accurately capture target signal events.
Unrestricted waveform display: Supports unlimited display of mathematical waveforms, reference waveforms, and bus waveforms (limited by system memory).
TekSecure security feature: supports secure memory erasure and protects sensitive test data.

Accessories and optional features
1. Standard accessories (included with the box)
Accessory Name Quantity Specification/Purpose Tektronix Model
Installation and Safety Manual 1 Instrument Installation and Safety Operation Guide 071-3514-xx
Passive voltage probe, one 350/500 MHz model per channel, equipped with TPP0500B (500 MHz bandwidth); 1/2 GHz model with TPP1000 (1 GHz bandwidth) TPP0500B, TPP1000
Front panel cover 1 protects the instrument front panel interface 200-5406-xx
Accessory bag 1 stores small accessories, attached to the front panel cover 016-2106-xx
Wired USB Mouse 1 Auxiliary Operation Interface 119-7054-xx
The voltage standard for power cord 1 to adapt to the corresponding region depends on the region
Calibration Certificate 1: Instrument Factory Calibration Certificate N/A
2. Recommended accessories (optional)
Accessory name, purpose, model/specification
Hard transport box instrument transportation protection HC5
Rack installation kit installs the instrument onto a standard equipment rack (requiring 7U space) RM5
Mini keyboard for convenient text/parameter input 119-7275-xx
GPIB-USB adapter implements GPIB interface extension TEK-USB-488
TekVPI to BNC adapter compatible with BNC probe and TekVPI interface TPA-BNC
Off ramp pulse generator assisted multi-channel off ramp calibration 067-1686-xx
High voltage differential probe for high voltage signal measurement (such as THDP0100: ± 6 kV, 100 MHz) THDP0100, THDP0200, etc
Current probe current signal measurement (such as TCP0020: 50 MHz, 20 A AC/DC) TCP0020, TCP0030A, etc
3. Core optional function options
Function Category Options Model Details Features
Arbitrary Function Generator (AFG) 5-AFG (pre installed), SUP5-AFG (upgraded) - waveform types: sine, square wave, pulse, ramp, etc. 13 preset waveforms+arbitrary waveform
-Maximum frequency: 50 MHz (sine wave)
-Maximum output amplitude: 5 Vp-p (high impedance load)
-Sampling rate: 250 MS/s, any waveform recording length of 128K samples
Advanced Jitter Analysis (DJA) 5-DJA (pre installed), SUP5-DJA (upgraded) - supports 30+industry standard jitter and eye chart measurements: TIE TJ@BER 、 DDJ、DCD、 Eye height, eye width, Q factor, etc
-Generate analysis views such as jitter summary table, bathtub curve, eye diagram, etc
Bandwidth upgrade SUP5-BW3T54 (4-channel 350 → 500 MHz), SUP5-BW3T104 (4-channel 350 → 1 GHz), SUP5-BW3T204 (4-channel 350 → 2 GHz), etc. - Partial upgrades only require a license (such as 350 → 500 MHz), while high bandwidth upgrades need to be sent back to the service center for hardware replacement
-Upgrade with calibration data and new front-end bandwidth labels
Serial bus triggering and analysis -5-SRAUDIO (audio bus), 5-SRAUTO (car bus), 5-SRCOMP (computer bus), 5-SRENET (Ethernet), 5-SREMBD (embedded bus), 5-SRUSB2 (USB 2.0) - supports buses: I2S, LJ, RJ, TDM (audio); CAN, LIN, FlexRay (automotive); RS-232/422/485/UART (computer); 10BASE-T/100BASE-T (Ethernet); I2C, SPI (embedded); USB 2.0 LS/FS/HS
Record length upgrade 5-RL-125M (pre installed), SUP5-RL-125M (upgraded) will increase the default 62.5M point/channel record length to 125M point/channel, which can capture more waveform data points
Email:wang@kongjiangauto.com